Small Fatigue Crack Measurement and Crack Growth Characteristics for Smooth and Notch Specimens (평활 및 노치재의 미소피로균열측정과 성장특성)

  • 이종형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2145-2152
    • /
    • 1993
  • The objective of this paper is to examine the detection limit, growth characteristics and notch curvature radius in short crack problem. Measurement techniques such as ultrasonic method and back-face strain compliance method were adopted. The fatigue crack growth rate of the short crack is slower than that of a long crack for a notched specimen. The characteristic of crack growth and crack closure is same as the case of a delay of crack growth caused by constant amplitude load for an ideal crack or single peak overload for a fatigue crack. The short crack is detected effectively by ultrasonic method. A short surface crack occurs in the middle of specimen thickness and is transient to a through crack depth is larger than the notch curvature radius.

Measurement of the Ultrasonic Longitudinal Wave Velocities in Thin Plate (얇은 판재에서의 초음파 종파속도 측정)

  • 안봉영;이승석;이재옥
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2181-2188
    • /
    • 1991
  • The ultrasonic longitudinal wave velocities propagating normal to the surface in thin plates were measured with the amplitude spectrum method. The accuracy of the velocity measurement in o.5mm thick plates was 0.1%. In 4.239mm thick plate the phase velocities at the frequency band of 5MHz-15MHz were measured with the phase spectrum method and the amplitude spectrum method, and the velocity difference between two methods was less than 20m/s.

A Scalar Adaptive Filter Considering Acceleration for Navigation of UAV (무인기의 항법을 위한 가속도를 고려한 적응 스칼라 필터)

  • Lim, Jun-Kyu;Park, Chan-Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • This paper presents a novel scalar adaptive filter, which is reformulated by additional acceleration term. The filter continuously estimates three different kinds of covariance such as the measurement noise covariance, the velocity error covariance and the acceleration error covariance. For estimating three covariances, we use the innovation method for the measurement noise covariance and the least square method for other covariances. In order to verify the proposed filter performance compared with the conventional scalar adaptive filter, we make indoor experimental environment similar to outdoor test using the ultrasonic sensors instead of GPS. Experimental results show that the proposed filter has better position accuracy than the traditional scalar adaptive filter.

A Study of Small Fatigue Crack Measurement and Crack Growth Characteristics (미소균열측정과 성장특성에 관한 연구)

  • Lee, Jong-Hyung;So, Yoon-Sub;Kim, Yun-Gon;Lim, Chun-Kyoo;Lee, Sang-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • The objective of this paper is to examine the detection limit, growth characteristics and notch curvature radius in short crack problem. Measurement techniques such as ultrasonic method and back-face strain compliance method were adapted. The fatigue crack growth rate of the short crack is slower than that of a long crack for a notched specimen. The short crack is detected effectively by ultrasonic method. A short surface crack occurs in the middle of specimen thickness and is transient to a through crack when maximum crack depth is larger than the notch curvature radius.

  • PDF

Automatic Detection Method of the Region of Interest in the Measurement of Bone Mineral Density by Ultrasound Imaging (초음파 영상에 의한 골밀도 측정에서 관심영역의 자동 검출방법)

  • 신정식;안중환;한은옥;김형준;한승무
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.200-208
    • /
    • 2004
  • In ultrasonic bone densitometry, the positioning of measurement site is decisive in precision and reproducibility. In this study, automatic Region of Interest (ROI) detection algorithm is suggested and adopted the method using the local minimum value by ultrasonic image. The preprocess before the local minimum method extracts out the bone area and calculates the geometrical information of bone. The developed ROI detection algorithm was applied to the clinical test for the subject of 305 female patients in the range of 22-88 years old. As the results, the accuracy of the algorithm was shown to be 98.3%. It was also found that bone density parameter was significantly correlated with age(r=0.85, p<0.0001).

Evaluation of Ultrasonic Multiple Scattering Method to Improve the Accuracy of Fine Dust Measurement (비산먼지 측정 정확도 개선을 위한 시뮬레이션 초음파 다중 산란 알고리즘 검증)

  • Woo, Ukyong;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.119-128
    • /
    • 2020
  • An ultrasonic multiple scattering simulation using cross-section of fine dust particles were proposed. These days, along with awareness of air pollution, social interest in fine dust is increasing. In the construction field, awareness of fine dust is increasing, and research on preparing various countermeasures is underway. The light scattering method fine dust meter currently in use is affected by environmental factors such as relative humidity, and reliability problems in terms of accuracy are continuously reported. However, the transmission of ultrasonic waves can directly reflect the physical change of the medium based on the mechanical wave. Using these advantages of ultrasonic waves, fine dust measurement simulation was performed using the scattering cross section and ultrasonic multiple scattering theory. The shape data of the fine dust particles were collected using a SEM (Scanning Electron Microscope), and a cross-section according to the fine dust particles was derived through numerical analysis. As a result of signal processing, the error for the number density corresponding to each cross-section is minimum 19, maximum 3455.

A Study on the Aluminum Wire Bondingby Using Ultrasonic Vibrator (초음파 진동자를 이용한 알루미늄 와이어 용접에 관한 연구)

  • 김희수;이건복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.571-576
    • /
    • 1994
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. In order to improve the currently used wire bonding machine using ultrasonic energy, technical accumulation is needed steadily through development of exciting device of ultrasonic composed of piezoelectic vibrator and horn. This study investigates the design conditions affecting the dynamic characteristics through the theoretical and experimental analysis of piezoelectric vibrator and horn, The study conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. In theoretical model, the integrated modeling is conducted via a combination of dynamic identification of piezoelectric vibrator and theoretical analysis of horn. Hence comparison is made for theoretical and experimental results of the dynamic characteristics of the ultrasonic transducer composed of piezoelectric vibrator and horn. Form the results of this study we develop the design technique of ultrasonic transducer using dynamic characteristic analysis and propose the possibility of ultrasonic welding considering the optimal condition of the natural frequency and vibration mode of horn.

  • PDF

Performance Evaluation of the Velocity Profile Integration for the Multi-Path Ultrasonic Flowmeter in Symmetric & Asymmetric Flow Field (대칭 및 비대칭 유동장에서 다회선 초음파 유량계의 유속분포 적분 방법 평가)

  • Kim, Joo-Young;Kim, Kyung-Jin;Park, Sung-Ha
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.370-377
    • /
    • 2002
  • Generally, the system of calculation for the multi-path ultrasonic flow meters can be divided into two methods by how to get the mean velocity, namely, weighting and direct method. Weighting-method derive the mean velocity through modeling in theoretical velocity profile. Direct-method derive the mean velocity though actual flow distribution. The system of calculation varies with maker's transducer configuration and integration method. Each system has merits and demerits. This paper describes the system of integration that calculates line velocity over cross-section of the circular pipe. Flow rate mr discussed in this paper is a difference between theoretical flow rate and integrated flow rate according to values of Reynolds number in symmetric flow field or theoretical flow rate and integrated flow rate according to rotated model in asymmetric flow field.

  • PDF

Measurement Method of Ultrasonic Velocity by Correction of Non-Linear Propagation Delay (비선형 전파지연의 보정에 의한 음속의 측정법)

  • Ko, Duck-Young;Choi, Jong-Ho;Lee, Jong-Arc
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.98-105
    • /
    • 1989
  • To characterize the biological tissue, the new method to measure the ultrasonic velocity is presented in this paper. The influence of the dispersion effect on the estimation of the ultrasonic velocity is mostly neglected. A more efficient method determining the minimum phase spectrum is developed to characterize the frequency dispersion form the spectral magnitude function. To eliminate the frequency dispersion, the signal-decomposition method is also proposed. Computer simulations are performed to verify the algorithms.

  • PDF

A Region Search Algorithm and Improved Environment Map Building for Mobile Robot Navigation

  • Jin, Kwang-Sik;Jung, Suk-Yoon;Son, Jung-Su;Yoon, Tae-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.71.1-71
    • /
    • 2001
  • In this paper, an improved method of environment map building and a region search algorithm for mobile robot are presented. For the environment map building of mobile robot, measurement data of ultrasonic sensors and certainty grid representation is usually used. In this case, inaccuracies due to the uncertainty of ultrasonic data are included in the map. In order to solve this problem, an environment map building method using a Bayesian model was proposed previously[5]. In this study, we present an improved method of probability map building that uses infrared sensors and shift division Gaussian probability distribution with the existing Bayesian update method using ultrasonic sensors. Also, a region search algorithm for ...

  • PDF