• Title/Summary/Keyword: Ultrasonic energy

Search Result 655, Processing Time 0.028 seconds

The Estimation of Neutron Fluence in Nuclear Reactor Vessel Materials by the Analysis of Ultrasonic Characteristics (초음파특성 분석에 의한 원자로 재료의 중성자 조사량 예측)

  • Lee, Sam-Lai;Chang, Kee-Ok;Kim, Byoung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.307-312
    • /
    • 2001
  • Ultrasonic signals from Charpy impact test specimen have been analyzed in order to evaluate the integrity of reactor pressure vessel. Base and weld metal that were extracted from reactor vessel doting plant outages according to the schedule of the surveillance test required by the related regulations have been used and the ultrasonic test parameters including velocity, attenuation, etc. showed a close correlations with the amount of neutron irradiation for base metal, relatively homogeneous materials. This result showed certain possibility where a nondestructive method could be used to predict the fluence of the Irradiation due to neutron in nuclear reactor vessel materials.

  • PDF

Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor (초음파센서를 이용한 냉중성자원 수직공 형상측정)

  • Park, Guk-Nam;Choe, Chang-Ung;Sim, Cheol-Mu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

A Study of the Couplant Effects on Contact Ultrasonic Testing

  • Kim, Young-H.;Song, Sung-Jin;Lee, Sung-Sik;Lee, Jeong-Ki;Hong, Soon-Shin;Eom, Heung-Seop
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.621-626
    • /
    • 2002
  • The amplitude of a back-wall echo depends on the reflection coefficient of the interface between a transducer and a test material when using contact pulse-echo ultrasonic testing. A couplant is used to transmit ultrasonic energy across the interface, but has an influence on the amplitude of the pulse-echo signal. To investigate the couplant effect on pulse-echo ultrasonic testing, back-wall echoes are measured by using various couplants made of water and glycerine in a carbon and austenitic stainless steel specimens. The amplitude of the first back-wall echo and the apparent attenuation coefficient increases with the acoustic impedance of the couplant. The couplant having a higher value of the transmission coefficient is more effective for flaw detection. The reflection coefficient should be known in order to measure the attenuation coefficient of the test material.

The Synthesis of Lithium Lanthanum Titanium Oxide for Solid Electrolyte via Ultrasonic Spray Pyrolysis (초음파 분무 열분해법을 이용한 고체전해질용 Lithium Lanthanum Titanium Oxide 제조)

  • Jaeseok, Roh;MinHo, Yang;Kun-Jae, Lee
    • Journal of Powder Materials
    • /
    • v.29 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Lithium lanthanum titanium oxide (LLTO) is a promising ceramic electrolyte because of its high ionic conductivity at room temperature, low electrical conductivity, and outstanding physical properties. Several routes for the synthesis of bulk LLTO are known, in particular, solid-state synthesis and sol-gel method. However, the extremely low ionic conductivity of LLTO at grain boundaries is one of the major problems for practical applications. To diminish the grain boundary effect, the structure of LLTO is tuned to nanoscale morphology with structures of different dimensionalities (0D spheres, and 1D tubes and wires); this strategy has great potential to enhance the ion conduction by intensifying Li diffusion and minimizing the grain boundary resistance. Therefore, in this work, 0D spherical LLTO is synthesized using ultrasonic spray pyrolysis (USP). The USP method primarily yields spherical particles from the droplets generated by ultrasonic waves passed through several heating zones. LLTO is synthesized using USP, and the effects of each precursor and their mechanisms as well as synthesis parameters are analyzed and discussed to optimize the synthesis. The phase structure of the obtained materials is analyzed using X-ray diffraction, and their morphology and particle size are analyzed using field-emission scanning electron microscopy.

A study on the fabrication of lithium carbonation powder by gas-liquid reaction using ultrasonic energy (탄산리튬 분말 제조에 있어서 초음파 에너지를 적용한 기액반응에 관한 연구)

  • Kim, Dae-Weon;Kim, Bo-Ram;Choi, Hee-Lack
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2020
  • In the previous study, we reported the result to prepare lithium carbonate powder from various lithium-contained solution. Therefore, using the lithium hydroxide solution, it is conformed that the reaction could occur thermodynamically, and the recovery rate of lithium was 89.4 %. In this study, we carried out the experiment to prepare lithium carbonate powder through gas-liquid reactions with lithium hydroxide solution and CO2 gas using ultrasound energy. In case ultrasonic energy is applied to the reaction of lithium carbonate, the recovery rate of lithium at room temperature was approximately 83.8 %, and the recovery rate of lithium was greatly increased to approximately 99.9 % at 60℃ reaction temperature. And when ultrasonic energy is not applied, the particle size of lithium carbonate powder was 7.7 ㎛ in D50. But the particle size of lithium carbonate powder was significantly reduced to 8.4 ㎛ in D50 under the influence of ultrasonic.

Design Space Exploration of Many-Core Processors for Ultrasonic Image Processing at Different Resolutions (다양한 해상도의 초음파 영상처리를 위한 매니코어 프로세서의 디자인 공간 탐색)

  • Kang, Sung-Mo;Kim, Jong-Myon
    • The KIPS Transactions:PartA
    • /
    • v.19A no.3
    • /
    • pp.121-128
    • /
    • 2012
  • This paper explores the optimal processing element (PE) configuration for ultrasonic image processing at different resolutions ($256{\times}256$, $768{\times}1,024$, and $1,024{\times}1,280$). To determine the optimal PE configuration, this paper evaluates the impacts of a data-per-processing element (DPE) ratio that is defined as the amount of image data directly mapped to each PE on system performance and both energy and area efficiencies using architectural and workload simulations. This paper illustrates the correlation between DPE ratio and PE architecture for a target implementation in 130nm technology. To identify the most efficient PE structure, seven different PE configurations were simulated for ultrasonic image processing. Experimental results indicate that the highest energy efficiencies were achieved at PEs=1,024, 4,096, and 16,384 for ultrasonic images at $256{\times}256$, $768{\times}1,024$, $1,024{\times}1,280$ resolutions, respectively. Furthermore, the maximum area efficiencies were yielded at PEs=256 ($256{\times}256$ image) and 4,096 ($768{\times}1,024$ and $1,024{\times}1,280$ images), respectively.

A Reliability Study of the Phased Array Ultrasonic Testing: Case Study for the Composite Blades of Wind Power Generation (위상배열 초음파 탐지검사의 신뢰성에 관한 연구: 풍력발전기 복합소재 블레이드 사례연구)

  • Kang, Byung Kwon;Lim, Ik Sung;Koo, Ilseob
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.338-346
    • /
    • 2016
  • Purpose: The purpose of this research is to improve the reliability of the composite material blades used for the wind power generator, by applying the phased array ultrasonic testing technique out of the many nondestructive test into the blades. Method: The wind power generation composite blades are used, as a case study, in order to evaluate the reliability of the phased array ultrasonic testing technique. Defects that are most likely occurred in the field are injected into the different locations of the three different types of artificial test pieces and then phased array ultrasonic testing technique are applied to evaluate the reliability of its effectiveness. Result: As a result of the analysis of the defect signals by applying the A scan and B scan simultaneously, depth and width of the defect could be obtained. An area of defect was proportional to the amount of energy by color in B scan image. The larger amount of energy, reflected amount of energy was appeared in the order of red, orange, yellow, blue color. Conclusion: The most reliable testing method to detect the defect in composite blades for wind power generation is considered to be the combination of the other destructive testing technique with the phased array ultrasonic testing since the PAUT alone could not detect all range of the defects in the blades.

A Development of an Array Guided Wave Ultrasonic Testing System for pipe inspection (배관 진단을 위한 배열형 유도초음파 검사시스템 개발)

  • Cho, Hyun-Joon;Lee, Dong-Hoon;Kang, To;Park, Jin-Ho;Han, Seong-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.29-35
    • /
    • 2015
  • Pipes, commonly used in energy and petrochemical facilities, have various types of defects induced by diverse factors and this is often issued in NDE society. Ultrasonic guided wave inspection method are normally adopted to insure the healthiness of industry pipes. Recently, ultrasonic guided wave inspection is shifted to adopt arrayed probes and system. And here we developed an array guided wave ultrasonic testing system can adapt arrayed probes and focusing methods. In this paper, an array guided wave ultrasonic testing system is presented including a transmitting focusing technique and flaw signal level enhancement.

Production of Lard Based Biodiesel Using Ultrasound Assisted Trans-Esterification (초음파가 도입된 전이에스테르화 반응을 이용한 돈지원료 바이오디젤의 제조)

  • Cho, Hae-Jin;Lee, Seung-Bum;Lee, Jae-Dong
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.155-160
    • /
    • 2011
  • An animal fat is an attractive biodiesel energy source for its high stability against oxidation and low incomplete combustion ratio due to the high heating value and cetane value. However, it requires a refinery process because of the high content of saturated acid and impurity which increas the boiling point. In this study, the optimum biodiesel synthetic process of lard is suggested. Indeed, we demonstrate new biodiesel production processes to alter conventional process of heating and mixing by applying ultrasonic energy. While the optimum reaction temperature and mole ratio of methanol and lard, when using conventional mixing and heating process, were $55^{\circ}C$ and 12, respectively, the reaction time were reduced to 30 minutes by applying ultrasonic irradiation power of 500 W. The new process applying ultrasonic irradiation yielded synthetic biodiesel properties as followings: 3.34 cP of the viscosity, 37.0 MJ/kg of the caloric value and below 0.25 mgKOH/g of the acidic value, which satisfy biodiesel quality criteria.

Detection of a Surface-Breaking Crack Using the Surface Wave of a Laser Ultrasound (레이저 초음파의 표면파를 이용한 표면결함 측정)

  • Park, Seung-Kyu;Jung, Hyun-Kyu;Baik, Sung-Hoon;Lim, Chang-Hwan;Joo, Young-Sang;Kang, Young-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.84-89
    • /
    • 2006
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasounds by using laser beams. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this paper, we have investigated the detection techniques of a surface-breaking crack by using the laser ultrasonic surface waves. A crack acts as a low pass filter whose cut-off frequency is lowered in proportion to the depth of a crack. And, the center frequency value of a spectrum is decreased in proportion to the depth of a crack. In this paper, we extracted the crack information by using the frequency attenuation from the normalized transfer function spectrum of a surface-breaking crack. Also, we effectively measured the crack depth by using the decreasing value of the center frequency from a crack passed ultrasonic signal. The proposed measuring techniques of crack depths provided more precise information than the amplitude measuring technique.