• Title/Summary/Keyword: Ultrasonic device

Search Result 314, Processing Time 0.029 seconds

Developement of Ultrasonic Handy Scanner for Welding Inspection (초음파를 이용한 용접부 핸디 스캔 검사기 개발)

  • Kang, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.14-18
    • /
    • 2005
  • The ultrasonic handy scanner to be developed in this research is a nondestructive inspection equipment with various facility. The ultrasonic inspection is the technique area which apply range is increasing greatly with IT. The purpose of this research is development of a ultrasonic handy scan inspection device with the utility in a work spot. The ultrasonic handy scanner to be developed with portability in this research is able to carry out the spot inspection. It can contribute to the quality improvement, cost reduction and safety design.

Development of High Frequency pMUT Based on Sputtered PZT

  • Lim, Un-Hyun;Yoo, Jin-Hee;Kondalkar, Vijay;Lee, Keekeun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2434-2440
    • /
    • 2018
  • A new type of piezoelectric micromachined ultrasonic transducer (pMUT) with high resonant frequency was developed by using a thin lead zirconate titanate (PZT) as an insulation layer on a floating $10{\mu}m$ silicon membrane. The PZT insulation layer facilitated acoustic impedance matching at active pMUT, leading to a high performance in the acoustic conversion property compared with the transducer using $SiO_2$ insulation layer. The fabricated ultrasonic devices were wirelessly measured by connecting two identical acoustic transducers to two separate ports in a single network analyzer simultaneously. The acoustic wave emitted from a transducer induced a $3.16{\mu}W$ on the other side of the transducer at a distance of 2 cm. The transducer performances in terms of device diameters, PZT thickness, annealings, and different DC polings, etc. were investigated. COMSOL simulation was also performed to predict the device performances prior to fabrication. Based on the COMSOL simulation, the device was fabricated and the results were compared.

THE MEASUREMENT OF FAT THICKNESS IN LIVE CATTLE WITH AN ULTRASONIC DEVICE AS A PREDICTOR OF CARCASS COMPOSITION

  • Mitsuhashi, T.;Mitsumoto, M.;Yamashita, Y.;Ozawa, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.3 no.4
    • /
    • pp.263-267
    • /
    • 1990
  • The fat thicknesses of twenty-eight Japanese Black beef steers were measured with an ultrasonic device at eleven points on the cattle prior to slaughter and side dissection. The relation between live fat thickness and both weight and percentage of fat and lean in the carcass was examined. Fat thickness obtained from nine points of the chest, flank and rump regions was found to relate significantly (P<0.01) to both weight and percentage of fat. However, shoulder fat thickness measurements were not significantly related to the weight or percentage of fat or lean in the carcass. Addition of live fat thickness to animal age or live weight as an independent variable markedly improved the precision of multiple regression equations for predicting weight of fat and lean, and percentage of fat. In predicting the percentage of lean, both animal age and body weight were not employed in the multiple regression equation. The residual standard deviation for predicting percentage of fat and lean were 1.93 and 1.87, respectively. The ultrasonic measurement of fat thickness if supposed to be useful to the prediction of carcass composition of beef cattle.

Development of a Ultrasonic System for Nano-Surface Reformation Process

  • Kim, Hyunse;Lim, Euisu;Park, Jong-Kweon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.4
    • /
    • pp.365-370
    • /
    • 2017
  • In this article, a 20 kHz Titanium (Ti) ultrasonic waveguide system for a nano-surface reformation process was designed and fabricated. First, finite element analysis using ANSYS software was performed to find the optimal dimensions. The obtained anti-resonance frequency for the Ti transducer with the piezoelectric device was 20.0 kHz, which value agreed well with the experiment result of 20.1 kHz (0.5% error). To test the system, chromium molybdenum steel (SCM) 435 was chosen as a test-piece. The result proved that the reformed depth was $36{\mu}m$. In addition, hardness was measured before and after the process. The value was changed from 14 HRC to 21 HRC, which is 50% increasing rate. Finally, the friction coefficient test result showed that the surface coefficient was reduced from 0.14 to 0.10 (28.6% reduction). Based on the results, the Ti ultrasonic equipment is regarded as a useful device for nano-scale surface reformation.

Fabrication and Characteristics of Flat-type $L_{-}$-$B_{8}$ Mode Ultrasonic Motors (평판형 종($L_{-}$-굴곡($B_{8}$)모드 초음파 전동기의 제작과 특성)

  • U, Sang-Ho;Lee, Eun-Hak;Kim, Jin-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.292-297
    • /
    • 2002
  • In this paper, a flat-type $L_{-}$-$B_{8}$ mode Ultrasonic Motor[USM] having the size of 80 x 20 x ${1.5}mm^3$($l{\times}\omega{\times}t$) was designed and fabricated to examine the characteristics of an ultrasonic vibration. We used ANSYS simulation program based on FEM to get the optimum design of this USM. As results of experiment, the fastest speed of revolution(v), the maximum torque(T) and the efficiency(n) were 37.5cm/s, 5.0 mN.m and 1.17% when 27.9KHz, 150N, 50V were applied respectively. And this flat-type $L_{-}$-$B_{8}$ mode USM could be controlled the speed of rotor revolution by applied voltage, frequency and pre-load of rotor as well as showed the characteristics of typical drooping torque-speed, large torque and high speed. So, we think that this flat-type $L_{-}$-$B_{8}$ mode USM has characteristics of enough torque and velocity to be usable for applications in forwarding device of an electric card or a paper, etc.

A Study on Effectiveness of Application of the IEC 61689 Standard to Ultrasonic Physiotherapy Systems with Frequency Range over 5MHz (5MHz 초과 초음파자극기에 대한 IEC 61689 규격 적용의 유효성에 관한 연구)

  • Youn, Ju-Shin;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.69-78
    • /
    • 2015
  • Ultrasonic physiotherapy systems should comply with IEC 60601-2-5(particular requirements for safety of ultrasonic physiotherapy equipment) standard for safety of patients and clinical performances. One of the most important parameters in the standard is the effective radiating area ($A_{ER}$). It has to be measured in accordance with IEC 61689 (field specifications and methods of measurement in the frequency range 0.5MHz to 5MHz). Typical ultrasonic physiotherapy system works in the frequency range 1MHz ~ 3MHz to comply with the IEC 61689. However, ultrasonic physiotherapy system using frequencies over 5MHz is out of the IEC 61689's scope. That is, even if such ultrasonic physiotherapy systems are developed by demands of the market, there is no standard to apply. It is the motivation for this study. Whereas there are other parameters to be considered, this study focuses on the effective radiating area and shows effectiveness of applying IEC 61689 in measuring effective radiating area of ultrasonic physiotherapy systems using frequency range over 5MHz by comparing the results of computer simulation and experiment. Results of this study shows that applying the IEC 61689 standard to ultrasonic physiotherapy system using frequency range over 5MHz is possible.

Display of Irradiation Location of Ultrasonic Beauty Device Using AR Scheme (증강현실 기법을 이용한 초음파 미용기의 조사 위치 표시)

  • Kang, Moon-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.25-31
    • /
    • 2020
  • In this study, for the safe use of a portable ultrasonic skin-beauty device, an android app was developed to show the irradiation locations of focused ultrasound to a user through augmented reality (AR) and enable stable self-surgery. The utility of the app was assessed through testing. While the user is making a facial treatment with the beauty device, the user's face and the ultrasonic irradiation location on the face are detected in real-time with a smart-phone camera. The irradiation location is then indicated on the face image and shown to the user so that excessive ultrasound is not irradiated to the same area during treatment. To this end, ML-Kit is used to detect the user's face landmarks in real-time, and they are compared with a reference face model to estimate the pose of the face, such as rotation and movement. After mounting a LED on the ultrasonic irradiation part of the device and operating the LED during irradiation, the LED light was searched to find the position of the ultrasonic irradiation on the smart-phone screen, and the irradiation position was registered and displayed on the face image based on the estimated face pose. Each task performed in the app was implemented through the thread and the timer, and all tasks were executed within 75 ms. The test results showed that the time taken to register and display 120 ultrasound irradiation positions was less than 25ms, and the display accuracy was within 20mm when the face did not rotate significantly.

Simulation of Ultrasonic Dry Cleaning for Semiconductor/display Device Application (반도체/디스플레이 소자용 초음파 건식세정 시뮬레이션 연구)

  • Yun, Eui-Jung;Lee, Gang-won;Kim, Chol-Ho;Lee, Seok-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.12
    • /
    • pp.1259-1263
    • /
    • 2004
  • In this paper, the optimum design of ultrasonic dry cleaning head was investigated. The transducer instead of mechanical dynamic structure was used to generate ultrasonic wave and the horn-shape amplifier was utilized to solve the energy decaying problem of ultrasonic wave with propagating it through the media. The analyses of ultrasonic wave and a fluid for the selected structure of a cleaning head were carried out using SYSNOISE and ANSYS simulators, respectively. Based on simulator results, the distance between a horn and the substrate of 4 mm and the horn diameter of 10 mm were determined to maximize the energy of ultrasonic waves. The cooling structure was also considered to reduce the heat from the transducer and the horn. The equivalent circuit for the fabricated horn was deduced from HP4194A impedance/gain/phase analyzer and the frequency of an ultrasonic wave of 20.25 kHz was confirmed using the parameters of the equivalent circuit.

Development of Robust Single Ultrasonic Module for Distance Measurement of Mobile Robot (이동로봇의 거리측정을 위한 고성능 일체형 초음파 모듈 개발)

  • Choi, Jong-Hoon;Shim, Hyeon-Min;Ryu, Je-Goon;Lee, Eung-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.418-420
    • /
    • 2005
  • This paper proposed ultrasonic distance measurement module development for correct distance detection with collision escaping or obstacle of mobile robot is traveling self-regulation. Representative ultrasonic module applied in existing was Polaroid company's 6500 series and Devantech company's SRF04/SRF08 series. This ultrasonic sensors are corrupted by systematic errors due mainly to the dependency of sound speed upon surrounding conditions and random errors of uncertain origin. Therefore Ultrasonic distance detecting means of error compensation method and high definition, narrow beam angle, board area distance detecting means to apply to ultrasonic mobile robot control urgently need. In this paper use internal type temperature compensation method to improve problem of ultrasonic distance measurement method instead of that volume that have shortcoming of used correct temperature compensation methods applied big addition device. Compensate error by environment change of temperature. Humidity density etc. and is applicable to mobile robot offering various interface and real-time processing developed possible distance measurement module.

  • PDF