A Study on Ultrasonic Vibration Cutting of Carbon Fiber Reinforced Plastics (탄소섬유강화 플라스틱의 초음파 진동절삭에 관한 연구)

  • 김정두;이은상;최인휴
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.24-33
    • /
    • 1994
  • The main applications of CFRP are sports, aerospace and general industrial uses including automobiles. As this application fields expands the opportunity of machining, but CFRP is difficult to cut because of delamination of the composites and the short tool life. In this paper, the machinability of multidirectional CFRP by means of ultrasonic vibration cutting, which has been verified experimentally investigated.The experimentally to be highly effective in view of cutting force and surface quality.

Application of Ultrasonic Vibration Energy on Eco-superfinishing and Surface Hardening Treatment of Cold Work Roller (초음파 진동에너지를 이용한 냉간 압연롤러 표면의 환경 친화적 초정밀 사상 및 표면 경화 처리 및 시험)

  • Y.S. Pyoun;Park, J.H.;C.H. Han;Park, Y.;I.S. Cho;N. Azuma;Lee, J.H.;Kim, C.S.;Park, C.H.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.39-39
    • /
    • 2002
  • In order to improve wear and fatigue resistance of the structural materials, especially cold work roller for 304 stainless steel, an eco-super-finishing and surface hardening treatment using ultrasonic vibration energy was developed and applied to the SKD-ll roller. The eco-super-finishing machine was designed and fabricated by DesignMecha Co, by its own technology. It was observed that the surface roughness, hardness and residual stress were changed from $Ra{\;}={\;}O.25\mu\textrm{m}$, Hv=710 and ${\sigma}$={\;}+400{\;}MPa{\;}to{\;}Ra{\;}={\;}0.165\mu\textrm{m}$, Hv = 1200 and ${\sigma}=-610$ MPa after 20 KHz micro-cold forging, which means almost equal to the 300 % improvement of life-time.

  • PDF

Application of Ultrasonic Technique for Early-Aged PC Beams in Field (초음파 탐사법의 긴장 전 PC보에 대한 현장적용)

  • Lee, Jun-Ki;Park, Sung-Woo;Yoon, Jung-Sup;Park, Chul-Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.589-592
    • /
    • 2008
  • Recently, as importance of quality control of the structure has been recognized, non-destructive testing, determining quality of the structure without damage, has been widely applied. However, its application has been primarily focused on laboratory development because variety of parameters in field has been not fully experienced and understood. This study aims to evaluate the field applicability of the ultrasonic testing method for PC beams. Material properties of 18 cylinders, cured in the same field condition, were measured up to 60 days and compared to those of the ultrasonic measurements from 34 PC beams in field before tensioning. Test results indicate that uni-axial strength and elastic modulus of PC beams can be predicted within reasonable range using the ultrasonic technique. However, it is also noted that considerations on field condition is required to increase the reliability of estimation.

  • PDF

An Estimation on the Field Application of Consolidants According to Rock Quality (암석 재질에 따른 보존처리제의 현장 적용성 평가)

  • Kim, Jae-Hwan;Han, Min-Su;Lee, Jang-Jon;Song, Chi-Young;Lee, Jae-Man;Kim, Min-Ji;Lee, Myeong-Sung
    • 보존과학연구
    • /
    • s.30
    • /
    • pp.79-91
    • /
    • 2009
  • Stone cultural heritages are mostly situated in field, so they are damaged from mechanical, chemical and biological weathering, and their degree of strength is also weaken. Therefore, the scientific conservation of the stone cultural heritages are necessary in order to the long-term maintenance and safety conservation. In this study, we attempt to estimate on the field application of consolidants which are Wacker OH 100, Remmers KSE 300 and 1T1G according to the quality of the rocks. Based on the ultrasonic velocity, conditions of weathering damage before treatment are mainly ranked completely weathering condition (CW) or partly highly weathering condition (HW). After the first treatment, weathering damage conditions are changed by the high weathering condition (HW). These results shows that the internal pores of stone are filled with consolidant materials, so average ultrasonic velocities increases after treatment. And Remmers KSE 300 which is consolidant material is highest rate of increase of average ultrasonic velocities.

  • PDF

THE EFFECT OF VARIOUS CEMENTS ON THE TENSILE STRENGTH OF A POST AND DIFFICULTIES OF ULTRASONIC POST REMOVAL (시멘트의 종류에 따른 포스트의 인장강도 및 제거의 난이도에 관한 연구)

  • Park, Jeong-Won;Roh, Byoung-Duck;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.181-192
    • /
    • 1997
  • The difficulty of endodontic retreatment depends on various factors and it is affected by retention of post. In this experiment, root canal therapy was done in extracted human teeth and cut into 10mm length from the root apex, and then cemented by zinc phosphate cement, Vitremer$^{(R)}$(glass ionomer) luting cement and Panavia 21$^{(R)}$(resin cement). Post preparation was done by #4 Parapost drill at 6mm length and cement was inserted by lentulo spiral. After 24 hours, tensile bond strength, post removal time was measured after the ultrasonic application and the separation site was measured. The following results were obtained. 1. In measuring tensile bond strength, there is no statistical difference between zinc phosphate cement and Panavia 21$^{(R)}$, but Vitremer$^{(R)}$ showed lower value compared with those two cements. (p<0.001) 2. When the post removal time was measured after ultrasonic application, significant different value in order of Panavia 21$^{(R)}$, zinc phosphate cement and Vitremer$^{(R)}$ was shown. (p<0.001) 3. As a result of examining the separating site of each cement, all 16 of zinc phosphate cement group showed the fracture site between cement and post, Vitremer$^{(R)}$ was 13/16, and Panavia 2$^{(R)}$ was 8/16. In case of tooth restoration using Parapost, the use of Panavia 21 showed good retention property than Vitremer$^{(R)}$, but when retreatment is needed the difficulty of post removal will be increased.

  • PDF

Development and Application of IoT-based Contactless Ultraosonic System (IoT 기반 비접촉 초음파 측정 시스템 개발 및 적용)

  • Kim, Jihwan;Hong, Jinyoung;Kim, Rrulri;Woo, Ukyong;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.70-79
    • /
    • 2020
  • The main objective of this research to develop an IoT based wireless contactless ultrasonic system (ICUS) and its application to concrete structure. The developed system consists of 16 mems, 2Mhz digitizer, amplifying circuit, FPGA, and wifi module, enabling to measure leaky surface waves from concrete specimens without physical coupling process and wires. Multi-channel analysis is performed to improve the accuracy of data analysis, and the velocity of leaky surface waves and acoustics are derived. Field inspection of railroad concrete sleepers is conducted to evaluate the performance of the system and to compare the results with conventional ultrasonic pulse velocity (UPV). As a result of the field inspection, UPV was limited to evaluate damages. This is because crack pattern of railroad sleepers is parallel to ultrasonic ray path and accessibility of the railroad at the field is disadvantageous to contact-based UPV. On the other hand, ICUS possibly detect the damages as reduction of dynamic modulus by up to 59% compared to non-damaged specimen.

Optimization of Electro-UV-Ultrasonic Complex Process for E. coli Disinfection using Box-Behnken Experiment (Box-Behnken법을 이용한 E. coli 소독에서 전기-UV-초음파 복합 공정의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.149-156
    • /
    • 2011
  • This experimental design and response surface methodology (RSM) have been applied to the investigation of the electro-UV-ultrasonic complex process for the disinfection of E. coli in the water. The disinfection reactions of electro-UV-ultrasonic process were mathematically described as a function of parameters power of electrolysis ($X_1$), UV ($X_2$), and ultrasonic process ($X_3$) being modeled by use of the Box-Behnken technique, which was used for fitting 2nd order response surface model. The application of RSM yielded the following regression equation, which is empirical relationship between the residual E. coli number (Ln CFU) in water and test variables in coded unit: residual E. coli number (Ln CFU) = 23.69 - 3.75 Electrolysis - 0.67 UV - 0.26 Ultrasonic - 0.16 Electrolysis UV + 0.05 Electrolysis Ultrasonic + 0.27 $Electrolysis^2$ + 0.14 $UV^2$ - 0.01 $Ultrasonic^2$). The model predictions agreed well with the experimentally observed result ($R^2$ = 0.983). Graphical 2D contour and 3D response surface plots were used to locate the optimum range. The estimated ridge of maximum response and optimal conditions for residual E. coli number (Ln CFU) using 'numerical optimization' of Design-Expert software were 1.47 Ln CFU/L and 6.94 W of electrolysis, 6.72 W of UV and 14.23 W of ultrasonic process. This study clearly showed that response surface methodology was one of the suitable methods to optimize the operating conditions and minimize the residual E. coli number of the complex disinfection.

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments

  • Unursaikhan, Otgonbayar;Lee, Jung-Seok;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.3
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. Methods: Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. Results: SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). Conclusions: The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.

Recognition resolution enhancement of ultrasonic sensors via multiple steps of transmitter voltages

  • Na, Seung-You;Park, Min-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.409-412
    • /
    • 1996
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensing are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of objects, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensor has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained with neither the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF