• Title/Summary/Keyword: Ultrasonic Transducer

Search Result 604, Processing Time 0.031 seconds

Nondestructive Evaluation of plate structures using the Ultrasonic Transducer OPMT (OPMT 초음파 트랜스듀서를 이용한 평판구조 이상진단)

  • Kim, Yoon-Young;Cho, Seung-Hyun;Lee, Ju-Seung;Sun, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.423-427
    • /
    • 2004
  • In this work, we propose a new ultrasonic damage inspection method in plate structures. The proposed method employs an OPMT (Orientation-adjustable Patch-type Magnetostrictive Transducer) in order to make the ultrasonic waves focused on the specific target point. For experiments, virtual grid points were set up at every 50 mm in an aluminum plate and two OPMTs were used for inspection. If there exists a crack in a plate, the reflected Lamb wave from the crack is measured in addition to the direct waves from the transmitting transducer to the receiving transducer.

  • PDF

A Study on Efficient Frequency Control of Transducer for Skin Treatment Using Multi-Frequency Ultrasound (멀티주파수 초음파를 사용하는 피부 치료기기 트랜스듀서의 효율적인 주파수 제어 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1038-1048
    • /
    • 2022
  • Ultrasound is one of the effective methods for skin treatment. The skin penetration depth of the ultrasound depends on the ultrasonic frequency, that is, when the ultrasonic frequency is high, the depth is shallow. We have developed a transducer which can generate effectively 3 different ultrasonic frequencies removing interference between 3 types of frequencies according to impedance matching technology. The generated powers of transducer are 40.67W at 3.MHz, 17.46W at 11.7 MHz, and 14.79W at 21.5 MHz. The signal interference between the three frequencies is designed so that they do not interfere with each other by separating the signals using the SPDT (Single Pole, Double Throw) switch. The developed hybrid ultrasound transducer can be applied in skin care or skin treatment and beauty therapy.

Design and Fabrication of a High Power Piezoelectric Ultrasonic Surgery Unit for Dental Implantation (치과 임플란트 수술용 고출력 초음파 수술기 설계 및 제작)

  • Kim, Na Ri;Jeon, Dae Woo;Kim, Jin Ho;Kim, Sun Woog;Hwang, Jong Hee;Lee, Jeong Bae;Choi, Sung Jae;Im, Dae Jin;Lee, Young Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.656-664
    • /
    • 2017
  • This paper presents the design and fabrication of a high power piezoelectric ultrasonic surgery unit for multi-purpose dental implantation. A conventional piezoelectric ultrasonic surgery units consists of a transducer and a tip. However, the drawback of this simple structure is that the output performance of the transducer considerably changes with the change of the tips. An ultrasonic surgery unit that has an additional booster between the transducer and the tip can solve this problem to some extent; for this, an optimal structural design for the transducer is required. We used the Bolted Langevin Transducer (BLT) as the basic transducer; it consists of piezoelectric ceramics and a metal body. It's structure was optimized using mathematical methods to determine the length and radius of the tail and head masses. Additionally, the booster was also subjected to the same methods. Using these mathematical methods, optimal results in terms of the resonance frequency (24.96 kHz), displacement ($14.27{\mu}m$), and pressure (2.8 MPa), could be obtained. The validity of this proposed surgery unit was confirmed experimentally, exhibiting a cutting force of around 7% higher than that of a conventional surgery unit.

Basic Experiment for Lamb Wave Focusing by Phased Magnetostrictive Transducers in a Plate (자기변형 트랜스듀서의 위상차를 이용한 평판에서의 Lamb파 집속 기초 실험)

  • Lee, Joo-Kyung;Kim, Hoe-Woong;Lee, Ho-Cheol;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.227-233
    • /
    • 2011
  • The ultrasonic guided wave phased array using magnetostrictive patch transducers is proposed. The magnetostrictive transducer has received much attention because it is cost-effective and capable to generate ultrasonic waves with a simple configuration. However, it has not been used for ultrasonic guided wave phased array applications until now. In this paper, we propose a magnetostrictive transducer based phased array system consisting of a multi-channel function generator, power amplifiers and Lamb wave magnetostrictive transducers. To check the performance of the ultrasonic guided wave phased array, several Lamb wave focusing experiments were carried out in an aluminum plate. The results demonstrated the capability of the developed array to focus the Lamb waves at specific target points.

Design of the Calibration System for Determining the Sensitivity of Ultrasonic Transducer (초음파 변환기의 감도 교정 시스템 구성)

  • 사공성대;조문재;최봉열
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • In this paper, a precise sensitivity measurement system of ultrasonic transducer in the frequency range from 1 MHz to 15 MHz, which can implement the reciprocity principle is constructed. All of the elements of this system such as the ultrasonic preamplifier, ultrasonic absorber, water tank, water degassing system, and four-axes translator and reflector are constructed. For the performance evaluation of the calibration system, a standard hydrophone precisely calibrated from PTB(Physikalisch Technische Bundesanstalt) in Germany are used. And the system parameters which affected the evaluation of the measurement accuracy and the reproducibility in various measuring conditions are considered. The measurement uncertainty of the calibration system is estimated within $\pm$ 2.0㏈.

  • PDF

Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer (초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석)

  • Nam, Young-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

A Study on Ultrasonic Transducer displacement generator by Frequency Phase modulation (주파수 위상 변조에 의한 초음파 탐촉자 변위 발생기에 관한 연구)

  • 김정래
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.3
    • /
    • pp.36-41
    • /
    • 2002
  • This study was carried out develope a ultrasonic transducer displacement generator through 26KHz and 38KHz of the frequency phase modulation on the ultrasonic transducer. This system was producted a power output generation such as 100W, 300W, 400W and 600W. Ultrasonic power output had a change of time. We made use of a Thiram hydration and detected it measurement by the ACAO method. It was to decide the result of ultrasonic power supply for time duration and the result of comparison in the 26KHz & 38KHz by UV/VIS spectrophotometer.

  • PDF

Numerical Analysis of Ultrasonic Beam Profile Due to the Change of the Number of Piezoelectric Elements for Phased Array Transducer (Phased Array트랜스듀서에 있어서 구성 압전소자수의 변화에 따른 초음파 빔 전파 특성의 수치 해석)

  • Choi, Sang-Woo;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.207-216
    • /
    • 1999
  • A phased array is a multi-element piezoelectric device whose elements are individually excited by electric pulses at programmed delay time. One of the advantages of using phased array in nondestructive evaluation (NDE) application over conventional ultrasonic transducers is their great maneuverability of ultrasonic beam. There are some parameters such as the number and the size of the piezoelectric elements and the inter-element spacing of the elements to design phased array transducer. In this study, the characteristic of ultrasonic beam for phased array transducer due to the variation of the number of elements has been simulated for ultrasonic SH-wave on the basis of Huygen's principle. Ultrasonic beam directivity and focusing due to the change of time delay of each element were discussed due to the change of the number of piezoelectric elements. It was found that ultrasonic beam was much more spreaded and hence its sound pressure was decreased as steering angle of ultrasonic beam was increased. In addition, the ability of ultrasonic bean focusing decreased gradually with the increase of focal length at the same piezoelectric elements. However, the ability of beam focusing was improved as the number of consisting elements was increased.

  • PDF

A Study on the Characteristics of Ultrasonic Linear Motor Using Piezoelectirc Ceramics (압전세라믹을 이용한 초음파 리니어 모터의 특성연구)

  • Choi, Myeong-Il;Jeong, Dong-Seok;Chong, Hyon-Ho;Lee, Jae-Hyung;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.664-668
    • /
    • 2003
  • Transducer for ultrasonic linear motor with the symmetric and anti-symmetric modes was studied. The ultrasonic linear motor consists of two Langevin type piezoelectric vibrators that cross at right angles with each other in tip. In order to excite symmetric and anti-symmetric modes, the transducer must have a phase shift of 90 degree in space and time. Therefore, the tip of transducer moves on an elliptical motion. In this paper, the finite element analysis was used to optimize dimension and displacement of the transducer. The ultrasonic motor was fabricated using the simulated result and the driving characteristics were measured. No-load velocity was 0.28[m/s] and the maximum efficiency was 30[%] in resonance frequency.

  • PDF

Simulation of Ultrasonic Dry Cleaning for Semiconductor/display Device Application (반도체/디스플레이 소자용 초음파 건식세정 시뮬레이션 연구)

  • Yun, Eui-Jung;Lee, Gang-won;Kim, Chol-Ho;Lee, Seok-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.12
    • /
    • pp.1259-1263
    • /
    • 2004
  • In this paper, the optimum design of ultrasonic dry cleaning head was investigated. The transducer instead of mechanical dynamic structure was used to generate ultrasonic wave and the horn-shape amplifier was utilized to solve the energy decaying problem of ultrasonic wave with propagating it through the media. The analyses of ultrasonic wave and a fluid for the selected structure of a cleaning head were carried out using SYSNOISE and ANSYS simulators, respectively. Based on simulator results, the distance between a horn and the substrate of 4 mm and the horn diameter of 10 mm were determined to maximize the energy of ultrasonic waves. The cooling structure was also considered to reduce the heat from the transducer and the horn. The equivalent circuit for the fabricated horn was deduced from HP4194A impedance/gain/phase analyzer and the frequency of an ultrasonic wave of 20.25 kHz was confirmed using the parameters of the equivalent circuit.