• 제목/요약/키워드: Ultrasonic Transducer

검색결과 606건 처리시간 0.03초

OPMT 초음파 트랜스듀서를 이용한 평판구조 이상진단 (Nondestructive Evaluation of plate structures using the Ultrasonic Transducer OPMT)

  • 김윤영;조승현;이주승;선경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.423-427
    • /
    • 2004
  • In this work, we propose a new ultrasonic damage inspection method in plate structures. The proposed method employs an OPMT (Orientation-adjustable Patch-type Magnetostrictive Transducer) in order to make the ultrasonic waves focused on the specific target point. For experiments, virtual grid points were set up at every 50 mm in an aluminum plate and two OPMTs were used for inspection. If there exists a crack in a plate, the reflected Lamb wave from the crack is measured in addition to the direct waves from the transmitting transducer to the receiving transducer.

  • PDF

멀티주파수 초음파를 사용하는 피부 치료기기 트랜스듀서의 효율적인 주파수 제어 연구 (A Study on Efficient Frequency Control of Transducer for Skin Treatment Using Multi-Frequency Ultrasound)

  • 박종철;김민성
    • 한국멀티미디어학회논문지
    • /
    • 제25권8호
    • /
    • pp.1038-1048
    • /
    • 2022
  • Ultrasound is one of the effective methods for skin treatment. The skin penetration depth of the ultrasound depends on the ultrasonic frequency, that is, when the ultrasonic frequency is high, the depth is shallow. We have developed a transducer which can generate effectively 3 different ultrasonic frequencies removing interference between 3 types of frequencies according to impedance matching technology. The generated powers of transducer are 40.67W at 3.MHz, 17.46W at 11.7 MHz, and 14.79W at 21.5 MHz. The signal interference between the three frequencies is designed so that they do not interfere with each other by separating the signals using the SPDT (Single Pole, Double Throw) switch. The developed hybrid ultrasound transducer can be applied in skin care or skin treatment and beauty therapy.

치과 임플란트 수술용 고출력 초음파 수술기 설계 및 제작 (Design and Fabrication of a High Power Piezoelectric Ultrasonic Surgery Unit for Dental Implantation)

  • 김나리;전대우;김진호;김선욱;황종희;이정배;최성재;임대진;이영진
    • 한국전기전자재료학회논문지
    • /
    • 제30권10호
    • /
    • pp.656-664
    • /
    • 2017
  • This paper presents the design and fabrication of a high power piezoelectric ultrasonic surgery unit for multi-purpose dental implantation. A conventional piezoelectric ultrasonic surgery units consists of a transducer and a tip. However, the drawback of this simple structure is that the output performance of the transducer considerably changes with the change of the tips. An ultrasonic surgery unit that has an additional booster between the transducer and the tip can solve this problem to some extent; for this, an optimal structural design for the transducer is required. We used the Bolted Langevin Transducer (BLT) as the basic transducer; it consists of piezoelectric ceramics and a metal body. It's structure was optimized using mathematical methods to determine the length and radius of the tail and head masses. Additionally, the booster was also subjected to the same methods. Using these mathematical methods, optimal results in terms of the resonance frequency (24.96 kHz), displacement ($14.27{\mu}m$), and pressure (2.8 MPa), could be obtained. The validity of this proposed surgery unit was confirmed experimentally, exhibiting a cutting force of around 7% higher than that of a conventional surgery unit.

자기변형 트랜스듀서의 위상차를 이용한 평판에서의 Lamb파 집속 기초 실험 (Basic Experiment for Lamb Wave Focusing by Phased Magnetostrictive Transducers in a Plate)

  • 이주경;김회웅;이호철;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제21권3호
    • /
    • pp.227-233
    • /
    • 2011
  • The ultrasonic guided wave phased array using magnetostrictive patch transducers is proposed. The magnetostrictive transducer has received much attention because it is cost-effective and capable to generate ultrasonic waves with a simple configuration. However, it has not been used for ultrasonic guided wave phased array applications until now. In this paper, we propose a magnetostrictive transducer based phased array system consisting of a multi-channel function generator, power amplifiers and Lamb wave magnetostrictive transducers. To check the performance of the ultrasonic guided wave phased array, several Lamb wave focusing experiments were carried out in an aluminum plate. The results demonstrated the capability of the developed array to focus the Lamb waves at specific target points.

초음파 변환기의 감도 교정 시스템 구성 (Design of the Calibration System for Determining the Sensitivity of Ultrasonic Transducer)

  • 사공성대;조문재;최봉열
    • 제어로봇시스템학회논문지
    • /
    • 제5권2호
    • /
    • pp.200-207
    • /
    • 1999
  • In this paper, a precise sensitivity measurement system of ultrasonic transducer in the frequency range from 1 MHz to 15 MHz, which can implement the reciprocity principle is constructed. All of the elements of this system such as the ultrasonic preamplifier, ultrasonic absorber, water tank, water degassing system, and four-axes translator and reflector are constructed. For the performance evaluation of the calibration system, a standard hydrophone precisely calibrated from PTB(Physikalisch Technische Bundesanstalt) in Germany are used. And the system parameters which affected the evaluation of the measurement accuracy and the reproducibility in various measuring conditions are considered. The measurement uncertainty of the calibration system is estimated within $\pm$ 2.0㏈.

  • PDF

초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석 (Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer)

  • 남영현
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

주파수 위상 변조에 의한 초음파 탐촉자 변위 발생기에 관한 연구 (A Study on Ultrasonic Transducer displacement generator by Frequency Phase modulation)

  • 김정래
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권3호
    • /
    • pp.36-41
    • /
    • 2002
  • 본 연구에서 개발하고자 하는 기기의 모델은 초음파 탐촉자를 이용하여 변위 조절이 가능한 발생기로써 주파수 위상을 변조하여 26KHz와 38KHz의 초음파 탐촉자의 공진 주파수에서 발생하는 초음파 출력 장치와 초음파 출력량을 100W, 300W, 400W, 600W가 발생하도록 시스템을 설계하였다. 시간의 변화를 주어 초음파 발생의 양을 산출하였고, Thiram 수화제를 사용하여, AOAC method 측정법으로 검출하였으며, UV/VIS spectrophotometer으로 결과치를 판별하였다.

  • PDF

Phased Array트랜스듀서에 있어서 구성 압전소자수의 변화에 따른 초음파 빔 전파 특성의 수치 해석 (Numerical Analysis of Ultrasonic Beam Profile Due to the Change of the Number of Piezoelectric Elements for Phased Array Transducer)

  • 최상우;이준현
    • 비파괴검사학회지
    • /
    • 제19권3호
    • /
    • pp.207-216
    • /
    • 1999
  • 일반적인 하나 또는 두개의 압전소자를 사용하는 트랜스듀서에 비하여 다수의 압전소자를 사용하는 어레이 트랜스듀서는 각 압전소자에 가해지는 펄스의 지연시간을 제어함으로써 초음파 빔을 임의의 지점에 집속시킬 수 있고 기계적 구동없이 임의의 방향으로 조향시켜 실시간 주사를 할 수 있는 장점이 있다. 페이즈드 어레이 트랜스듀서의 설계조건은 압전소자의 수. 압전소자의 크기 그리고 압전소자 사이 간격 등 여러가지가 있으며, 본 연구에서는 그 중에서 압전소자수의 변화에 따른 초음파 빔의 특성을 호이겐스의 원리를 이용한 수평횡파의 시뮬레이션을 통하여 평가하였다. 그 결과 초음파 빔은 조향각이 증가 할수륵 음압이 감소하며, 초음파 빔 특성도 점차적으로 분산됨을 알 수 있었고 또한, 초점거리가 증가할수록 초점에서의 집속효과는 감소하고, 압전소자의 수가 증가되면 집속효과는 향상됨을 알 수 있었다.

  • PDF

압전세라믹을 이용한 초음파 리니어 모터의 특성연구 (A Study on the Characteristics of Ultrasonic Linear Motor Using Piezoelectirc Ceramics)

  • 최명일;정동석;정현호;이재형;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.664-668
    • /
    • 2003
  • Transducer for ultrasonic linear motor with the symmetric and anti-symmetric modes was studied. The ultrasonic linear motor consists of two Langevin type piezoelectric vibrators that cross at right angles with each other in tip. In order to excite symmetric and anti-symmetric modes, the transducer must have a phase shift of 90 degree in space and time. Therefore, the tip of transducer moves on an elliptical motion. In this paper, the finite element analysis was used to optimize dimension and displacement of the transducer. The ultrasonic motor was fabricated using the simulated result and the driving characteristics were measured. No-load velocity was 0.28[m/s] and the maximum efficiency was 30[%] in resonance frequency.

  • PDF

반도체/디스플레이 소자용 초음파 건식세정 시뮬레이션 연구 (Simulation of Ultrasonic Dry Cleaning for Semiconductor/display Device Application)

  • 윤의중;이강원;김철호;이석태
    • 한국전기전자재료학회논문지
    • /
    • 제17권12호
    • /
    • pp.1259-1263
    • /
    • 2004
  • In this paper, the optimum design of ultrasonic dry cleaning head was investigated. The transducer instead of mechanical dynamic structure was used to generate ultrasonic wave and the horn-shape amplifier was utilized to solve the energy decaying problem of ultrasonic wave with propagating it through the media. The analyses of ultrasonic wave and a fluid for the selected structure of a cleaning head were carried out using SYSNOISE and ANSYS simulators, respectively. Based on simulator results, the distance between a horn and the substrate of 4 mm and the horn diameter of 10 mm were determined to maximize the energy of ultrasonic waves. The cooling structure was also considered to reduce the heat from the transducer and the horn. The equivalent circuit for the fabricated horn was deduced from HP4194A impedance/gain/phase analyzer and the frequency of an ultrasonic wave of 20.25 kHz was confirmed using the parameters of the equivalent circuit.