• 제목/요약/키워드: Ultrasonic Scanning

검색결과 284건 처리시간 0.027초

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

All-in-one 접착제에서 초음파진동이 법랑질과 상아질의 결합강도와 레진침투에 미치는 영향 (EFFECT OF ULTRASONIC VIBRATION ON ENAMEL AND DENTIN BOND STRENGTH AND RESIN INFILTRATION IN ALL-IN-ONE ADHESIVE SYSTEMS)

  • 이범의;장기택;이상훈;김종철;한세현
    • 대한소아치과학회지
    • /
    • 제31권1호
    • /
    • pp.66-78
    • /
    • 2004
  • 초기의 접착 시스템은 여러 단계의 술식을 필요로 하였으며 술자의 기술과 재료의 성질에 크게 좌우되었으나 최근 산부식, priming, adhesive를 한번에 적용할 수 있는 all-in-one adhesive system이 등장하였다. 치과에서의 vibration의 이용은 치석의 제거 및 접착제의 점도를 낮추는데 이용되어왔으며 vibration은 접착제의 흐름성을 향상시켜 film thickness를 낮추어 수복물 주위의 미세누출을 줄이는데 도움을 준다. 이에 저자들은 all-in-one adhesive system에서 vibration이 법랑질과 상아질의 접착강도와 레진침투에 미치는 효과를 알아보고자 하였다. 법랑질 시편은 발거 후 실온에서 0.1% thymol 용액에서 보관된 30개의 건전한 사람의 대구치를 무작위로 10개씩 세군으로 나누고 근원심 방향으로 두 부분으로 분리하여 각각은 같은 접착제를 사용하고 초음파진동여부를 다르게 하였고, 아크릴레진을 이용하여 직경 1-inch의 PVC관에 매몰한 후 협설면이 아크릴봉과 동일한 높이가 되도록 220-, 600-grit 연마지로 순차적으로 연마하였고 군당 10개씩 여섯 군으로 분류하였다. 1군과 2군은 Prompt L-Pop(3M-ESPE, Seefeld, Germany), 3군과 4군은 One-Up Bond F(Tokuyama Corp., Tokyo, Japan), 5군과 6군은 AQ bond(Sun Medical Co., Kyoto, Japan)를 제조사의 지시에 따라 도포하였다. 2군, 4군, 6군은 초음파 치석제거기를 이용하여 치면에 대고 15초간 진동을 가한 후 광중합하였다. 상아질 시편은 치관부 법랑질을 제거한 후 상아질면을 아크릴 봉과 동일한 높이가 되도록 하고 법랑질 시편과 동일하게 처리하였다. 이후 직경 2mm, 높이 3mm의 Teflon mold(Ultradent, U.S.A.)를 이용하여 복합레진을 충전한 후 40초씩 두 번에 나누어 광중합한 후 24시간동안 실온에서 증류수에 보관하였다. 열순환 시행한 후, 만능측정기(Instron 4465)로 전단결합강도를 측정하였으며 Resin tag의 양상을 비교하기 위해 각 군의 시편의 치질을 완전히 용해시킨 후 표면을 주사전자현미경사진으로 관찰하여 다음과 같은 결과를 얻었다. 1 법랑질에서 초음파 진동을 가한 군(2, 4, 6군)은 가하지 않은 군(1, 3, 5군)에 비해 평균 전단결합강도가 높게 나타났다. 그 차이는 Ad bond 군을 제외하고 통계적으로 유의하였다(p<0.05). 2. 상아질에서 초음파 진동을 가한 군(2, 4, 6군)은 가하지 않은 군(1, 3, 5군)에 비해 평균 전단결합강도가 높게 나타났다. 그러나 그 차이는 One-Up Bond F군을 제외하고는 통계적으로 유의한 차이가 없었다. 3. 전자 현미경 관찰에서 초음파 진동을 가한 군에서 더 많은 법랑질의 소실과 상아질에서 resin tag의 길이가 길었고 lateral branch의 수도 많이 관찰되었다.

  • PDF

진동이 상아질 결합력에 미치는 영향에 관한 연구 (A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH)

  • 이진;김정욱;이상훈;김종철
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.632-640
    • /
    • 2002
  • 초음파 진동을 치의학에 처음 이용한 것은 치석 제거기였으나, 최근에는 주조금속과 레진 인레이를 접착할 때, 인산아연시멘트나 레진시멘트의 점도를 낮추는데 이용되고 있다. 이러한 초음파 진동은 재료의 흐름성을 증가시킴으로써 피막도를 낮추고, 따라서 수복물 주위의 미제누출을 감소시킬 수 있는 장점이 있다. 그러나, 복합레진의 수복에 있어서 이러한 초음파 진동의 임상적 효과에 관한 연구가 아직까지 미흡한 실정이다. 이에 저자는 초음파 진동을 상아질 결합제에 적용하여 점도를 감소시킴으로써 상아세관으로의 레진 침투 정도의 변화와 결합력에 미치는 효과를 알아보고자 하였다. 발거 후 실온의 0.1% thymol 용액에 보관된 88개의 건전한 사람의 대구치를 치관부 법랑질을 제거하고 아크릴 레진을 이용하여 직경 1-inch의 PVC 관에 매몰하였다. 각 시편의 교합면이 아크릴봉과 동일한 높이가 되도록 220-, 500-grit의 연마지로 순차적으로 연마하였고, 무작위로 추출하여 각 군당 22개씩 네 군으로 분류하였다. 1군과 2군은 Single Bond(3M-ESPE, St. Paul, USA)를 3군과 4군은 One-Step(Bisco Inc., Schaumburg, USA)을 제조사의 지시에 따라 치면을 산부식, 수세, 건조한 후 연속하여 2번을 도포하였다. 2군과 4군은 초음파 치석제거기를 이용하여 치면에 대고 10 초간 진동을 가한 후 광중합하였다. 이후 직경 2.3mm, 높이 3.5mm의 Teflon mold(Ultradent Products Inc., South Jordan, USA)를 이용하여 복합레진을 충전한 후 40초씩 두 번에 나누어 광중합하였다. 모든 시편은 24시간 동안 실온의 수도물에 보관한 후 열순환을 시행하고, 만능측정기(Instron 4465, Canton, USA)로 전단결합강도를 측정하였으며 resin tag의 양상을 비교하기 위해 각 군의 시편의 치질을 탈회시킨 후에 표면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 초음파 진동을 가하지 않은 1군, 3군에 비해 초음파 진동을 가한 2군과 4군에서 전단결합강도가 유의하게 높게 나타났다(p<0.05). 2. Single Bond와 One-Step의 전단결합강도는 유의한 차이를 보이지 않았다(p>0.05). 3. 전자현미경 관찰에서 초음파 진동을 가한 군에서 resin tag의 길이가 길었고, lateral branch의 수도 많이 관찰되었다.

  • PDF

임플란트 표면에 따른 인공치면세균막 형성에 관한 연구 (THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES)

  • 김진우;한세진;김경욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

고주파수 초음파 검출장에서 SiC 세라믹 내부의 미세결함 검출 (Detection of Small Flaws in SiC Structural Ceramic in High Frequency Detection Field)

  • 김병극;이승석
    • 비파괴검사학회지
    • /
    • 제17권2호
    • /
    • pp.100-107
    • /
    • 1997
  • 파괴역학적 고려에 의하여 구조용 세라믹에서 $100{\mu}m$보다 작은 크기의 결함을 검출하는 것이 요구되고 있다. 미세결함이 삽입된 세라믹 시편을 준비하여 고주파수 검출장에서 C-scan을 수행하였다. 두께 4m의 SiC 세라믹 시편들을 입도가 $100{\mu}m$에서 $200{\mu}m$ 범위의 Fe, 입도 $36{\mu}m$에서 $50{\mu}m$ 범위의 Fe와 $50{\mu}m$ 크기의 pore를 용침법(infiltration)으로 삽입하여 준비하였고 또 입도 $100{\mu}m$에서 $200{\mu}m$ 범위의 WC, 입도 $36{\mu}m$에서 $50{\mu}m$ 범위의 WC, 입도 $100{\mu}m$에서 $200{\mu}m$ 범위의 Si, 입도 $36{\mu}m$에서 $50{\mu}m$ 범위의 Si 입자들을 소결법(sintering)으로 삽입하여 준비하였다. 준비된 시편에 대해 중심주파수 80MHz의 polyvinylidene fluoride(PVDF) 초음파탐촉자를 사용하여 C-scan을 수행한 결과 100MHz 범위까지의 고주파수 성분을 지닌 검출장에서는 $36{\mu}m$에서 $200{\mu}m$ 범위의 미세결함들이 검출되었으나 60MHz 이하의 주파수 성분만으로 구성된 저주파수 검출장에서는 검출되지 않았다. 중심 주파수에서의 파장에 대하여 검출된 최소 결함의 비는 약 0.25로 Rayleigh 산란 영역이었다.

  • PDF

우레탄 폼 코아 샌드위치 구조물의 정적 및 피로 특성 (Static and Fatigue Characteristics of Urethane Foam Cored Sandwich Structures)

  • 김재훈;이영신;박병준;김덕회;김영기
    • Composites Research
    • /
    • 제12권6호
    • /
    • pp.74-82
    • /
    • 1999
  • 폴리 우레탄 폼 코아 샌드위치 복합재료의 정적 및 피로 특성에 대하여 연구하였다. 유리 섬유강화 스킨과 중합의 폼 코아를 갖는 비스티칭, 스티칭, 스티프너의 세 종류 시편이 사용되었다. 특히 스티칭 샌드위치 구조는 두께 방향에 대하여 폴리에스터와 유리섬유를 꼬아서 부가적인 구조 보강이 코아의 상하 표면을 통하여 꿰멘 구조로 층간분리를 최소화하기 위해 샌드위치 구조 패널을 스티칭하여 만들고 수지는 수지의 유동 온도에서 수지의 낮은 점도 특성을 이용하여 스티칭 섬유에 침투시켜 함께 경화하였다. 스티칭 섬유가 $50{\times}50{\;}mm$의 간격으로 스티칭된 시편 및 스티프너 시편의 굽힘강도는 비스티칭 시편과 비교하여 각각 50%및 10배 이상으로 향상되었다. 최대 하중의 20%크기로 $10^6$ 피로 사이클을 받은 후, 비스티칭 시편의 굽힘 피로강도는 정적 굽힘강도와 비교하여 27%까지 감소되었고, 스티칭된 시편은 39%,그리고 스티프너에 의하여 보강된 시편은 20%정도 감소되었다. 폴리우레탄 폼 코아의 에이징 효과를 입증하기 위해, 피로 시험 후 샌드위치 시편의 표면 적층의 손상은 초음파 C-scan장비를 사용하여 검출하였다. 초음파 C-scan결과로부터 피로 시험동안 손상 받은 어떤 결함도 없었다 이는 피로 사이클동안 폼 코아 샌드위치 구조에 대한 굽힘강도의 감소는 폴리우레탄 폼이 에이징되어 발생하는 것을 의미한다.

  • PDF

영역카메라를 이용한 이송중인 제재목의 화상처리시스템 개발 (The Development of Image Processing System Using Area Camera for Feeding Lumber)

  • 김병남;이형우;김광모
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권1호
    • /
    • pp.37-47
    • /
    • 2009
  • 최근 목재산업계에서는 사람의 시각을 대체하는 기계시각을 이용한 화상처리시스템을 도입하여 제재목 등급 판정의 자동화, 제품의 품질향상 및 재단 최적화 등에 활용하고 있다. 본 연구에서는 국내산 소나무 제재목을 대상으로 표면결함검출을 위한 화상처리시스템을 개발하고자 하였으며, 주로 이용되고 있는 라인스캔카메라를 대신하여 비교적 저가의 영역카메라를 이용하였을 때 발생되는 문제점을 해결하고자 하였다. 벨트컨베이어의 불균일한 이송속도에 따른 문제점을 해결하기 위해 화상의 특징점을 이용한 결과 효과적인 화상병합을 할 수 있었다. 일반적인 영역카메라는 송재속도 15.7 m/min 이상에서는 모션블러에 의한 화상의 품질저하로 인하여 화상처리가 어려웠고 화상처리에 적합한 송재속도는 13.8 m/min였으며 추후 송재속도를 향상시키기 위해서는 전자셔터 속도가 빠른 카메라의 사용이 요구되었다. 녹색 컨베이어벨트상의 제재목 화상의 배경과의 분리를 위해서는 RGB필터의 red 채널을 이용하면 효과적이었다. 옹이검출을 위한 문턱값 판정법은 화상분석형인 문턱값 감소법이 우수하였으며 히스토그램분석형 중에서는 엔트로피법이 적합하였다.

교합면 소와 열구에서 산부식 제재의 효과적인 침투 방법에 대한 연구 (A STUDY ON THE EFFECTIVE PENETRATION OF ETCHING AGENT IN OCCLUSAL PIT & FISSURE)

  • 이성룡;이상호;이창섭;이난영
    • 대한소아치과학회지
    • /
    • 제32권3호
    • /
    • pp.472-480
    • /
    • 2005
  • 치면열구전색술의 우식예방효과는 전색제의 유지력과 밀접한 연관이 있으며, 이는 전 단계 과정인 산부식제의 열구 내 침투율에 따라 달라질 수 있다. 본 연구에서는 교합면 소와 및 열구에 산부식제의 효과적인 침투를 위해 여러 가지 방법을 적용하여 비교 분석하였다. 이를 위해 발거된 상악 제 1, 2 소구치 40개를 각각 10개씩 4개의 군으로 나누었다. I군은 교합면 소와 및 열구 부위에 통법에 따라 산부식제를 도포하였고 II군은 각 치아의 교합면 소와 및 열구부위에 산부식제 도포와 함께 초음파 진동을 주었다. III군은 각 치아의 교합면 소와 및 열구부위에 열구성형술(Fissurotomy)를 시행한 후 산부식제를 도포하였고, IV군은 각 치아의 교합면 소와 및 열구부위에 열구성형술후 산부식제 도포와 초음파 진동을 동시에 시행하였다. 이상의 실험 후 각 군의 산부식제 침투도를 비교 연구하여 다음과 같은 결과를 얻었다. 1. 각 군의 산부식제 침투도를 비교한 결과, 각각 III군과 IV군에서 I군에 대해 향상된 침투도를 관찰할 수 있었다(P<0.05). 2. 부위별 군에 따른 침투도를 비교한 결과, 근심 소와부위와 원심 소와부위에서는 III군과 IV군이 I군에 대해 향상된 침투도를 보였으나(P<0.05), 열구 중앙부위는 각 군 간에 차이가 없었다(P>0.05).

  • PDF

체외수정란 이식시 수태율에 미치는 요인에 관한 연구 (Factors affecting pregnancy rates following transfer of bovine embryos derived from in vitro fertilization of oocytes matured in vitro)

  • 김성기;노상호;이은송;이병천;황우석
    • 대한수의학회지
    • /
    • 제36권4호
    • /
    • pp.919-927
    • /
    • 1996
  • In the last few years, methods for in vitro culture of early embryo stages from oocytes matured and fertilized in vitro using suitable cell culture systems have been established. But the factors affecting pregnancy rates following transfer of bovine embryos produced in vitro were not evaluated enough. So this study was performed to investigate the effects of quality and stage of embryos, parity and Corpus Luteum quality of recipients on pregnancy rates following non-surgical transfer of bovine embryos produced in vitro. Oocytes aspirated from small antral follicles of ovaries obtained at a local slaughter house were matured, fertilized with frozen-thawed semen and co-cultured for 6-7 days by utilizing co-culture system with bovine oviduct epithelial cell in vitro. After co-culture, embryos were transfered to recipients on day 7 (estrus=day 0). Recipients were monitored by ultrasonic scanning method or observation for estrus and rectal palpation after 50 days from transfer. The results of this study are follows. 1. Of the 70 recipients, 70%(49 of 70) had not showed estrus sign between day 0 and day 50, but 22.9%(16 of 70) was diagnosed not pregnant. Therefore the overall pregnancy rate of this study was 47.1%(33 of 70). 2. The pregnancy rate of recipients transfered with excellent(66.7%) and good(54.5%) embryos were higher than that of recipients transfered with fair embryos(15.8%) (p<0.05). 3. The pregnancy rate of recipients transfered with morula, compacted morula, blastocyst and expanded blastocysts were 46.2, 55.0, 62.5 and 50.0%, respectively. 4. The pregnancy rates of recipients transfered to heifer and cow were 54.5 and 55.2%, respectively. 5. The pregnancy rates of recipients with CL score I, II(66.7, 63.6%) were higher than those of recipients with CL score III (10%), (p<0.05). Success of transfer of embryos produced in vitro depends on many variables. The important factors identified in this study were the quality of embryos and the CL score of recipient animals after non-surgical transfer of embryos matured, fertilized and cultured in vitro.

  • PDF

Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구 (A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics)

  • 정용수;이진한;이재인;동진근
    • 구강회복응용과학지
    • /
    • 제24권3호
    • /
    • pp.231-242
    • /
    • 2008
  • 본 연구의 목적은 전부 도재관 시스템에서 코어-비니어 결합계면에서의 결합 강도를 평가하는데 있다. 본 연구에서 사용되어진 전부 도재관 시스템은 IPS Empress2 with IPS Eris, IPS e.max Press with IPS e.max Ceram과 IPS e.max ZirCAD with IPS e.max Ceram이다. 제조사의 지시에 따라 코어(N=36, N=12/system, 직경: 10mm, 두께: 3mm)를 제작하였고 초음파 세척을 시행하였다. 특별히 제작된 스테인리스 스틸 몰드를 이용하여 코어 상부에 비니어(직경: 3mm, 두께: 2mm)를 축성한 후 소성하였다. 소성 후, 초음파 세척을 시행하고 아크릴릭 레진에 매몰하였다. 제작된 시편은 $37^{\circ}C$의 증류수에 1주일간 보관하였다. 만능시험기(Z020, Zwick, Germany)로 시편의 전단결합강도를 측정하였고, 하중이 코어-비니어 계면에 가능한 가깝게 가해지도록 시편을 위치시키고, 파절이 일어날 때까지 1.00mm/min의 crosshead speed로 하중을 가하였다. 측정된 각 군의 평균전단결합강도($MPa{\pm}SD$)에 대한 통계적 유의성을 검증하기 위해 일원 분산분석을 시행하였으며, 사후검정은 Tukey test를 이용하였다(p=0.05). 또한 파절된 시편을 주사전자현미경(JSM-6360,JEOL, Japan)으로 파절양상을 관찰하였다. 파절양상은 코어 내에서의 응집성 파절, 비니어 내에서의 응집성 파절, 혼합형 파절 혹은 접착성 파절로 분류하였다. 코어와 비니어 계면에서의 평균전단결합강도($MPa{\pm}SD$)는 IPS-e.max Press가 $32.85{\pm}6.75MPa$, IPS Empress 2가 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD가 $28.10{\pm}4.28MPa$로 나타났다. 통계적 분석 결과 각 시스템 간에서 유의한 차이가 없었다(P>0.05). 어떠한 시스템에서도 접착성 파절은 관찰되지 않았다. IPS Empress 2와 IPS e.max Press에서는 코어와 비니어 내에서의 응집성 파절이 관찰되었으며, IPS e.max ZirCAD에서는 혼합형 파절과 비니어 내에서의 응집성 파절이 관찰되었다.