• Title/Summary/Keyword: Ultrasonic Meter

Search Result 69, Processing Time 0.025 seconds

Evaluation of Ultrasonic Multiple Scattering Method to Improve the Accuracy of Fine Dust Measurement (비산먼지 측정 정확도 개선을 위한 시뮬레이션 초음파 다중 산란 알고리즘 검증)

  • Woo, Ukyong;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.119-128
    • /
    • 2020
  • An ultrasonic multiple scattering simulation using cross-section of fine dust particles were proposed. These days, along with awareness of air pollution, social interest in fine dust is increasing. In the construction field, awareness of fine dust is increasing, and research on preparing various countermeasures is underway. The light scattering method fine dust meter currently in use is affected by environmental factors such as relative humidity, and reliability problems in terms of accuracy are continuously reported. However, the transmission of ultrasonic waves can directly reflect the physical change of the medium based on the mechanical wave. Using these advantages of ultrasonic waves, fine dust measurement simulation was performed using the scattering cross section and ultrasonic multiple scattering theory. The shape data of the fine dust particles were collected using a SEM (Scanning Electron Microscope), and a cross-section according to the fine dust particles was derived through numerical analysis. As a result of signal processing, the error for the number density corresponding to each cross-section is minimum 19, maximum 3455.

Application of the Velocity Index Method for Discharge Computation in Tidal River Basin (감조하천의 유량산정을 위한 유속지수법의 적용)

  • Song, Jae-Hyun;Lee, Suk-Ho;Kim, Chi-Young;Lee, Jin-Won;Jung, Sung-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1342-1345
    • /
    • 2009
  • 조위영향을 받는 감조하천에서는 조위변화의 주기적인 특성으로 인해 일반적인 수위와 유량의 관계가 성립하기 어렵기 때문에 최근 ADVM(Acoustic Doppler Velocity Meter) 또는 UVM (Ultrasonic Velocity Meter)과 같은 자동 유량측정 기법을 통한 연속유량측정이 이루어지고 있다. 한강대교 수위관측소는 대표적인 감조구간으로 이러한 문제를 해결하기 위해 ADVM 방식의 자동유량측정시설이 설치되어 운영 중에 있으며, H-ADCP 센서를 통해 측정된 유속을 Chiou의 무차원단면유속분포법을 이용하여 유량을 계산한다. 이는 최대유속을 유량산정의 지표로 하여 유량을 계산하는 방법으로, 본 연구에서는 한강대교 자동유량측정시설의 측정성과를 이용하여 유속지수법과 무차원유속분포법에 의해 산정된 유량을 비교하였고, 앞의 방법들을 검증하기 위하여 2008년 ADVM을 이용한 이동보트법으로 측정된 유량과 비교하였다.

  • PDF

Improvement to the Methods of Discharge Computation for the Automated Real-time Discharge Measurement System (자동유량측정시설의 유량산정방법 개선)

  • Song, Jae-Hyun;Kim, Dae-Young;Jin, Suk-Hwan;Roh, Young-Sin;Kim, Chi-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.472-477
    • /
    • 2010
  • 자동유량측정시설은 연속적인 유량자료를 측정하기 위해 운영되는 실시간-무인화 유량측정 시스템이다. 현재 국내 외에서 유량측정을 위해 설치 및 운영되고 있는 자동유량측정시설은 대부분 초음파유속계를 이용하고 있는는데, 초음파유속계는 유속을 측정하는 방식에 따라 크게 도플러방식 초음파유속계(ADVM, Acoustic Doppler Velocity Meter)와 이동시간차방식 초음파유속계(UVM, Ultrasonic Velocity Meter)로 분류된다. 본 연구에서는 각 방식별로 유량산정방법을 개선하기 위해 설치 운영 중인 자동유량측정시설 중 고령교 지점의 ADVM 방식과 여주, 적성 지점의 UVM 방식을 대상으로 측정성과에 대한 문제점을 분석하고 통계적인 방법을 통해 오측유속을 제거하거나 방식별 또는 지점별 특성을 고려하여 적절한 유량산정방법을 적용하였다. 그 결과 3개 지점에 대한 검증유량과의 평균 상대오차율은 모두 10% 이내로 나타났다.

  • PDF

Mathematical Model Expression of Portable Calibration System for Float Type Water Level Meters (부자식 수위계를 위한 이동형 교정시스템의 수학 모델)

  • Hong, Sung-taek;Shin, Gang-wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1964-1972
    • /
    • 2017
  • K-water have been operating as an International accredited calibration organization for ISO 17025 regarding float, ultrasonic and radar type since 2008. Due to the absence of on-site calibration system, water level meter could only be calibrated from a laboratory. Therefore K-water institute developed an mobile calibration system for water-level meter in 2015 to calibrate the water-level meter on site. The mobile calibration system was certificated by KOLAS(Korea Laboratory Accreditation Scheme) in 2016. In this paper a mobile calibration system, which is a method to calibrate float type water level meter on site, is established. A mathematical equation was derived by reviewing characteristics of standard equipment and measurement. By developing the mobile calibration system, it is possible to achieve reliability of data through scientific system operation on hydrological data.

Performance Analysis of the Lubricating Oil Feed Pump by the Anslysis of the Flow Network (유로망 해석에 의한 윤활유 공급펌프 성능 해석)

  • Kil, Doo-Song;Lee, Young-Ho
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.62-67
    • /
    • 2002
  • In this paper, the cause of the discrepancy of the inlet and outlet flow of the lubricating oil feed pump was analyzed by the flow measurement and the analysis of the flow network. At first, we thought that the flow difference was induced by a leak in the middle of the flow network. But, through the flow measurement using ultrasonic flow meter and the performance analysis of the pump, we knew that the cause of the flow difference was due to a drop in efficiency of the pump according to the pressure drop of the outlet. Also, we knew that the shape of the piping had no effect on the efficiency of the pump.

  • PDF

Design of Micro-meter Position Driver for X-Y Stage Using Linear Ultrasonic Motor (리니어 초음파 모터를 이용한 X-Y stage의 마이크로 미터급 위치 구동회로 설계)

  • Kim, Jeong-Do;Hong, Chul-Ho;Kim, Dong-Jin;Ham, Yu-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.165-171
    • /
    • 2005
  • The ultrasonic piezo motor is a new type motor that has an excellent performance and many useful features that electromagnetic motors do not have. But, it suffers from severe system non-linearities and parameter variations especially during speed control. Therefore, it is difficult to accomplish satisfactory control performance by using the conventional PID controller. In this paper, to achieve the precise control for linear type ultrasonic motor was analyzed as a function of response time and change with a driving time. Also, we propose controller that combines STEP controller and PD controller that have error of ${\mu}m$ about liner type ultrasonic motor.

  • PDF

A Study on the Development of a method for estimating the amount of gate opening discharge in estuary using the three-dimensional fixed measurement of flow data for Integrated Nakdong-river estuary management (낙동강하굿둑 통합관리를 위한 3차원 고정식 유량 측정 자료를 이용한 하굿둑 개도 방류량 산정 기법 개발)

  • Kang, Dukee;Seo, Yongjae;Lim, Kyoungmo;Park, Byeong Woo
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.52-58
    • /
    • 2022
  • Recently, various efforts and research are being conducted to integrated management of the estuary in Nakdong River. As one of such studies, measurement of opening discharge amount for each floodgate using a three-dimensional fixed ultrasonic flow meter is being conducted, but studies on hydraulic and statistical processing procedures and techniques using actual measurement results for calculating discharge amount by opening remain at the basic level. Therefore, in this study, a data processing technique using three-dimensional fixed ultrasonic flow meter measurement data was developed, the flow coefficient was calculated based on the measured data, and the applicability of the discharge amount calculation formula development was reviewed.

Construction of Ultrasound Pulsed Doppler Velocimeter (펄스 초음파 도플러 속도계의 제작에 관한 연구)

  • 현석봉;김수용;이재수
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1994
  • To measure the velocity of heart wall and local flow transctaneously in blood vessels, we have developed a single channel 3.1 MHz pulsed ultrasonic Doppler velocity meter. Ultrasound pluse width and repetition frequency (PRF) used in the velocity meter is 1 ${\mu}$sec 6kHz reapectively, and the Doppler shift of the backscattered echo signal is sensed in a phase detector by coherent demodulation method. From the output of the phase detector, the Doppler signal corresponding to the mean velocity of acoustic wave scatterers over a small region is obtained by using a range gate, sample holder and band-pass filter. Mean frequency of Doppler signal is estimated by zero-crossing counter and the instantaneous velocity of scatters is displayed as a function of time. It is possible to estimate velocity profile, volume flow and flow acceleration of vessels in man if the number of channels and range resolution in increased.

  • PDF

Application of Filtering Method to Improve the Quality of Automatically Measured Discharge Data (자동유량측정 자료의 개선을 위한 필터링 방법의 적용)

  • Chang, Kwon-Hee;Kim, Chi-Young;Kim, Soo-Jun;Song, Jae-Hyun;Kim, Hung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1405-1409
    • /
    • 2010
  • 최근 우리나라는 물 부족 국가로서 물의 효율적 관리 필요성 증대, 기후변화에 따른 가뭄 홍수 피해 증가 등으로 신뢰성 있는 수문자료구축이 필요성이 요구되고 있다. 그 중 유량측정 분야는 모든 수자원 계획과 관리의 근간이 되는 분야로 그 중요성 또한 간과 할 수 없는 부분이다. 현재 우리나라에서는 한국건설기술연구원 산하 유량조사사업단에 의해 유량측정 주요지점에 자동유량측정 시설을 설치하고 이를 운영함으로써 각 지점의 특성에 따라 적절한 방식을 채택하여 이동시간차방식 초음파 유속계(UVM, Ultrasonic Velocity Meter)와 도플러방식 초음파유속계(ADVM, Acoustic Doppler Velocity Meter)를 설치하면서 향후 수문계측 분야 선진화를 위한 기초자료를 제공하고 있다. 하지만 실시간 무인화 계측시스템에 의해 제공되는 자료가 양질의 자료임을 보장할 수 없는 현실이기 때문에 측정된 기초자료의 필터링을 통한 자료의 질적 개선이 필요하다. 따라서 본 연구에서는 기존에 전산분야의 필터링 방법으로 널리 알려져 있는 LPF(Lowpass Filter)와 KF(Kalman Filter)를 이용하여 자동유량측정 자료의 필터링 방법으로 활용하고, 그 적용성을 검토하였다. 본 연구를 통해 기존 유량자료의 문제점을 개선하고 효율적인 유량조사를 위한 기초자료 확보 방법으로 활용될 수 있을 것으로 기대된다.

  • PDF

Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter (UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.