• 제목/요약/키워드: Ultrasonic Experiment

검색결과 430건 처리시간 0.03초

초음파검사용 젤 용기의 제균을 위한 세척방법 평가 (Evaluation of Washing Method for Sterilization of Gel Container for Ultrasound Inspection)

  • 이희정;이석준;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.241-247
    • /
    • 2018
  • The purpose of this study was to compare the ultrasound gel container washing methods for the sterilization of contaminants and to find the useful methods for the prevention of infection caused by the ultrasonic gel containers. In this experiment, a 250 mL ultrasonic gel container was used, and the ultrasonic gel used was a non-sterile gel (ECO GEL 99, SeungWon Medical, Korea). In order to evaluate the degree of contamination, new 250 mL 15 containers were divided into 5 groups to perform five types of washing by no treatment, washing with water, washing with soap, washing with bottle cleaner and high disinfection level washing. After the washing process, filled the gel container with gel and after 2 weeks, the number of colonies in the gel container was sampled repeatedly twice in the same ultrasonic laboratory and compared before and after washing. As a result of among the five cleaning methods used in this study, 87.2% and 88.9% of the soapy water washing (p = 0.028) and high level washing (p = 0.027) showed significant bacterial reduction rates, respectively. Our findings conclusively an ultrasonic gel container cleaning method for removing contaminants has been found to be an effective sterilization method at a low cost with a soapy water cleaning method. Therefore, it is expected that it will be helpful to prevent the infection caused by the ultrasonic gel container by suggesting the sterilization cleaning method that is practically useful in this study.

초음파 치료의 효율성 향상을 위한 초음파 온열 시뮬레이터 개발 (The Development of Ultrasonic Hyperthermia Simulator to Improve the Efficiency of Ultrasonic Therapy)

  • 유우진;노시철;정동환;박재현;최민주;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권5호
    • /
    • pp.418-427
    • /
    • 2009
  • As many people are westernizing their life style and food consumption habits, a number of patients who have malignant tumors which grow very rapidly and hazardously destroy the human body are increasing. Ultrasonic hyperthermia is not only one of the tumor treatment methods which employs the non-radioactive ultrasonic waves to increase the temperature at the tumor region up to $40\sim45^{\circ}C$ to destroy and suppress tumor cells but also has been proved by many studies. Due to the rapid development of High Intensity Focused Ultrasound(HIFU), the ultrasound hyperthemia extensively boosts its applications in clinical field. For those reasons, Computed simulation factor should be needed before inspection to patients. To prove efficiency of ultrasonic hyperthermia, precise acoustic field measurement considering tissue characteristics and a heating experiment with tissue mimicking material phantom were conducted for effectiveness of simulation program. Finally, in this study, the computer simulation program verified the anticipated temperature effects induced by ultrasound hyperthermia. In the near future, it is hoped that this simulation program could be utilized to improve the efficiency of ultrasound hyperthermia.

Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로 (Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality)

  • 박익근
    • 비파괴검사학회지
    • /
    • 제14권2호
    • /
    • pp.112-121
    • /
    • 1994
  • 초음파 C-scan 기법에 의해 스폿(spot)용접의 품질 평가를 위한 비파괴진단 평가에 관한 기초적인 실험적 검토를 하였다. 먼저, 스폿용접부 초음파탐상에 앞서 뉴우톤링의 모델링 실험을 통해 미소 간극을 갖는 접합계면에서의 초음파 반사 거동의 해석 결과를 근거로 스폿용접부의 너겟 형상과 크기, void 결함등의 정량적 평가와 corona bond의 정확한 식별에 최적한 초음파시험방법 및 조건의 설정을 시도하였다. 초음파시험 후 용접시험편을 절단하고, 그 절단면을 초음파현미경(SAM)과 광학현미경의 단면 관찰을 통해 스폿용접 품질 평가를 위한 초음파 비파괴평가법의 유용 가능성 유무, 적용 한계 등을 검토하였다. 그 결과 본 실험에 사용한 집속 초음파탐촉자(25MHz)에 의한 너겟 내부에 존재하는 void 크기의 검출한계는 $10{\mu}m$였으며 너겟 크기는 초음파시험의 경우가 최대 1mm정도 크게 측정되어 corona bond의 정확한 식별과 너겟 직경의 정량적 평가에 접근하기 위해서는 초음파 C-scan 데이터의 각종 화상 처리 기술의 적용에 의한 corona bond부의 명확한 식별 방법에 대한 연구 검토가 요망됨을 알 수 있었다.

  • PDF

A Study on Cost-effective Treatment of Wastewater and Odor Reduction for Southeast Asian Market Entry

  • Jung, Min-Jae;Kim, Yong-Do;Kwon, Lee-Seung;Lee, Woo-Sic;Kwon, Woo-Taeg
    • 산경연구논집
    • /
    • 제9권12호
    • /
    • pp.23-29
    • /
    • 2018
  • Purpose - The purpose of this study is to apply a cost effective ultrasonic odor reduction method that generated micro-bubbles using ejector to the Southeast Asian wastewater market. Research design, data, and methodology - A leather maker located in Ansan-city, Gyunggi-do, South Korea was sampled from the collection tank to select experimental materials. Experimental setup consisted of circulating water tank-air ejector-ultrasonic device, and circulating wastewater. Sample analysis was performed by CODcr, T-N, T-P, and turbidity by the National Environmental Science Institute. Results - Experimental results show that it is most effective in removing odors when the frequency range of ultrasonic wave is 60~80 Khz and the output is 200 W. It showed that the concentration of complex odor dropped from a maximum of 14,422 times to a minimum of 120 times. Also, analysis of ammonia and hydrogen sulfide in specific odor substances has shown that they were reduced from 1.5 ppm to 0.4 ppm and from 0.6 ppm to 0.1 ppm, respectively. Conclusions - It is possible to shorten more than 12 hours in the treatment of micro-organisms. It can be seen that the processing time of odor after ultrasonic treatment in the pre-treatment facility is reduced by 25% when compared to the resultant micro-organisms after the chemical treatment, that is, the time of the bio-treatment of micro-organisms. Based on the results, it was confirmed that the pre-treatment method using the ultrasonic and the air ejector device of the experiment shows the effect of reducing the water pollutants and odor more effectively in a relatively short time than the conventional advanced oxidation method.

초음파 처리 조건에 따른 집락형 유해남조류 Microcystis 세포수 변화 연구 (Colonial Cyanobacteria, Microcystis Cell Density Variations using Ultrasonic Treatment)

  • 이혜진;박혜경;허준;이현제;홍동균
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.210-215
    • /
    • 2018
  • It is difficult to count colonial cyanobacteria Microcystis cells since the thickness of colonies is constrained by amorphous mucilage, making it impossible to estimate the number of cells. Disaggregation of Microcystis colonies into single cell is needed to improve the accuracy and precision of cell density estimation of naturally collected samples. Uultrasonic treatment method is commonly used owing to the simplicity and immediacy of the procedure. However, amplitude, frequency, and duration of ultrasonic treatment also cause cell loss during the experiment. Optimal ultrasonic treatment has not been standardized yet. Therefore, the objective of this study was to investigate optimal ultrasonic treatment by analyzing cell density and colony numbers. We collected colonial Microcystis from Changnyeong-Haman weir area in Nakdong River during harmful algal boom period from September to October in 2017. Ultrasonic treatment method was applied to disrupt colonies into single cells to enumerate cell density. Among treatment conditions, results from continuously treated for 100 seconds were found to be the optimum to reduce colonies to a suspension of single cell without cell losses under high and low density of Microcystis cells. Lugol iodine fixed cells followed by sonication showed less negative impact of cell damage within the optimal treatment time (100 seconds). Furthermore, disaggregated cells treated by sonication enables microscopic observation more easily since gas vacuoles were collapsed to facilitate sedimentation of cells under the counting chamber for quantitative enumeration of buoyant Microcystis cells.

초음파 수침법을 이용한 터빈베어링 Babbitt금속 박리 검사 기술 (Implementation of Ultrasonic Immersion Technique for Babbitt Metal Debonding in Turbine Bearing)

  • 정계조;박상기;조용상;박병철;길두송
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.348-353
    • /
    • 2004
  • 이 연구는 터빈베어링의 신뢰성을 평가하기 위하여 초음파 C-Scan 방법을 적용한 기술이다. 수침법에 관한 연구는 실험실과 현장검사 적용에 광범위하게 사용되는 기술이다. 여기에서는 C-Scan 방법을 이용하여 베어링의 모재와 Babbitt 금속간 경계부의 상태를 평가하였다. 수침법 C-Scan 방법에 의한 초음파 영상은 베어링 경계부의 상태를 확인하는데 효과적인 방법으로 사용될 수 있었다. 초음파 영상의 분해능을 높이기 위하여 집속형 탐촉자를 사용하고, Babbitt 금속과 베어링 모재간의 접합경계면에서 발생하는 초음파 음압 반사율을 측정하여 결함의 검출과 면적을 추정할 수 있었다. 초음파 수침법은 베어링 접합부의 박리위치와 박리면적의 경계면을 결정하여 크기를 계산하는데 아주 유용하게 사용될 수 있는 기술이며, 이 연구에서 개발된 기술은 화력발전소에서 사용되고 있는 터빈베어링의 건전성을 확보하는데 적용되었다.

초음파 도플러를 이용한 음성 인식 (Automatic speech recognition using acoustic doppler signal)

  • 이기승
    • 한국음향학회지
    • /
    • 제35권1호
    • /
    • pp.74-82
    • /
    • 2016
  • 본 논문에서는 음성 신호 대신 초음파 도플러 신호를 이용하여 음성을 인식하는 새로운 음성 인식 방법을 제안하였다. 제안된 방법은 주변 잡음에 대한 강인성과 무 접촉식 센서 사용에 따른 사용자의 불편함 감소를 포함하는 기존의 음성/무음성 인식 방법에 비해 몇 가지 장점을 갖는다. 제안된 방법에서는 40 kHz의 주파수를 갖는 초음파 신호를 입 주변에 방사하여, 반사된 신호를 취득하고, 취득된 신호의 도플러 주파수 변화를 이용하여 음성 인식을 구현하였다. 단일 채널 초음파 신호를 사용하는 기존의 연구와 달리, 다양한 위치에서의 취득된 초음파 신호를 음성 인식에 사용하기 위해 다채널 취득 장치를 고안하였다. PCA(Principal Component Analysis)특징 변수를 사용한 음성 인식에는 좌-우 모델을 갖는 은닉 마코프 모델을 사용하였다. 제안된 방법의 검증을 위해 60개의 한국어 고립어에 대해 6명의 화자로부터 취득된 초음파 도플러 신호를 인식에 사용하였으며, 기존 음성기반 음성인식 기법과 비교할 만한 수준의 인식율을 얻을 수 있었다. 또한 실험 결과 제안된 방법은 기존의 단일 채널 음성 인식 방법과 비교하여 우수한 성능을 나타내었으며, 특히 잡음 환경에서도 90 % 이상의 인식율을 얻을 수 있었다.

고체내부에 존재하는 결함의 형태에 따른 초음파 신호의 특징 추출 (Feature Extraction of Ultrasonic Signal due to Form of Defect in Solids)

  • 문상택
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1993년도 학술논문발표회 논문집 제12권 1호
    • /
    • pp.169-173
    • /
    • 1993
  • In this paper, the features extraction of reflected signals from various type of defects existing in the solid has been studied by Wiener filtering technique. In this experiment, three types of the defect have been considered; a flat cut, a angular cut and a circular hole. All of the defects have the same size, 20mm in diameter and have been located at 45mm in depth from the aluminum surface. In the result of the experiment, it has been found that the wiener filtering technique used for features extraction from the reflected signal corresponding to each defect have been very effective for defect classification.

  • PDF

로봇 구조에 따른 이동거리 오차 보정 알고리즘 개발 (A Movement Distance Error Correction Algorithm Development According to the Structure of the Robot)

  • 임신택;정길도
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1097-1098
    • /
    • 2008
  • In this paper We are going experiment which can happen at the movement of the robot to reduce the Systematic distance error. The system get the experiment result by using BLDC Motor, Encoder, ultrasonic sensor. The Embedded XP is adopted as an operating system, And The robot was controlled by using RS232.

  • PDF

초음파 진동자에 의해 유도된 음향유동을 이용한 첨단 냉각법 (A Novel Cooling Method by Acoustic Streaming Induced by Ultrasonic Resonator)

  • 노병국;이동렬
    • 한국음향학회지
    • /
    • 제22권3호
    • /
    • pp.217-223
    • /
    • 2003
  • 30 ㎑의 초음파 (ultrasonic wave)의 미세 진동에 의해서 유도된 음향유동 (acoustic streaming)에 의한 공기대류를 이용한 새로운 냉각방법을 소개한다. 초음파 진동은 압전소자 (piezoelectric device)에 의해서 얻어지며 50 m 정도의 진동진폭을 얻기 위해 기계적 진동 증폭자인 혼 (horn)을 추가하여 전체 진동 시스템이 공진하도록 구성된다. 음향유동에 의한 열전달 효과의 상승을 측정하기 위해 열원 (heat source) 및 열원 주위의 대기의 온도변화를 실시간으로 측정하였다. 초음파 진동 시작 후 시간지연 없이 음향유동이 유도되어 진동자 주위의 대량의 공기유동으로 인한 급격한 온도감소가 관찰되었다. 또한 열원과 진동자와의 거리가 방사 (radiation)되는 음파 (sound wave)의 반파장 (half wave length)의 정배수가 될 때 열원의 냉각효과가 극대화됨을 실험적으로 관찰하였다. 이는 음파의 공진현상에 기인한 것으로 이론적 고찰을 통한 검증 또한 수행되었다. 음향유동을 이용한 냉각법의 장점은 초음파 진동을 이용하기 때문에 무소음이며 이동 형태의 부품이 없기 때문에 반영구적으로 사용할 수 있다. 또한 기존의 전기모터를 이용한 냉각팬 (cooling fan)으로는 냉각이 어려운 초소형 기전시스템 (MEMS)의 냉각법으로 사용될 수 있는 첨단 냉각방법이다.