• 제목/요약/키워드: Ultrasonic Excitation

검색결과 81건 처리시간 0.024초

A Method to Simulate Frictional Heating at Defects in Ultrasonic Infrared Thermography

  • Choi, Wonjae;Choi, Manyong;Park, Jeonghak
    • 비파괴검사학회지
    • /
    • 제35권6호
    • /
    • pp.407-413
    • /
    • 2015
  • Ultrasonic infrared thermography is an active thermography methods. In this method, mechanical energy is introduced to a structure, it is converted into heat energy at the defects, and an infrared camera detects the heat for inspection. The heat generation mechanisms are dependent on many factors such as structure characteristics, defect type, excitation method and contact condition, which make it difficult to predict heat distribution in ultrasonic infrared thermography. In this paper, a method to simulate frictional heating, known to be one of the main heat generation mechanisms at the closed defects in metal structures, is proposed for ultrasonic infrared thermography. This method uses linear vibration analysis results without considering the contact boundary condition at the defect so that it is intuitive and simple to implement. Its advantages and disadvantages are also discussed. The simulation results show good agreement with the modal analysis and experiment result.

Rail Inspection Using Noncontact Laser Ultrasonics

  • Kim, Nak-Hyeon;Sohn, Hoon;Han, Soon-Woo
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.696-702
    • /
    • 2012
  • In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd-Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real-time rail inspection from a high-speed train are discussed.

배열형 Fiber-PZT 센서 시스템의 개발 (Development of Fiber-PZT array sensor system)

  • 임승현;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.212-213
    • /
    • 2008
  • Ultrasonic fiber sensor is more cost-effective than optical fiber sensor using light. However, optical fiber lines are separately used for sensing. Thus, if it is applied for huge system, it is need many lines of the sensor systems. To overcome this point, novel ultrasonic sensor systems considering wave cancellation and modulation were newly developed. By using this schema, reference-free sensor system can be developed. By using ultrasonic waves of different excitation frequencies, multiple input-signal output sensor system was also developed by applying spectrum analyses. Using the array type sensor system, the leakage of liquid and its evaporation can be monitored successfully.

  • PDF

레이저 진동 측정기를 이용한 초음파 이송 시스템의 동작특성에 관한 연구 (A Study on the Motion Characteristics of the Ultrasonic Transport System using Laser Scanning Vibrometer)

  • 정상화;신병수;이경형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.155-158
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

Laser Scanning Vibrometer를 이용한 초음파 이송시스템의 이송 메커니즘에 관한 연구 (A Study on Transport Mechanism of the Ultrasonic Transporting System using Laser Scanning Vibrometer)

  • 정상화;신병수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.841-844
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

Time Reversal Beam Focusing of Ultrasonic Array Transducer on a Defect in a Two Layer Medium

  • Jeong, Hyun-Jo;Lee, Jeong-Sik;Bae, Sung-Min
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.242-247
    • /
    • 2009
  • The ability of time reversal techniques to focus ultrasonic beams on the source location is important in many aspects of ultrasonic nondestructive evaluation. In this paper, we investigate the time reversal beam focusing of ultrasonic array sensors on a defect in layered media. Numerical modeling is performed using the commercially available software which employs a time domain finite difference method. Two different time reversal approaches are considered - the through transmission and the pulse-echo. Linear array sensors composed of N elements of line sources are used for signal reception/excitation, time reversal, and reemission in time reversal processes associated with the scattering source of a side-drilled hole located in the second layer of two layer structure. The simulation results demonstrate the time reversal focusing even with multiple reflections from the interface of layered structure. We examine the focusing resolution that is related to the propagation distance, the size of array sensor and the wavelength.

정상 초음파장의 간섭에 의한 메탄/공기 예혼합화염의 구조 변이 (Structural Variation of Methane/Air Premixed Flame Caused by the Intervention of Ultrasonic Standing-wave)

  • 서항석;이상신;김정수
    • 한국추진공학회지
    • /
    • 제15권6호
    • /
    • pp.1-6
    • /
    • 2011
  • 본 연구에서는 정상초음파장의 간섭에 의해 야기되는 예혼합화염의 구조 변이를 규명하기 위한 실험 결과를 제시한다. 화염전파를 관찰하기 위해 슐리렌 기법을 이용하였으며, 초기압력 및 연소챔버 개방 유무에 따른 화염선단의 형태 및 화염 전파속도를 고찰하였다. 정상초음파장에 의한 화염선단의 찌그러짐이 관찰되었고, 초음파장의 특성이 변하지 않는 한 그 수직방향으로의 위치는 일정하였다. 정상초음파의 영향을 받은 화염은 전파할수록 구조적 변화가 심해졌으며, 전파속도 또한 증가하였다. 반사파와 정상초음파의 영향으로 연꽃모양의 화염(lotus flame)이 형성되는 사실을 발견할 수 있었다.

온도 보상을 이용한 자기변형 위치 센서의 정확도 향상 방법 (A Novel Method for Improving the Positioning Accuracy of a Magnetostrictive Position Sensor Using Temperature Compensation)

  • 유은주;박영우;노명규
    • 센서학회지
    • /
    • 제28권6호
    • /
    • pp.414-419
    • /
    • 2019
  • An ultrasonic based magnetostrictive position sensor (MPS) provides an indication of real target position. It determines the real target position by multiplying the propagation speed of ultrasonic wave and the time-of-flight between the receiving signals; one is the initial signal by an excitation current and the other is the reflection signal by the ultrasonic wave. The propagation speed of the ultrasonic wave depends on the temperature of the waveguide. Hence, the change of the propagation speed in various environments is a critical factor in terms of the positioning accuracy in the MPS. This means that the influence of the changes in the waveguide temperature needs to be compensated. In this paper, we presents a novel way to improve the positioning accuracy of MPSs using temperature compensation for waveguide. The proposed method used the inherent measurement blind area for the structure of the MPS, which can simultaneously measure the position of the moving target and the temperature of the waveguide without any additional devices. The average positional error was approximately -23.9 mm and -1.9 mm before and after compensation, respectively. It was confirmed that the positioning accuracy was improved by approximately 93%.

메탄/공기 예혼합화염의 동역학적 거동에 대한 정상초음파의 교반 효과 (Agitation Effects of an Ultrasonic Standing Wave on the Dynamic Behavior of Methane/Air Premixed Flame)

  • 서항석;이상신;김정수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.318-323
    • /
    • 2012
  • 본 연구에서는 정상초음파와 교반하는 메탄/공기 예혼합화염의 동역학적 거동을 규명하기 위한 실험결과를 제시한다. 슐리렌 기법을 이용하여 전파하는 화염을 가시화하였고, 이미지 후처리를 통해 정상초음파 유무에 따른 화염선단의 형상 및 전파속도를 관찰하였다. 전파속도는 연소한계를 제외한 당량비에서 정상초음파장이 가진되는 경우에 더욱 증가하였으며, 화염선단의 찌그러지는 위치는 초음파 특성이 변하지 않는 한 일정하였다.

  • PDF