• Title/Summary/Keyword: Ultrasonic

Search Result 5,820, Processing Time 0.026 seconds

Development and Application of an Ultrasonic Gas Flowmeter (초음파 가스 유량계 개발과 활용)

  • Hwang, Won-Ho;Park, Sang-Gug;Jeong, Hee-Don;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.246-253
    • /
    • 2002
  • This paper describes the development and the field application of the ultrasonic gas flowmeter for accurate measurement of the volumetric flow rate of gases in a harsh environmental conditions in iron & steel making company. This ultrasonic flowmeter is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. This is a transit time type ultrasonic flowmeter. We have developed the transmitting & receiving algorithm of ultrasonic wave and the ultrasonic signal processing algorithm to develope a transit time type ultrasonic flowmeter. We have evaluated the performance of ultrasonic flowmeter by the calibration system with Venturi type standard flowmeter. We has confirmed its reliability by extensive field tests for a year in POSCO, iron & steel making company. Now we have developed the commercial model of ultrasonic flowmeter and applied to the POSCO gas line.

Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer (광대역 초음파 변환기를 위한 전기 임피던스 정합 연구)

  • Kim, Geonwoo;Kim, Ki-Bok;Baek, Kwang Sae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.37-43
    • /
    • 2017
  • Ultrasonic transducers with high resolution and resonant frequency are required to detect small defects (less than hundreds of ${\mu}m$) by ultrasonic testing. The resonance frequency and resolution of an ultrasonic transducer are closely related to the thickness of piezo-electric materials, backing materials, and the electric impedance matching technique. Among these factors, electrical impedance matching plays an important role because it can reduce the loss and reflection of ultrasonic energy differences in electrical impedance between an ultrasonic transducer and an ultrasonic defects detecting system. An LC matching circuit is the most frequently used electric matching method. It is necessary for the electrical impedance of an ultrasonic transducer to correspond to approximately $50{\Omega}$ to compensate the difference in electrical impedance between both connections. In this study, a 15 MHz immersion ultrasonic transducer was fabricated and an LC electrical impedance circuit was applied to that for having broad-band frequency characteristic.

Effects of Ultrasonic Treatment Time on the Quality and Palatability of fried Chicken Meat (초음파 처리시간이 튀김 계육의 품질 및 기호성에 미치는 영향)

  • 남주현;송형익;박충균;박성하;김도완;문윤희;정인철
    • Food Science of Animal Resources
    • /
    • v.22 no.2
    • /
    • pp.115-121
    • /
    • 2002
  • This study was carried out to investigate the effect of ultrasonic treatmeat time on the quality and palatability of fried chicken meat. Moisture content, U-10 treatment (chicken meat treated by ultrasonification for 10 minutes) of breast and leg were lower than those of the control, protein contents were not different between samples. Fat content was higher with increasing ultrasonic treated time. Frying loss of ultrasonic treated breast and leg were lower than those of the control, water holding capacity of ultrasonic treated breast and leg were higher than those of the control with increasing ultrasonic treated time. Rheological textures between control and ultrasonic treated samples were not different. L* value(lightness) between control and ultrasonic treated samples were not different, but L* values of breast were higher than those of the leg. And a* value(redness) was not effect by ultrasonic treatment, but a* value of leg were higher than those of the breast. Amino acid composition has included many glutamic acid, aspartic acid, lysine, leucine and arginine. Oleic acid and linoleic acid occupied beyond 50% of fatty acid composition. And taste, texture, juiciness and palatability improved with increasing ultrasonic treated time.

Characteristics of Ultrasonic Signals Caused by Corona Discharge in Air (코로나방전에 의한 공중(空中)초음파 신호 특성)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.38-46
    • /
    • 1999
  • Measurerments of ultrasonic signals caused by corona discharges were perforrred by using an ultrasonic meeasurerment technique to analyze the deve1qxrent states of coronas in a high-voltage power apparatus. We also examined the relationship between discharge magnitude and ultrasonic pulse number to diagnose the deterioration of electrical insulation by corona discharges. From these results, it was found that ultrasonic signals due to corona discharges can be firstly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of ultrasonic signals was closely related to the current pulses by the corona discharges when ac voltages were gradually raised, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, tirre-delaying and directivity charocteristics of ultrasonic signals propagated to air by using ultrasonic oscillation and receiving systems are feJXlrt.ed as a basic data of ultrasonic measurements in out-door HV apparatus.aratus.

  • PDF

A Study on the Detection Algorithm of an Advanced Ultrasonic Signal for Hydro-acoustic Releaser

  • Kim, Young-Jin;Huh, Kyung-Moo;Cho, Young-June
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.767-775
    • /
    • 2008
  • Methods used for exploring marine resources and spaces include positioning a probe under water and then recalling it after a specified time. Hydro-acoustic Releasers are commonly used for positioning and retrieving of such exploration equipment. The most important factor in this kind of system is the reliability for recalling the instruments. The frequently used ultrasonic signal detection method can detect ultrasonic signals using a fixed comparator, but because of increased rates of errors due to outside interferences, information is repetitively acquired. This study presents an effective ultrasonic signal detection algorithm using the characteristics of a resonance and adaptive comparator Combined with the FSK+ASK modulator. As a result, approximately 8.8% of ultrasonic wave communication errors caused by background noise and transmission losses were reduced for effectively detecting ultrasonic waves. Furthermore, the resonance circuit's quality factor was enhanced (Q = 120 to 160). As such, the bias voltage of the transistor (Vb= 3.3 to 6.8V) was increased thereby enhancing the frequency's selectivity.

Generic Procedure Development for the Ultrasonic Examination of Dissimilar Metal Welds in Nuclear Power Plants (원전 이종금속 용접부 초음파 검사 일반 절차서 개발)

  • Yang, Seung Han;Kim, Yong Sik;Yoon, Byung Sik;Guon, Kee Il
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • To enhance the reliability of ultrasonic testing system, MOST(Ministry of Science and Technology) bulletin 2004-13 was published in 2004.6 requiring performance demonstration in ultrasonic examination and MEST(Ministry of Education, Science and Technology) 2009-37 was published in 2009.9(formerly MOST bulletin 2004-13). In order to meet the MEST bulletin requirement and increase the reliability of ultrasonic testing, all the ultrasonic examination procedure and equipment should be performance demonstrated and qualified. In this paper, generic procedure for the ultrasonic examination of dissimilar metal welds are described and new technique are introduced.

  • PDF

A Study on the Ultrasonic Effect for Turbulence Enhancement in the Flow Field of a Coaxial Circular Pipe (동심원관 유동장에서 난류증진을 위한 초음파 영향에 관한 연구)

  • Song, Min-Geun;Koo, Ja-Hoon;Lee, Sang-Bum;Son, Seung-Woo;Ju, Eun-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.742-747
    • /
    • 2001
  • A study on the ultrasonic effect for turbulence enhancement is carried out in the horizontal flow field of a coaxial circular pipe. A large transparent acryl tank is made to perform several experiments for the above research. The front flow field from jet exit is divided as 4 measuring regions to observe characteristics of the above flow field according to those with and without ultrasonic. An ultrasonic transducer with 2MHz high frequency is used to give them the ultrasonic forcing. Characteristics such as the velocity distribution, the kinetic energy and the turbulence intensity are visualized, observed, examined and considered at Re No. 2000. In results, it is clarified that the ultrasonic increases the turbulence enhancement. And the optimum and harmonious intensity suited to the power of flow is needed to maximize the turbulence enhancement.

  • PDF

Effect of Ultrasonic Treatment on Colorants Extraction and Dyeability of Safflower (초음파처리가 홍화의 색소추출과 염색성에 미치는 영향)

  • Kim, Yong-Sook;Choi, Jong-Myoung
    • Journal of the Korean Home Economics Association
    • /
    • v.45 no.10
    • /
    • pp.13-20
    • /
    • 2007
  • A new method for competent extraction of safflower (Carthamus tinctorius Linnaeus) colorants by using ultrasonic device was developed. When comparing to general extraction method, the ultrasonic method showed high extraction efficiency of safflower pigments. Ultrasonic method gave a higher extraction yield of red and yellow safflower pigments than using general method. It is supposed that the extraction efficiency is to be attributed to high vibration energies from ultrasound and finally induced physical changes of the pigments. Furthermore, this study explored the effects of ultrasonic treatment into the extracted safflower pigments on dyeing of cotton fabrics. Ultrasonic treatment into the extracted pigments exhibited significantly improved dyeing properties for the cotton fabrics.

A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants (원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구)

  • Yu Sung-Sik;Park Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

Design of Ultrasonic Tool Horn for Wire Wedge Bonding (와이어 본딩용 초음파 공구혼 설계에 관한 연구)

  • Lee, Bong-Gu;Oh, Myung-Seok;Ma, Jeong-Beom
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.717-722
    • /
    • 2013
  • In this study, we investigated the design of a wire wedge bonding ultrasonic tool horn using finite element method (FEM) simulations. The proposed method is based on an initial design estimate obtained by FEM analysis. An ultrasonic excitation causes various vibrations of a transducer horn and capillary. A simulated ultrasonic transducer horn and resonator are then built and characterized experimentally using a laser interferometer and electrical impedance analyzer. The vibration characteristics and resonance frequencies close to the exciting frequency are identified using ANSYS. FEM analysis is developed to predict the resonance frequency of the ultrasonic horn and use it in the optimal design of an ultrasonic horn mode shape.