• Title/Summary/Keyword: Ultra-high performance liquid chromatography system

Search Result 11, Processing Time 0.023 seconds

UHPLC System Shutdown and Reactivation Advice (UHPLC 시스템 종료 및 재가동 시 가이드)

  • Mark Fever;Gemma Lo
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.8.1-8.3
    • /
    • 2024
  • Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.

  • PDF

Column cleaning, regeneration and storage of silica-based columns (실리카 기반 컬럼의 세척, 재생 및 보관 가이드)

  • Matt James;Mark Fever
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.1.1-1.4
    • /
    • 2024
  • This article provides comprehensive guidance on the maintenance, cleaning, regeneration, and storage of silica-based HPLC (High-Performance Liquid Chromatography) columns. The general considerations emphasize the importance of using in-line filters and guard cartridges to protect columns from blockage and irreversible sample adsorption. While these measures help, contamination by strongly adsorbed sample components can still occur over time, leading to an increase in back pressure, loss of efficiency, and other issues. To maximize column lifetime, especially with UHPLC (Ultra-High Performance Liquid Chromatography) columns, it is advisable to use ultra-pure solvents, freshly prepared aqueous mobile phases, and to filter all samples, standards, and mobile phases. Additionally, an in-line filter system and sample clean-up on dirty samples are recommended. However, in cases of irreversible compound adsorption or column voiding, regeneration may not be possible. The document also provides specific recommendations for column cleaning procedures, including the flushing procedures for various types of columns such as reversed phase, unbonded silica, bonded normal phase, anion exchange, cation exchange, and size exclusion columns for proteins. The flushing procedures involve using specific solvents in a series to clean and regenerate the columns. It is emphasized that the flow rate during flushing should not exceed the specified limit for the particular column, and the last solvent used should be compatible with the mobile phase. Furthermore, the article outlines the storage conditions for silica based HPLC columns, highlighting the impact of storage conditions on the column's lifetime. It is recommended to flush all buffers, salts, and ion-pairing reagents from the column before storage. The storage solvent should ideally match the one used in the initial column test chromatogram provided by the manufacturer, and column end plugs should be fitted to prevent solvent evaporation and drying out of the packing bed.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

An HPLC method for the determination of thioctic acid in raw material and tablets

  • Mai, Xuan-Lan;Ahn, GyeChan;Lee, SeokHan;Kang, Jong-Seong;Woo, Mi Hee;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.221-225
    • /
    • 2017
  • Thioctic acid is a vitamin-like antioxidant which is prepared as tablets and injection. The Korean Pharmacopoeia (KP XI) contains monograph for the quality control of raw thioctic acid using ultra-violet visible spectrophotometry and its formulations using high performance liquid chromatography (HPLC). In British Pharmacopoeia 2013 (BP2013), another HPLC method is used for the assay test of thioctic acid material. For the international harmonization, we present an HPLC method for quantitation of thioctic acid in both raw material and tablets. Method validation was performed to determine linearity, precision, accuracy, system suitability, and robustness. The linearity of calibration curves in the desired concentration range was high ($r^2=0.9995$), while the RSDs for intra- and inter-day precision were 0.93 ~ 1.26 % and 1.40 ~ 1.76 %, respectively. Accuracies ranged from 98.13-100.00 %. Since the system suitability, intermediate-precision and robustness of the assay were satisfactory, this method will be a valuable addition to the Korean Pharmacopoeia (KP XI).

Comparison of 2-D RP-RP MS/MS with 1-D RP MS/MS for Proteomic Analysis (단백체 분석을 위한 일차원 및 이차원 역상크로마토그래피의 비교)

  • Moon, Pyong-Gon;Cho, Young-Eun;Baek, Moon-Chang
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.377-386
    • /
    • 2010
  • Single-dimensional (1-D) and two-dimensional (2-D) LC methods were utilized to separate peptides from various sources followed by MS/MS analysis. Two-dimensional ultra-high performance liquid chromatography is a useful tool for proteome analysis, providing a greater peak capacity than 1-D LC. The most popular 2-D LC approach used today for proteomic research combines strong cation exchange and reversed-phase LC. We have evaluated an alternative mode for 2-D LC of peptides using 2-D RP-RP nano UPLC Q-TOF Mass Spectrometry, employing reversed-phase columns in both separation dimensions. As control experiments, we identified 129 proteins in 1-D LC and 322 proteins in 2-D LC from E. coli extract peptides. Furthermore, we applied this method to rat primary hepatocyte and a total of 170 proteins were identified from 1-D LC, and 527 proteins were identified from all 2-D LC system. The in-depth protein profiling established by this 2-D LC MS/MS from rat primary hepatocyte could be a very useful reference for future applications in regards to drug induced liver toxicity.

Quantification of Arsenic Species in Some Seafood by HPLC-AFS (HPLC-AFS를 이용한 해산물 중 비소 화학종 분리정량)

  • Jeong, Seung-Woo;Lee, Chae-Hyeok;Lee, Jong-Wha;Jang, Bong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.496-503
    • /
    • 2021
  • Background: Considering the expenses of and difficulties in arsenic speciation by high performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS), alternative measurement methods should be useful, especially for large-scale research and projects. Objectives: A measurement method was developed for arsenic speciation using HPLC-atomic fluorescence spectrometry (HPLC-AFS) as an alternative to HPLC-ICP-MS. Methods: Total arsenic and toxic arsenic species in some seafoods were determined by atomic absorption spectrometry coupled with hydride vapor generation (AAS-HVG) and HPLC-AFS, respectively. Recovery rate of arsenic species in seafood was evaluated by ultra sonication, microwave and enzyme (pepsin) for the optimal extraction method. Results: Limits of detection of HPLC-AFS for As3+, dimethylarsinate (DMA), monomethylarsonate (MMA) and As5+ were 0.39, 0.53, 0.60 and 0.64 ㎍/L, respectively. The average accuracy ranged from 97.5 to 108.7%, and the coefficient of variation was in the range of 1.2~16.7%. As3+, DMA, MMA and As5+ were detected in kelp, the sum of toxic arsenic in kelp was 40.4 mg/kg. As3+, DMA, MMA and As5+ were not detected in shrimp and squid, but total arsenic (iAS and oAS) content in shrimp and squid analyzed by AAS-HVG were 18.1 and 24.7 mg/kg, respectively. Conclusions: HPLC-AFS was recommendable for the quantitative analysis method of arsenic species. As toxic arsenic species are detected in seaweeds, further researches are needed for the contribution degree of seafood in arsenic exposure.

Effect of Plant Growth Regulator Treatment on Isoflavones in Soybean

  • Jinhee Seo;Seoyeon Hong;Hyerang Park;Jaesung Park;Okjae Won;Eunji Seo;Wonyoung Han;Kido Park
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.164-164
    • /
    • 2022
  • The soybean (Glycine max(L.) Merrill), an important food crop in the world, is popular because of its high quality protein and oil content. Soybeans as a food have long been known for their beneficial effects on health and are well-recognized globally. Isoflavones, significant soybean secondary metabolic products, may be crucial in avoiding some cancers and lowering the risk of cardiovascular disorders. This study investigates the correlation between plant growth regulator and the effect on the isoflavone levels in soybean leaves. The study was carried out in the green-house of the southern crop department in miryang. Soybeans(Seonpung) were cultivated in 1/2000 of the Wagner pot. Ethephon(500, 1000, 2000 ppm) and ABA(100, 200, 400 ppm) were used as plant growth regulators, and they were each treated on R2, R5, and R7 stage. After treatment, leaves were sampled three times at intervals of 5 days, and the content of 6 isoflavones and coumestrol was analyzed. Soybean isoflavones were analyzed using Ultra Performance Liquid Chromatography (Acquity UPLC H-Class system, Waters). The isoflavones content showed an overall highly in the R5 stage, and the level was similar to that of no treatment in the R2 and R7 stage. The difference between the growth regulators was found to be higher than that of ethephon when ABA was treated. The coumestrol content was confirmed to be high in the order of R7, R5, and R2 on the treatment time, and it was found that the content increased as the treatment time was delayed. In the treatment with the growth regulator, the coumestrol content tended to be higher when ethephon was treated than ABA.

  • PDF

Cultivation, UHPLC Pattern Analysis, and Inhibitory Effect on Respiratory Inflammation of Lysimachia mauritiana Lam. (갯까치수염(Lysimachia mauritiana Lam.)의 재배 및 UHPLC 패턴 분석, 호흡기염증 억제 효과)

  • Dong-Seon Kim;Heung Joo Yuk;JungMi Kim;Chaeseok Koh;Younjung Jang;Yoon-Young Sung
    • The Korea Journal of Herbology
    • /
    • v.39 no.3
    • /
    • pp.77-84
    • /
    • 2024
  • Objectives : Lysimachia mauritiana Lam. is known as a medicinal plant native to Korea that has antioxidant, anticancer, antibacterial, and antiviral activities. However, until now, research on the cultivation technology of L. mauritiana is insufficient, and there are no research data on the systematic cultivation method and mass production of L. mauritiana. Therefore, this study aims to establish a cultivation system of L. mauritiana. Methods : The cultivation environment of open land and facilities according to the growth of L. mauritiana was compared and tested. In addition, the equivalence of the origin collection extract and the cultivation extract was evaluated through Ultra high performance liquid chromatography (UHPLC) patterns analysis according to cultivation and comparison of the effect of inhibiting respiratory inflammation using BEAS-2B human bronchial epithelial cells. Results : The cultivation technology system was established through cultivation research of L. mauritiana raw materials. In addition, as a result of comparing and evaluating the equivalence of cultivated plants and L. mauritiana raw materials for suppressing respiratory inflammation, the same results were confirmed, and the equivalence was confirmed as a result of analyzing the UHPLC pattern with L. mauritiana raw materials. Conclusions : This study suggests that extract from cultivation research of L. mauritiana plants, which are native to Korea, can be used as a health functional food or medicine to improve respiratory health.

Secondary Metabolites and Morphological Diversity in the Leaves of Perilla Landrace from Korea

  • Assefa, Awraris Derbie;Sung, Jung-Sook;Jeong, Yi-Jin;Lee, Ho-Sun;Rhee, Ju-Hee;Hur, On-Sook;Noh, Jae-Jong;Ro, Na-Young;Hwang, Ae-Jin;Lee, Jae-Eun
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.64-64
    • /
    • 2019
  • Screening and identification of genetic resources based on their phytoconstituents and morphological characters potentially provide baseline data for researchers, breeders, and nutraceutical companies who wish to formulate a nutrient-dense diet and health beneficial supplement. Thus, we evaluated the amount of total phenolic content and major phenolic compounds; examined if phenolic compounds could be used as distinguishing factors for perilla genetic resources; and investigated the relation between some quantitative and qualitative morphological characters with the contents of phenolic compounds in 360 accessions obtained from National Agrobiodiversity Center gene bank, Jeonju, Korea. Total phenolic content (TPC) was estimated using Folin-Ciocalteu colorimetric assay. Individual phenolic compounds were determined using an Ultra-High Performance Liquid Chromatography system equipped with Photodiode Array detector. Considerable variations were observed in TPC (7.99 to 117.47 mg GAE/g DE), rosmarinic acid (RA) (ND to 19.19 mg/g DE), caffeic acid (CA) (ND to 0.72 mg/g DE), apigenin-7-O-diglucuronide (ADG) (ND to 1.24 mg luteolin equivalent (LUE)/g DE), scutellarein-7-O-glucuronide (SG) (ND to 4.32 mg LUE/g DE), and apigenin-7-O-glucuronide (AG) (ND to 1.60 mg LUE/g DE). RA was the most dominant phenolic compound in most accessions (95.3%) followed by SG. The adaxial leaf color was light green, green and dark green in 13.8%, 65.0%, and 21.1 % of the accessions, respectively. 78.8% of the accessions had light green color at the abaxial side with the remaining being described as green. Most of the accessions (96.9%) were cordate shape, the remaining being eclipse. Intensities of green pigment at abaxial and adaxial leaf surfaces were correlated with contents of individual phenolic compounds and TPC whereas leaf length and width had no correlation with TPC, CA and RA, and negatively correlated with ADG, AG, and SG. Leaf shape was not related with content of phenolic compounds, color of leaves, or the length or width of leaves. Accessions IT57426, IT157434, IT267710, and IT267712 which contained relatively high contents of TPC and major phenolic compounds (RA and SG) could be used for further research in breeding and bioassay test. Our study result showed the contents of total phenolics and individual phenolic compounds along with the morphological characters could be useful distinguishing factors for perilla genetic resources.

  • PDF

Measurement of the Anti-oxidative Properties of Extract from Medicinal Plants Using an On-line HPLC-DPPH Assay (HPLC와 DPPH radical 소거능 측정 방법의 결합에 의한 약용 식물 추출물의 항산화 활성 비교)

  • Im, Do-Youn;Pyo, Byoung-Sik;Kim, Sun-Min;Lee, Kyoung-In
    • Journal of Life Science
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Natural anti-oxidative compounds have important disease prevention and food preservation properties, in addition to anti-bacterial, anti-inflammation, anti-cancer, and skin whitening effects. High-performance liquid chromatography (HPLC), with an ultra vilolet (UV) detector coupled to a reverse phase C18 column and an online measurement system for 1, 1-diphenyl-2-picryl hydrazyl (DPPH) radicals, was used to search for potent antioxidative compounds in crude extracts. The online HPLC-DPPH assay was then applied to confirm antioxidative compounds in water extracts from Radix of Pueraria lobata, Rhizoma of Zingiber officinale, Fructus of Chaenomeles sinensis, Cortex of Ulmus pumila, and Radix of Astragalus membranaceus. To determine the yields of the extracts, the Brix% of each extract solution was measured using a refractometer. When the relative DPPH radical scavenging ability values of the water extracts were compared with those of a positive control (ascorbic acid), the water extracts of P. lobata, C. sinensis, and U. pumila were 7.77%, 4.71%, and 4.19%, respectively. The results suggest that this method provides a useful assay for rapid measurement of DPPH radical scavenging abilities and conformation of antioxidative compounds in natural products. Moreover, it can reduce the time spent on the separation of active compounds from natural materials, such as medicinal plants, in addition to the use of reagents for separation.