• Title/Summary/Keyword: Ultra sound

Search Result 92, Processing Time 0.022 seconds

Thermal stabilityof fluorine doped silicon oxide films

  • Lee, Seog-Heong;Yoo, Jae-Yoon;Park, Jong-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 1998
  • The reliability of fluorine doped silicon oxide (SiOF) films for intermetal dielectrics in multilevel interconnections of ultra-large scale integrated circuits (ULSIs) is investigated. SiOF films were deposited by electron cyclotron resonance plasma-enhanced chemical vapor deposition (ECRPECVD) using H-free source gases, i.e., SiF4 and O2. The effect of post plasma treatment on the moisture absorption and dielectric properties of SiOF films was carried out I terms of air exposure time, The reliability test of Cu/TiN/SiOF/Fi specimen was carried out in terms of temperature by rapid thermal annealing (RTA) in N2 ambient. After O2 plasma treatment,, no appreciable peak directly related to moisture absorption was detected. The capacitance-voltage (C-V) characteristics of the O2 plasma treated SiOF film showed that the film remained to hold the sound dielectric properties even after boiling treatment. The Cu/TiN/SiOF/Si system was found to be reliable up to $600^{\circ}C$.

A Study on the Development of Classifier for Recycling of Abrasive (연마제 재활용을 위한 분급장치 개발에 관한 연구)

  • Kim, Moon Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.20-24
    • /
    • 2017
  • For process improvement and cutting down on expenses in solar cell industry, it is necessary to improve recycling process of wafer manufacturing. In this research, a study is introduced to develop classifier which is for recycling of abrasive. First of all, recycling process of wafer manufacturing is analyzed. And then, 3 steps of experiments such as oil removal, impurities removal and classification were executed. For the classification of slurry, a classifier is designed and manufactured. From experiments, it is verified that ultra sound vibration and flux are very important factors for classification. By experiencing the recycling processes and making devices, the technique can be initiated industry if needed such as decreasing waste and cutting down on expenses.

  • PDF

Audio Signal Format and Coding Method for Ultra High Definition Television (UHDTV) (초고선명 방송을 위한 오디오 포맷 및 부호화 기법)

  • Seo, Jeong-Il;Kang, Kyeong-Ok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.580-588
    • /
    • 2009
  • In this paper, we describe technical trends, standard activities, and upcoming issues relating on UHDTV audio, which requires high quality realistic sound. We also propose a proper solution to it for domestic broadcasting and telecommunication environments.

Friction and Wear Behavior of Ultra-Thin TiN Film during Sliding Wear against Alumina and Hardened Steel (마모 상대재 변화에 따른 TiN 극박막의 마찰 및 마모거동)

  • Song, Myeong-Hun;Lee, Jae-Gap;Kim, Yong-Seok
    • Korean Journal of Materials Research
    • /
    • v.10 no.1
    • /
    • pp.62-68
    • /
    • 2000
  • Ultra thin TiN films (50∼700nm thickness) were deposited on AISI 304 stainless steel substrates using a reactive DC magnetron sputtering deposition process to investigate their wear and friction properties. Dry sliding wear tests of the films were carried out against hardened steel and alumina counterparts using a pin-on-disk type wear tester at room temperature. Variation of friction coefficient was measured as a function of film thickness, load, sliding speed and roughness of the substrate. Worn surfaces of the film were examined by a scanning electron microscope. Wear resistance of the TiN film increased with the increase of the film thickness. The TiN film showed relatively high wear resistance in spite of its ultra thin thickness when it is mated by the steel counterpart, while it showed poor wear resistance with the alumina counterpart. The good wear resistance with the steel counterpart was explained by the formation of oxide layers on the film surface and sound interface character between the ultra thin film and the substrate.

  • PDF

The Effects of ESWT and US on Muscle Power, Pain and Muscle Tension at Trigger Point of the Scapular Inter Angle (견갑골 내측 상부의 발통점에 체외충격파와 초음파 적용시 통증과 피부두께, 근력변화에 미치는 영향)

  • Lee, Seung-Hyub;Pi, Eo-Ra;Jung, Ha-Ney;Lee, Ho-Seok;Joo, Da-Sol;Lee, Seung-Hee;Choi, Min-Hee;Choi, Hyun-Ji;Hong, Young-In;Kim, Ji-Eun;Han, Sang-Wan
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • Purpose : This study aims to investigate into the change in muscle power, pain and muscle tension upon application of extracorporeal shock wave therapy (ESWT) and ultrasound (US) at trigger point (TrP) of the Scapular inter angle. Methods : In total of 24 human subjects that experience pain upon stimulation at the scapular inter angle were recruited. They were divided into three groups: control, ESWT and US group. Each group was subjected to appropriate stimulation three times per week for four weeks except the control group which had no restrictions in lifestyle. The ESWT group was subjected to Extracorporeal Shock Wave Therapy with a 2 $cm^2$ head, 20 times at speed of application of 60 pulses/min and depth of intrusion of 25 mm Whereas the US group was subject to Ultra sound therapy with 1$cm^2$ head, 1 MHz in frequency, 1.5 W/$cm^2$ of strength with five minutes of continuous application. Measurements were performed immediately prior to and at the end of the experiment. Results : There was no statistical significance in the change in muscle tension and muscle power as well as the difference between both groups before and after the experiment. VAS and VRS, all of which indicates changes in pain level, had statistically significant differences between them in pretest posttest comparisons. However, ESWT was superior to US in terms of decreasing muscle tension and pain while increasing muscle power. Conclusion : This study has made it evident that ESWT is far more reasonable to apply to TrP.

Non-uniform Linear Microphone Array Based Source Separation for Conversion from Channel-based to Object-based Audio Content (채널 기반에서 객체 기반의 오디오 콘텐츠로의 변환을 위한 비균등 선형 마이크로폰 어레이 기반의 음원분리 방법)

  • Chun, Chan Jun;Kim, Hong Kook
    • Journal of Broadcast Engineering
    • /
    • v.21 no.2
    • /
    • pp.169-179
    • /
    • 2016
  • Recently, MPEG-H has been standardizing for a multimedia coder in UHDTV (Ultra-High-Definition TV). Thus, the demand for not only channel-based audio contents but also object-based audio contents is more increasing, which results in developing a new technique of converting channel-based audio contents to object-based ones. In this paper, a non-uniform linear microphone array based source separation method is proposed for realizing such conversion. The proposed method first analyzes the arrival time differences of input audio sources to each of the microphones, and the spectral magnitudes of each sound source are estimated at the horizontal directions based on the analyzed time differences. In order to demonstrate the effectiveness of the proposed method, objective performance measures of the proposed method are compared with those of conventional methods such as an MVDR (Minimum Variance Distortionless Response) beamformer and an ICA (Independent Component Analysis) method. As a result, it is shown that the proposed separation method has better separation performance than the conventional separation methods.

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

A sensor controller for map building of home service robot using low cost PSD sensor (저가형 PSD센서를 이용한 홈서비스 로봇의 Map building용 센서 제어시스템)

  • Hyun, Wong-Keun;Lee, Chang-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1897-1904
    • /
    • 2006
  • Home service robot must recognize and build map for indoor and components of the house such as furniture and chair etc. The previous researcher has developed a indoor map building system by using CCD camera and ultra sonic sensor. %no stems have some problem in such a way that (1) a distun resolution can be changed according to the number of pixel when we use a CCD camera system, (2) a measured distance can be decreased when it transmitted to the rubber because of being absorbed the sound energy. This paper represents an intelligent sensor controller of module has been developed by using optic PSD(Position Sensitive Detector) sensor any at a low price. To deduce the switching noise from beam power module and diffused reflection noise, we proposed a heuristic soft filter. The performance of the developed system was compared with ultra sonic sensor system by detecting the indoor wall environment. Some experiments were illustrated for the validity of the developed system.

Diagnostic Application of Temporomandibular Joint Disorder and Ultra Sound Guided Oral &Maxillofacial application (초음파를 이용한 턱관절질환의 진단과 초음파 가이드의 활용)

  • Seong, Tae-Hwan;Park, Jung-Hyun;Kim, Sun-Jong
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.789-799
    • /
    • 2017
  • Ultrasound images are noninvasive, can be observed in real time, have no radiation exposure, do not cause pain, and are not restricted in use depending on the patient's prosthetic implant or medical condition. Since the use of ultrasound in the dental field was first applied for tooth preparation in 1957, the use of diagnostic ultrasound for the first time in 1963 has been reported. Currently, it is used in the diagnosis of soft tissue lesions such as malignant tumor or salivary gland disease, fine needle aspiration test, temporomandibular joint disease, lymph node metastasis, measurement of muscle thickness and inflammatory diseases, differentiation of periapical cyst and granulation tissue, measurement of periodontal tissue thickness. The ultrasound image can be visualized in real time. The clinician can explain the structure to the patient while consulting the patient and consult the patient. When injecting the drug into a specific site or aspirating a specific site or substance, So that it can be confirmed and practiced. Recently, ultrasonic equipment specialized in the dental field has been developed and marketed, and it is expected that the use of ultrasonic waves will become active in the dentistry. In the future, development of popular equipment with size and frequency suitable for dental diagnosis and various researches on maxillofacial ultrasonic anatomy. If clinical studies are continuously carried out to demonstrate efficacy, ultrasound is expected to aid in accurate diagnosis and treatment throughout the dentistry.

  • PDF

Effect of ages and season temperatures on bi-surface shear behavior of HESUHPC-NSC composite

  • Yang Zhang;Yanping Zhu;Pengfei Ma;Shuilong He;Xudong Shao
    • Advances in concrete construction
    • /
    • v.15 no.6
    • /
    • pp.359-376
    • /
    • 2023
  • Ultra-high-performance concrete (UHPC) has become an attractive cast-in-place repairing material for existing engineering structures. The present study aims to investigate age-dependent high-early-strength UHPC (HESUHPC) material properties (i.e., compressive strength, elastic modulus, flexural strength, and tensile strength) as well as interfacial shear properties of HESUHPC-normal strength concrete (NSC) composites cured at different season temperatures (i.e., summer, autumn, and winter). The typical temperatures were kept for at least seven days in different seasons from weather forecasting to guarantee an approximately consistent curing and testing condition (i.e., temperature and relative humidity) for specimens at different ages. The HESUHPC material properties are tested through standardized testing methods, and the interfacial bond performance is tested through a bi-surface shear testing method. The test results quantify the positive development of HESUHPC material properties at the early age, and the increasing amplitude decreases from summer to winter. Three-day mechanical properties in winter (with the lowest curing temperature) still gain more than 60% of the 28-day mechanical properties, and the impact of season temperatures becomes small at the later age. The HESUHPC shrinkage mainly occurs at the early age, and the final shrinkage value is not significant. The HESUHPC-NSC interface exhibits sound shear performance, the interface in most specimens does not fail, and most interfacial shear strengths are higher than the NSC-NSC composite. The HESUHPC-NSC composites at the shear failure do not exhibit a large relative slip and present a significant brittleness at the failure. The typical failures are characterized by thin-layer NSC debonding near the interface, and NSC pure shear failure. Two load-slip development patterns, and two types of main crack location are identified for the HESUHPC-NSC composites tested in different ages and seasons. In addition, shear capacity of the HESUHPC-NSC composite develops rapidly at the early age, and the increasing amplitude decreases as the season temperature decreases. This study will promote the HESUHPC application in practical engineering as a cast-in-place repairing material subjected to different natural environments.