Effects of Electrotherapy on the Deactivation of Trigger points (전기치료가 발통점 비활성화에 미치는 효과)

  • Joung, Ho-Bal;Bang, Sang-Bun
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.2
    • /
    • pp.123-131
    • /
    • 2002
  • The purpose of this study is to compare Ultra Sound(U-S), Silver Spike Point(SSP) and Electro-Acupuncture(E-A) with each other and to objectively analyze their concrete validities and their effects on the deactivation of trigger points in patients with myofascial pain syndrome, and to provide basic necessary principles for clinical therapists. Sixty patients were randomly distributed into three groups of twenty persons each and the U-S, the SSP and the E-A were applied to each group respectively. Tree pain evaluation methods of VAS(Visual Analogue Scale), Electrical Stimulation Scale and Pressure Algometer were adopted to measure the effectiveness of each therapy. The results were as follows: The U-S and E-A groups demonstrated statistically significant decrease on the VAS. The pain thresholds by Electrical Stimulation Scale method was increased for all the groups of U-S, SSP and E-A with no statistical significance. however, Pressure Algometer method was found to increase the pain thresholds for both SSP and E-A groups with statistically significance. Statistically significant improvement was found for all the groups together after the administration of the U-S, the SSP and the E-A. From the above results, three methods of U-S, SSP and E-A are found to be effective tools for the deactivation of trigger points in patients with upper trapezius muscle of Myofascial Pain Syndrome. The E-A method was found to be the most effective among three methods.

  • PDF

Automatic Defect Detection and Classification Using PCA and QDA in Aircraft Composite Materials (주성분 분석과 이차 판별 분석 기법을 이용한 항공기 복합재료에서의 자동 결함 검출 및 분류)

  • Kim, Young-Bum;Shin, Duk-Ha;Hwang, Seung-Jun;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.4
    • /
    • pp.304-311
    • /
    • 2014
  • In this paper, we propose a ultra sound inspection technique for automatic defect detection and classification in aircraft composite materials. Using local maximum values of ultra sound wave, we choose peak values for defect detection. Distance data among peak values are used to construct histogram and to determine surface and back-wall echo from the floor of composite materials. C-scan image is then composed through this method. A threshold value is determined by average and variance of the peak values, and defects are detected by the values. PCA(principal component analysis) and QDA(quadratic discriminant analysis) are carried out to classify the types of defects. In PCA, 512 dimensional data are converted into 30 PCs(Principal Components), which is 99% of total variances. Computational cost and misclassification rate are reduced by limiting the number of PCs. A decision boundary equation is obtained by QDA, and defects are classified by the equation. Experimental result shows that our proposed method is able to detect and classify the defects automatically.

Efficient Extraction of efficient regions in ultrasound images (초음파 영상에서 효과적인 관심영역의 추출)

  • Kim, Tae-Sik;Kim, K-W
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.901-904
    • /
    • 2007
  • Nowadays, in many fields of medical treatment, we can make an observation and a diagnosis of inward disease without using a surgical operation. As one of them, ultra-sound diagnosis system can be available widely in its cost and size compared with other medical instruments. This system also make it possible for us to see the inner parts of the body in real time harmlessly for a long time. So it can be utilized to inspect the movement of heart or fetus and to diagnose an internal disease of the soft tissues. Ultra-sound images can be generated by the reflexive and scattered wave through the pulse generator and so in ultrasound images there exist inherently many affective noised signals. In this paper, we are to take an noise-restrained image and to extract a more affective regions of the images.

  • PDF

The Effects of Ultra Sound and Chuna in Patients with Lumbago by Meridian Muscle Electrography (혈위초음파요법과 추나요법이 요통환자 척추 기립근의 경근전도에 미치는 영향)

  • Cho, Dong-In;Yoon, Jeong-won;Park, Dong-Su;Kim, Soon-Joong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.4
    • /
    • pp.93-103
    • /
    • 2015
  • Objectives The purpose of this study is to compare the effects of ultra sound (U/S) and chuna on lumbago by meridian muscle electrography (MMEG). we performed U/S and chuna on erector spinae muscle. Methods This study was carried out on 20 lumbago patients. 20 patients were divided into U/S group and chuna group. U/S group take treatment 5 minutes. Chuna group take treatment 10 minutes. After performing U/S and chuna treatment 6 times, we compared both in terms of VAS, ODI, ROM, root mean square (RMS) and special edge frequency (SEF) on erector spinae muscle. The effect of each treatments are compared by Wilcoxon's signed rank test. The difference of effect between both groups are compared by Wilcoxon's rank-sum test. Results 1. Both U/S group and chuna group showed significant improvement in VAS and ODI after treatment. 2. U/S group showed insignificant improvement in both RMS and SEF. 3. Chuna group showed significant improvement in SEF at left lower point and RMS at left upper point. 4. Both U/S group and chuna group showed insignificant improvement in ROM. 5. There are no significant differences between both groups except SEF at left upper point. Conclusions According to above results, we found out that performing U/S or chuna on erector spinae muscle has effect in terms of VAS and ODI. But, in terms of SEF, we found out different result for both side. And we can't found out effect in terms of RMS and ROM of L-spine.

The effect of a desensitizer and $CO_2$ laser irradiation on bond performance between eroded dentin and resin composite

  • Ding, Meng;Shin, Sang-Wan;Kim, Min-Soo;Ryu, Jae-Jun;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.165-170
    • /
    • 2014
  • PURPOSE. This study was aimed to evaluate effect of the desensitizing pretreatments on the micro-tensile bond strengths (${\mu}TBS$) to eroded dentin and sound dentin. MATERIALS AND METHODS. Forty-two extracted molars were prepared to form a flat dentin surface, and then they were divided into two groups. Group I was stored in distilled water while group II was subjected to a pH cycling. Each group was then subdivided into three subgroups according to desensitizing pretreatment used: a) pretreatment with desensitizer (Gluma); b) pretreatment with $CO_2$ Laser (Ultra Dream Pluse); c) without any pretreatment. All prepared surfaces were bonded with Single Bond 2 and built up with resin composite (Filtek Z250). The micro-tensile bond test was performed. Fracture modes were evaluated by stereomicroscopy. Pretreated surfaces and bonded interfaces were characterized by scanning electron microscope (SEM). The data obtained was analyzed by two-way ANOVA (${\alpha}$=0.05). RESULTS. For both sound and eroded dentin, samples treated with desensitizer showed the greatest ${\mu}TBS$, followed by samples without any treatment. And samples treated with $CO_2$ laser showed the lowest ${\mu}TBS$. SEM study indicated that teeth with eroded dentin appeared prone to debonding, as demonstrated by existence of large gaps between adhesive layers and dentin. CONCLUSION. Pretreatment with Gluma increased the ${\mu}TBS$ of Single Bond 2 for eroded and sound teeth. $CO_2$ laser irradiation weakened bond performance for sound teeth but had no effect on eroded teeth.

Ultra Grain Refinement and High Strengthening of Deoxidized Low-Phosphorous Copper by Accumulative Roll-Bonding Process (ARB법에 의한 인탈산동의 결정립초미세화 및 고강도화)

  • Lee, Seong-Hee;Han, Seung-Zeon;Lim, Cha-Yong
    • Korean Journal of Materials Research
    • /
    • v.16 no.9
    • /
    • pp.592-597
    • /
    • 2006
  • A deoxidized low-phosphorous (DLP) copper was processed by accumulative roll-bonding (ARB) for ultra grain refinement and high strengthening. Two copper sheets 1 mm thick, 30 mm wide and 300 mm long are first degreased and wire-brushed for sound bonding. The sheets are then stacked to each other, and roll-bonded by about 50% reduction rolling without lubrication at ambient temperature. The bonded sheet is then cut to the two pieces of same dimensions and the same procedure was repeated to the sheets up to eight cycles (${\varepsilon}{\sim}6.3$). TEM observation revealed that ultrafine grains were developed after the 4th cycle, and their size decreased at higher cycles. Tensile strength of the copper increased with the equivalent strain, and it reached 547 MPa which was 3 times higher than that of the initial material. It is concluded that the ARB process is an effective method for high strengthening of the DLP copper.

Proposal of a non-coherent Communication Protocol with Ultra Sonic which can Improve the Communication Speed (넌코히어런트 전송 방식에서 초음파를 이용한 디지털 통신속도 개선 프로토콜 제안)

  • Yoon, Byung-Woo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Propagation of electromagnetic wave in the water or underground is very difficult because of the conductivity of the propagation materials. In this case, we usually use acoustic signal as ultrasonic but, it is not easy to transfer long distance with coherent method because of time varying multipath, doppler effect, and attenuations. So, we use noncoherent method as FSK to communicate between long distances. But, as the propagation speed of acoustic sound is very slow, the BW of the channel is narrow. It is very hard to guaranty the enough speed of communication like digital image data. In this paper, we proposed a new data communication protocol which can transmit multi-bit digital data with every single ping, and improve the data communication speed in the water.

  • PDF

Using Acoustic Liner for Fan Noise Reduction in Modern Turbofan Engines

  • Azimi, Mohammadreza;Ommi, Fathollah;Alashti, Naghmeh Jamshidi
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.1
    • /
    • pp.97-101
    • /
    • 2014
  • With the increase in global air travel, aircraft noise has become a major public issue. In modern aircraft engines, only a small proportion of the air that passes through the whole engine actually goes through the core of the engine, the rest passes around it down the bypass duct. A successful method of reducing noise further, even in ultra-high bypass ratio engines, is to absorb the sound created within the engine. Acoustically absorbent material or acoustic liners have desirable acoustic attenuation properties and thus are commonly used to reduce noise in jet engines. The liners typically are placed upstream and downstream of the rotors (fans) to absorb sound before it propagates out of the inlet and exhaust ducts. Noise attenuation can be dramatically improved by increasing the area over which a noise reducing material is applied and by placing the material closer to the noise source. In this paper we will briefly discuss acoustic liner applications in modern turbofan engines.

Characteristics of the Functional Panel Made from Foamed Aluminum (발포알루미늄을 이용하여 제조한 기능성 판넬 특성 연구)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2006
  • In this work, the properties of environmentally friendly functional panel made from waste aluminum were investigated. Product quality enhancement was pursued through an improved viscosity process, a mixing process by agitating, a foaming process, a cooling process, and a color addition process. An acoustic transmission attenuation test, a sound adsorption rate measurement test, and a foaming condition and scrap mixing test were implemented. As a result, the functional panel made from waste aluminum was ultra lightweight and had excellent properties such as soundproof, sound interception, and shielding harmful electromagnetic waves. Also, the functional panel showed low thermal conductivity (about 2.2 kcal/mh) and excellent heat-insulating property.

Prototype Model Design and Implementation of Fetal Heart Sound Measurement Device (심장 초음파 측정기의 프로토 타입 모델 설계 및 구현)

  • Choi, Sung-Jai
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.111-116
    • /
    • 2022
  • In the paper, A prototype Fetal Heart Monitor, mini - size, was designed and produced for pre-mothers to measure the rate and rhythm of their features's heart at home.Pre-mothers could listen fetal heart rhythm through an inner bluetooth speaker ant the monitor. LED colors show the frequency of fetal heart rate variability on the monitor. All measured health information, by ultrasonic resonator and bluetooth speaker, is linked to a mother's smart phone. A test verified this simple measuring device helps users discover the symptoms of fetal health. Patients using at home devices usefully prevent sudden cardiac death and myocardial infraction by discovering symptoms.