• Title/Summary/Keyword: Uca

Search Result 64, Processing Time 0.03 seconds

Preparation of Biomass Based Carbon for Electrochemical Energy Storage Application

  • Harshini Priyaa, V.S.;Saravanathamizhan, R.;Balasubramanian, N.
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.159-169
    • /
    • 2019
  • The activated carbon materials were prepared from waste biomass by ultrasonic assisted chemical activation method (UCA), ultrasonic assisted physical activation method (UPA) and Manganese nitrogen doped carbon (Mn/N-C). The XRD result shows the turbostatic (fully disordered) structure. The cyclic voltammetry test was done at 50 mV/s using 1M sodium sulfate and the values of specific capacitance were found to be 93, 100 and 115 F/g for UCA, UPA and Mn/N-C respectively. The power density values for the samples UCA, UPA and Mn/N-C were found to be 46.04, 87.97 and 131.42 W/kg respectively. The electrochemical impedance spectroscopy was done at low frequency between 1 to 10 kHz. The Nyquist plot gives the resistant characteristics of the materials due to diffusional resistance at the electrode-electrolyte interface. The Energy Dispersive X-Ray Spectroscopyanalysis (EDAX) analysis showed that the percentage doping of nitrogen and manganese were 3.53 wt% and 9.44 wt% respectively. It is observed from the experiment Mn/N-C doped carbon show good physical and electrochemical properties.

Spatial Spectrum Estimation of Incident Signal Via Measured Array Manifold (측정 Array Manifold를 적용한 입사 신호의 공간 스펙트럼 추정)

  • 강흥용;이성윤;김영수;김창주;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.223-230
    • /
    • 2004
  • A method for measuring array manifold which is the array antenna response of incident signal is presented. Array manifold measurement procedure by the presented method is explained for UCA(Uniform Circular Array), and spatial spectrum of 300 ㎒ tone signal incident on UCA is estimated by MUSIC algorithm in which spatial spectrum peak is searched with measured array manifold. Spatial spectrum estimation using array manifold measured by the proposed method shows superior performance to calculated array manifold.

Primary Radiation Force to Ultrasound Contrast Agents in Propagating and Standing Acoustic Field

  • Seo, Jong-Bum
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1E
    • /
    • pp.1-8
    • /
    • 2009
  • Primary radiation force on ultrasound contrast agents (UCA) in a propagating and standing acoustic field was explored. A specific ultrasound contrast agent $Albunex^{(R)}$ and $Optison^{(R)}$ were chosen for simulation. The model was developed based on a shelled bubble model proposed by Church. The numerical simulation suggests that bubble translational motion is more significant in therapeutic ultrasound due to higher intensity and long pulse duration. Even a single cycle of a propagating wave of 4 MPa at 1 MHz can cause a bubble translational motion of greater than $1{\mu}m$ which is approximately one tenth of capillary. Hence, UCA characteristics can be significantly changed in therapeutic ultrasound without rapid bubble collapses.

The Brachyuran Crabs (Crustacea ; Decapoda) of Chindo Island , Korea (진도의 게류(갑각상강: 십각목))

  • Won Kim;Sa Heung Kim
    • Animal Systematics, Evolution and Diversity
    • /
    • v.11 no.4
    • /
    • pp.497-508
    • /
    • 1995
  • The ten species , Nobilum japonicum japonicum , Paradorippe granulata, Pilumnus minutes, Carcinoplax vestitus, Eucrate crenata, Uca lactea. Ilyoplax pingi, Nanosesarma gordoni, Achaeus tuberculatus, Parthenope validus, are added to the brachyuran fauna of the Chindo Island and its adjacent islets. With the previsouly known 36 species , total 46 speices from the Chindio I. and its adjacentislets are listed and two grapsid species, Hemigrapsus longitarsis and Sesarma erythrodactyla , are redescribed with illustrations.

  • PDF

The Survey for Communication Protocols adopted by Automation Systems In Electric Power Companies (전력자동화용 통신프로토콜 현황 및 분석)

  • Kim, Myong-Soo;Lim, Yong-Hun;Hyun, Duck-Hwa;Kim, Chung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2349-2351
    • /
    • 2003
  • Over the past $2{\sim}3$ years power utilities have shown a marked change in attitude by an ever increasing interest in using relay communication features. As yet there is no accepted international standard for communication protocol in automation systems. Recent work within the UCA work group has resulted in the proposal, UCA 2.0, as the informative interface for automation systems. This proposed standard embodies the generic principles developed and used within generic protocol. This paper describes and analyses various communication protocols for automation systems in electric power companies.

  • PDF

ESPRIT target position estimation with uniform linear array and uniform circular array (등간격 선형어레이와 등간격 원형어레이 레이더를 위한 ESPRIT 표적 위치 추정 기법)

  • NamGoong, Geol;Lim, Jong-Tae;Yoo, Do-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.6
    • /
    • pp.952-959
    • /
    • 2012
  • In this paper, we propose an ESPRIT based algorithm for target position estimation with uniform linear array (ULA) and uniform circular array (UCA) at transmitter and receiver, respectively. When UCA is adopted at the receiver, unlike the case of ULA at the receiver, the rotational invariance of the received signal is satisfied. Although there has been an attempt to resolve this issue, the problem of direction of departure estimation has not been considered. In this paper, we provide an ESPRIT based algorithm to simultaneously estimate transmitter elevation angle, receiver elevation angle, and receiver azimuth angle, taking into account the transmitter antennas as well as the receiver antennas.

Performance Analysis of Cascade AOA Estimator with Concentric Ring Array Antenna (동심원 배열 안테나를 적용한 캐스케이드 도래각 추정 성능분석)

  • Kim, Tae-Yun;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.5
    • /
    • pp.849-856
    • /
    • 2020
  • The Angle-of-Arrival(AOA) information for an array antenna receiver is one of the important factors for estimating the location of specific signals and detecting signals efficiently, in various situations. The AOA estimator in the satellite environment can rapidly calculate the AOA information in the wide area, utilizing a planar (grid, circular) array antenna mounted on the satellite. Since the satellite receiver has the limitation of the array antenna size, the concentric circular (ring) array (CCA or CRA) antenna structure with comparatively small size but with multiple antenna elements is more efficient than the uniform circular array (UCA) structure, for the satellite environment. In this paper, we introduce a cascade AOA estimation algorithm based on CRA, consisting of CAPON and Beamspace MUSIC. In addition, we provide computer simulation examples for verifying the estimation performance of the cascade AOA estimation algorithm based on CRA and compare it to the case of UCA.

Detection of Incidental Prostate Cancer or Urothelial Carcinoma Extension in Urinary Bladder Cancer Patients by Using Multiparametric MRI: A Retrospective Study Using Prostate Imaging Reporting and Data System Version 2.0 (방광암 환자의 다중 매개 자기공명영상에서 우연히 발견된 전립선암 또는 요로상피세포암종의 전립선 침범의 검출: 전립선 이미징 보고 및 데이터 시스템 버전 2.0을 사용한 후향적 연구)

  • Sang Eun Yoon;Byung Chul Kang;Hyun-Hae Cho;Sanghui Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.610-619
    • /
    • 2020
  • Purpose The study aimed to investigate the role of Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) in predicting incidental prostate cancer (PCa) or urothelial carcinoma (UCa) extension in urinary bladder (UB) cancer patients. Materials and Methods A total of 72 UB cancer patients who underwent radical cystoprostatectomy and 3 Tesla multiparametric MRI before surgery were enrolled. PI-RADS v2 ratings were assigned by two independent radiologists. All prostate specimens were examined by a single pathologist. We compared the multiparametric MRI findings rated using PI-RADS v2 with the pathologic data. Results Of the 72 UB cancer patients, 29 had incidental PCa (40.3%) and 20 showed UCa extension (27.8%), with an overlap for 3 patients. With a score of 4 as the cut-off value for predicting incidental PCa, the diagnostic accuracy was 65.3%, specificity was 90.7%, and positive predictive value (PPV) was 66.7%. The diagnostic accuracy for incidental UCa extension was 47.2%, specificity was 92.3%, and PPV was 83.3%. Conclusion Despite the low diagnostic accuracy, the PPV and specificity were relatively high. Therefore, PI-RADS v2 scores of 1, 2, or 3 may help exclude the probability of incidental PCa or UCa extension.