• Title/Summary/Keyword: UV-absorption

Search Result 1,095, Processing Time 0.026 seconds

Effect of temperature on pharmacokinetics of nalidixic acid and piromidic acid in black rockfish Sebastes schlegeli following oral administration (조피볼락, Sebastes schlegeli에 경구투여된 nalidixic acid 및 piromidic acid의 약물동태에 미치는 수온의 영향)

  • Jung, Sung-Hee;Seo, Jung-Soo;Jee, Bo-Young;Kim, Jin-Woo;Park, Myoung-Ae
    • Journal of fish pathology
    • /
    • v.24 no.1
    • /
    • pp.29-37
    • /
    • 2011
  • Effects of temperature ($13{\pm}1.5^{\circ}C$, $23{\pm}1.5^{\circ}C$) on the pharmacokinetic properties of nalidixic acid (NA) and piromidic acid (PA) were studied after oral administration to cultured black rockfish, Sebastes schlegeli. Serum concentrations of NA and PA were determined using HPLC-UV detector after a single dosage of 60 mg/kg body weight. At $23{\pm}1.5^{\circ}C$, the peak serum concentrations of NA and PA, which attained at 24 h post-dose, were 5.87 and $0.43\;{\mu}g/ml$, respectively. At $13{\pm}1.5^{\circ}C$, the peak serum concentrations of NA and PA, which attained at 10 h post-dose, were 6.22 and $1.57\;{\mu}g/ml$, respectively. Better absorption of PA was noted at $13{\pm}1.5^{\circ}C$ compared to $23{\pm}1.5^{\circ}C$. However, absorption of NA was not affected significantly by temperature. The elimination of NA and PA from serum of black rockfish was considerably faster at $23{\pm}1.5^{\circ}C$ than at $13{\pm}1.5^{\circ}C$. The kinetic profile of absorption, distribution and elimination of NA and PA in serum were analyzed by fitting to a one compartment model, with WinNonlin program. The AUC, $T_{1/2}$, $T_{max}$ and $C_{max}$, respectively, were: $161.25\;{\mu}g{\cdot}h/ml$, 0.15 h, 12.29 h and $8.91\;{\mu}g/ml$ at $23{\pm}1.5^{\circ}C$, and $134.12{\mu}g{\cdot}h/ml$, 0.18 h, 8.79 h and $5.00\;{\mu}g/ml$ at $13{\pm}1.5^{\circ}C$ with NA; $41.57\;{\mu}g{\cdot}h/ml$, 0.58 h, 8.24 h and $0.21\;{\mu}g/ml$ at $23{\pm}1.5^{\circ}C$, and $40.36\;{\mu}g{\cdot}h/ml$, 0.59 h, 5.04 h and $1.20\;{\mu}g/ml$ at $13{\pm}1.5^{\circ}C$ with PA.

UVB-Shielding Effects of para-Coumaric Acid (파라-쿠마린산의 자외선B 차단 효과)

  • Song, Kyo-Sun;Boo, Yong-Chool
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.3
    • /
    • pp.263-273
    • /
    • 2012
  • Recent studies have uncovered attractive properties of para-coumaric acid (PCA) as a potential skin hywhitening agent. The purpose of the current study was to examine its UVB-shielding effects. Effects of PCA on the viability of HaCaT cells exposed to UVB were assessed in vitro in comparison with other aromatic amino acid metabolites that have similar UV absorption spectra. For in vivo test, PCA cream (1.5 %) and cream base were topically applied to the dorsal skin of SKH-1 hairless mice and the inflammatory responses due to UVB exposure were monitored by changes in skin color (erythema) and thickness (edema). The cream application-UVB exposure regimen was repeated every other day for a total of 12 sessions. When HaCaT cells were irradiated with UVB, there was a dose-dependent decline in cell viability. The cell viability decline due to UVB exposure (10 mJ $cm^{-2}$) was significantly prevented by 100 ${\mu}M$ PCA, cinnamic acid, urocanic acid, or indole acrylic acid by 39, 27, 39, or 31 %, respectively. Topical application of PCA cream onto the dorsal skin of hairless mice (10 ${\mu}g\;cm^{-2}$) attenuated the changes of color parameters, $L^*$, $a^*$, $b^*$ values, and thickness of the UVB (150 mJ $cm^{-2}$)-exposed skin by 59, 50, 58, and 53 %, respectively. The current study, together with the previous studies that demonstrated the antimelanogenic effects of PCA, suggested that PCA may prevent not only dyspigmentation but also inflammatory reactions in the UVB-exposed skin.

Tri-branched tri-anchoring organic dye for Visible light-responsive dye-sensitized photoelectrochemical water-splitting cells (염료감응형 광전기화학 물분해 전지용 Tri-branched tri-anchoring organic dye 개발)

  • Park, Jeong-Hyun;Kim, Jae-Hong;Ahn, Kwang-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.87-87
    • /
    • 2010
  • Photoelectrochemical (PEC) systems are promising methods of producing H2 gas using solar energy in an aqueous solution. The photoelectrochemical properties of numerous metal oxides have been studied. Among them, the PEC systems based on TiO2 have been extensively studied. However, the drawback of a PEC system with TiO2 is that only ultraviolet (UV) light can be absorbed because of its large band gap (3.2 - 3.4 eV). Two approaches have been introduced in order to use PEC cells in the visible light region. The first method includes doping impurities, such as nitrogen, into TiO2, and this technique has been extensively studied in an attempt to narrow the band gap. In comparison, research on the second method, which includes visible light water splitting in molecular photosystems, has been slow. Mallouk et al. recently developed electrochemical water-splitting cells using the Ru(II) complex as the visible light photosensitizer. the dye-sensitized PEC cell consisted of a dye-sensitized TiO2 layer, a Pt counter electrode, and an aqueous solution between them. Under a visible light (< 3 eV) illumination, only the dye molecule absorbed the light and became excited because TiO2 had the wide band gap. The light absorption of the dye was followed by the transfer of an electron from the excited state (S*) of the dye to the conduction band (CB) of TiO2 and its subsequent transfer to the transparent conducting oxide (TCO). The electrons moved through the wire to the Pt, where the water reduction (or H2 evolution) occurred. The oxidized dye molecules caused the water oxidation because their HOMO level was below the H2O/O2 level. Organic dyes have been developed as metal-free alternatives to the Ru(II) complexes because of their tunable optical and electronic properties and low-cost manufacturing. Recently, organic dye molecules containing multi-branched, multi-anchoring groups have received a great deal of interest. In this work, tri-branched tri-anchoring organic dyes (Dye 2) were designed and applied to visible light water-splitting cells based on dye-sensitized TiO2 electrodes. Dye 2 had a molecular structure containing one donor (D) and three acceptor (A) groups, and each ended with an anchoring functionality. In comparison, mono-anchoring dyes (Dye 1) were also synthesized. The PEC response of the Dye 2-sensitized TiO2 film was much better than the Dye 1-sensitized or unsensitized TiO2 films.

  • PDF

Fabrication of Schottky Device Using Lead Sulfide Colloidal Quantum Dot

  • Kim, Jun-Kwan;Song, Jung-Hoon;An, Hye-Jin;Choi, Hye-Kyoung;Jeong, So-Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.189-189
    • /
    • 2012
  • Lead sulfide (PbS) nanocrystal quantum dots (NQDs) are promising materials for various optoelectronic devices, especially solar cells, because of their tunability of the optical band-gap controlled by adjusting the diameter of NQDs. PbS is a IV-VI semiconductor enabling infrared-absorption and it can be synthesized using solution process methods. A wide choice of the diameter of PbS NQDs is also a benefit to achieve the quantum confinement regime due to its large Bohr exciton radius (20 nm). To exploit these desirable properties, many research groups have intensively studied to apply for the photovoltaic devices. There are several essential requirements to fabricate the efficient NQDs-based solar cell. First of all, highly confined PbS QDs should be synthesized resulting in a narrow peak with a small full width-half maximum value at the first exciton transition observed in UV-Vis absorbance and photoluminescence spectra. In other words, the size-uniformity of NQDs ought to secure under 5%. Second, PbS NQDs should be assembled carefully in order to enhance the electronic coupling between adjacent NQDs by controlling the inter-QDs distance. Finally, appropriate structure for the photovoltaic device is the key issue to extract the photo-generated carriers from light-absorbing layer in solar cell. In this step, workfunction and Fermi energy difference could be precisely considered for Schottky and hetero junction device, respectively. In this presentation, we introduce the strategy to obtain high performance solar cell fabricated using PbS NQDs below the size of the Bohr radius. The PbS NQDs with various diameters were synthesized using methods established by Hines with a few modifications. PbS NQDs solids were assembled using layer-by-layer spin-coating method. Subsequent ligand-exchange was carried out using 1,2-ethanedithiol (EDT) to reduce inter-NQDs distance. Finally, Schottky junction solar cells were fabricated on ITO-coated glass and 150 nm-thick Al was deposited on the top of PbS NQDs solids as a top electrode using thermal evaporation technique. To evaluate the solar cell performance, current-voltage (I-V) measurement were performed under AM 1.5G solar spectrum at 1 sun intensity. As a result, we could achieve the power conversion efficiency of 3.33% at Schottky junction solar cell. This result indicates that high performance solar cell is successfully fabricated by optimizing the all steps as mentioned above in this work.

  • PDF

Effect of Preservation Conditions on the Stability of Samul-tang Decoctions (사물탕 전탕액의 보관 조건에 따른 안정성 분석)

  • Park, In Hwa;Kim, Yeon Hak;Choi, Seong Hwan;Yu, Sun Nyoung;Kim, Sang Hun;Ahn, Soon Cheol;Cho, Su In;Lee, In
    • Journal of Life Science
    • /
    • v.25 no.10
    • /
    • pp.1124-1131
    • /
    • 2015
  • Consumer interest in the stability of medicinal herb extracts during storage has increased. Although the advent of new technologies has improved preservation conditions, increasing the storage time, there are few studies on the preservation of herb extracts. The purpose of this study was to perform microscopic observations of Samul-tang decoctions under various preservation conditions. The storage temperature (a high temperature, room temperature, with or without light, refrigeration, or cryopreservation) and storage time (0, 15, 30, 90, and 180 days) were given to each condition Macroscopic morphology, pH, UV absorption, HPLC, and bacteriological studies were performed to determine microscopic changes in Samul-tang decoctions. The biological activity (tyrosinase inhibition) of the Samul-tang decoctions was also examined. There were no major changes in the indicated observation items when the extracts were stored in each condition. However, at higher storage temperatures and longer storage times, microscopic changes increased, although no bacteria were detected. Furthermore, the higher the storage temperature was and the longer the storage time was, the bigger the change was, despite of minor microscopic changes. Therefore, to maintain the stability of herbal extracts during storage, it is recommended to keep the Samul-tang decoction in the preservation condition of refrigeration and cryopreservation or without light rather than high temperature and room temperature as possible.

Determination of Pantothenic acid in Fortified Foods by HPLC (시판 영양강화식품중 판토텐산의 분석)

  • 최윤주;장재희;박혜경;박건상;구용의;황인경;김대병
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.381-385
    • /
    • 2004
  • This study was conducted to develop an HPLC method for determining pantothenic acid in fortified foods which has typically been determined by microbiological assay (MBA) according to AOAC and Korean Food Code approved methods. Pantothenic acid was determined by reversed-phase ion-pair HPLC using UV absorption (200 nm) after extraction with 20 mM potassium phosphate solution by sonication. The recovery of spiked samples and detection limit (LOD) by HPLC were 83.5∼109.6% and 0.5 ppm (mg/kg), respectively. The LOD of the microbiological assay (MBA) was much lower than that of HPLC. The concentrations of pantothenic acid analyzed in all tested samples (n=13) confirmed compliance with declared label claims. The range of recovery ratio by the HPLC method when compared to the microbiological assay was 91.9∼117.6%. There was not significant difference (p<0.01) between the HPLC and MBA methods and the equation of the regression curve was y=1.1428x-0.2269 (r=0.9842). This proposed HPLC method for determining pantothenic acid appears to be suitable for determining pantothenic acid concentrations above 0.25 mg/100 g in fortified foods.

Defect center of $Li^{+}$ ion implanted $Al_2O_3$ ($Li^{+}$ 이온 주입된 $Al_2O_3$의 결함 특성)

  • Kim, Tae-Kyu
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The thermoluminescence(TL) glow curves and the optical absorption of $Al_2O_3$ irradiated with ${\gamma}$-ray, electron, and $Li^{+}$ ion followed by electron irradiation have been investigated to determine the relation of TL peak to its defect type. The TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows TL peaks at 380 K, 415 K, and 475 K. The UV photobleached TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows that the 380 K and 475 K TL peaks completely disappear while the 415 K TL peak still exists. The electron beam induced TL glow curve of $Al_2O_3$ after $Li^{+}$ ion implantation shows that the TL peak at 440 K is enhanced by a factor of 2 over the TL intensity of unimplanted $Al_2O_3$ while the TL peak at 380 K evidently disappears The implanted $Li^{+}$ ions are assumed to form singly charged interstitial cations and then recombine with electron trapped in F centers to produce F+ centers. The 380 K and 475 K TL peaks are proposed to be associated with F center, while the 415 K and 440 K TL peak are connected with F$^{+}$ center.

  • PDF

Prediction of Optimum Fertilizer Rate for Flue-Cured Tobacco by Nitrogen Availability in Soils (토양질소(土壤窒素)의 유효도(有效度) 검정방법(檢定方法)에 의한 황색종연초(黃色種煙草)의 적정시비량(適正施肥量) 추정(推定))

  • Jeong, Hun-Chae;Cho, Seong-Jin;Hong, Sun-Dal;Lee, Yun-Hwan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.18 no.2
    • /
    • pp.169-176
    • /
    • 1985
  • Six analytial methods for determing the available nitrogen in soils were tested to predict the optimum fertilizer rate for the flue-cured tobacco and to test the fertility level of soils for tobacco. All methods, nitrifiable $NO_3-N$ value for 2 and 4 weeks incubation, UV absorption value at 260nm and N-value in acid digestion of 0.01 M-$NaHCO_3$ extracts, N-value extracted in boiling with $CaCl_2$ solution, and autoclave-extractable $NH_4-N$ value in 0.01 M-$CaCl_2$, were closely correlated with total nitrogen uptake as well as yield. Therefore available nitrogen indices determined from above 6 analysis method could be used for the predicting of tobacco yield without fertilizer, criteria for fertility class, and recommendable range of optimum fertilization.

  • PDF

Sensitivity Analysis of Satellite BUV Ozone Profile Retrievals on Meteorological Parameter Errors (기상 입력장 오차에 대한 자외선 오존 프로파일 산출 알고리즘 민감도 분석)

  • Shin, Daegeun;Bak, Juseon;Kim, Jae Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.481-494
    • /
    • 2018
  • The accurate radiative transfer model simulation is essential for an accurate ozone profile retrieval using optimal estimation from backscattered ultraviolet (BUV) measurement. The input parameters of the radiative transfer model are the main factors that determine the model accuracy. In particular, meteorological parameters such as temperature and surface pressure have a direct effect on simulating radiation spectrum as a component for calculating ozone absorption cross section and Rayleigh scattering. Hence, a sensitivity of UV ozone profile retrievals to these parameters has been investigated using radiative transfer model. The surface pressure shows an average error within 100 hPa in the daily / monthly climatological data based on the numerical weather prediction model, and the calculated ozone retrieval error is less than 0.2 DU for each layer. On the other hand, the temperature shows an error of 1-7K depending on the observation station and altitude for the same daily / monthly climatological data, and the calculated ozone retrieval error is about 4 DU for each layer. These results can help to understand the obtained vertical ozone information from satellite. In addition, they are expected to be used effectively in selecting the meteorological input data and establishing the system design direction in the process of applying the algorithm to satellite operation.

Bioavailability of Cefaclor Capsules Using an Improved Analytical Method of Cefaclor in Human Plasma (개선된 사람 혈장중 세파클러 농도 정량법을 이용한 세파클러 캡슐의 생체이용률 측정)

  • Kim, Tae-Wan;Song, Ok-Kyoung;Han, Sun-Young;Cao, Qing-Ri;Park, Mi-Jin;Kang, Sung-Ha;Shin, Kwan-Seog;Cui, Jing-Hao;Lee, Beom-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • After establishing improved HPLC analytical method of cefaclor in human plasma samples, a bioavailability study of cefaclor capsules was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). The standard calibration curve using an HPLC with UV detector was constructed in a range of $0.0324{\sim}16\;{\mu}g/ml$. The 6% perchloric acid instead of 6% trichloroacetic acid was used to precipitate plasma protein. The HPLC chromatograms were precisely and accurately resolved when spiked with human plasma spiked with cefaclor and cephalexin (internal standard). Twenty healthy male Korean volunteers received two commercial cefaclor capsules, $Neocef^{\circledR}$ capsule (Jinyang Pharm. Co., Ltd) or $Ceclor^{\circledR}$ capsule (Lilly Korea. Co., Ltd.) at the 250 mg cefaclor in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of cefaclor were monitored for 8 hours after oral drug administration. $AUC_t$ the area under the plasma concentration-time curve from time zero to 8 hr (13 points), was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the cross-over design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Neocef^{\circledR}/Ceclor^{\circledR}$ were $0.9049{\leq}{\delta}{\leq}1.226$, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Neocef^{\circledR}/Ceclor^{\circledR}$ with respect to the extent of absorption.