• Title/Summary/Keyword: UV-Vis method

Search Result 601, Processing Time 0.034 seconds

Analysis of Chlorine Species in Chlorine Dioxide Bleaching Liquor and Generation Process by UV-VIS Spectroscopy

  • Wang, Li-Jun;Lee, Seon-Ho;Yoon, Byung-Ho
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04a
    • /
    • pp.78-83
    • /
    • 1999
  • In this paper the extinction coefficients of molecule chlorine ($Cl_2$), chlorine dioxide (ClO$_2$), hypochlorous acid (HClO), chlorous acid ($HClO_2$$_2$) were determined using a PDA UV-VIS spectrophotometer. Based on these, the concentrations of $Cl_2$, $ClO_2$, and HClO in general chlorine dioxide bleaching liquor can be measured. The concentrations of $Cl_2$, $ClO_2$ and $HClO_2$ produced during the generation of methanol based chlorine dioxide generator can also be determined use the same method. The method was thought to be able to give more information in chlorine dioxide bleaching chemistry if combine its use with titration and ion chromatography.

  • PDF

Synthesis and Photoisomerization Properties of Polynorbornenes with Azobenzene Chromophores

  • Kang, Suk-Hoon;Shin, Hee-Deuk;Oh, Cha-Hwan;Choi, Dong-Hoon;Park, Ki-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.7
    • /
    • pp.957-963
    • /
    • 2002
  • We successfully synthesized the addition-type polynorbonenes (PNB) exhibiting photochromic properties and excellent thermal stability. Three norbornene-based monomers with different azobenzene moiety (R=NO2, H,OCH3) were synthesized by transesterification method. The corresponding PNB copolymers were synthesized by transition metal-catalyzed addition polymerization method, and characterized by GPC, UV-Vis spectroscopy, NMR, and thermal analysis. For comparison of the photochromic properties depending on the rigidity of polymer backbone, we prepared the polymethylmethacrylate (PMMA) copolymer with the corresponding azobenzene moiety. We investigated the photoisomerization behavior by means of optical muitichannel analyzer with Xe lamp as well as real-time UV-Vis spectroscopy with high-pressure mercury lamp. Among three PNB copolymers, a polymer with azobenzene (R=H) was the most adaptable for observation of photoisomerization behavior. It was found that the rate of photoisomerization and relaxation depended on the structure of azobenzene chromophore, rather than that of polymer backbone.

Simple Analysis for Interaction between Nanoparticles and Dye-Containing Vesicles as a Biomimetic Cell-Membrane

  • Shin, Sohyang;Umh, Ha Nee;Kim, Younghun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.231-236
    • /
    • 2013
  • Some cytotoxicity studies for the interpretation of the interaction between nanoparticles and cells are non-mechanistic and time-consuming. Therefore, non-biological screening methods, which are faster and simpler than in-vivo and in-vitro methods, are required as alternatives to current cytotoxicity tests. Here, we proposed a simple screening method for the analysis of the interaction between several AgNPs (bare-, citrate-, and polyvinylpyrrolidone-coating) and dye-containing vesicles acting as a biomimetic cell-membrane. The interaction between AgNPs and vesicles could be evaluated readily by UV-vis spectra. Absorbance deviation in UV-vis spectra revealed a large attraction between neighboring particles and vesicles. This was confirmed by (Derjagin, Landau, Verwey, and Overbeek) theory and DMF (dark-field microscopy) analysis. This proposed method might be useful for analyzing the cytotoxicity of nanoparticles with cell-membranes instead of in vitro or in vivo cytotoxicity tests.

Spectrophotometric Determination of Amantadine Sulfate after Ion-Pairing with Methyl Orange

  • Choi, Kyong;Choi, Jung-Kap;Yoo, Gyurng-Soo
    • Archives of Pharmacal Research
    • /
    • v.14 no.4
    • /
    • pp.285-289
    • /
    • 1991
  • A convenient spectrophotometric method was examined for the determination of amantadine sulfate (AMTS) which has no UV-VIS chromopohores. AMTS was ion-paired quantitatively with methyl orange (MO) at $70^{\circ}C$ for 30 min. The ion-paired complex was extracted with dichloromethane and the absorbance was measured at 421.5 nm. A linear relationship was observed in the range of $2.5{\times}10^{-7}\;M$ to $3.75{\times}10^{-6}\;M$ and the correlation coefficient was 0.999 (n=3). This assay method was applied to the quantification of AMTS in commercial tablet form with good recovery and high precision.

  • PDF

A Study on Ultrasonic Transducer displacement generator by Frequency Phase modulation (주파수 위상 변조에 의한 초음파 탐촉자 변위 발생기에 관한 연구)

  • 김정래
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.3
    • /
    • pp.36-41
    • /
    • 2002
  • This study was carried out develope a ultrasonic transducer displacement generator through 26KHz and 38KHz of the frequency phase modulation on the ultrasonic transducer. This system was producted a power output generation such as 100W, 300W, 400W and 600W. Ultrasonic power output had a change of time. We made use of a Thiram hydration and detected it measurement by the ACAO method. It was to decide the result of ultrasonic power supply for time duration and the result of comparison in the 26KHz & 38KHz by UV/VIS spectrophotometer.

  • PDF

Analysis of gibberellic acid from fruits using HPLC/UV-vis (HPLC/UV-vis을 이용한 과일류 중의 지베렐린 산 분석)

  • Ma, Kyung Na;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • Gibberllic acid ($GA_3$) is one of gibberellins (GAs) that are a class of plant growth hormones that exert profound and diverse effects on plant growth and development. $GA_3$ is essentially non-UV absorbing and is difficult to assay by UV-detector. For effective extraction of gibberellic acid from fruits by using liquid-liquid extraction, optimized pH and extraction solvent were established. The selective and sensitive derivative of $GA_3$ for HPLC/UV-vis was derivatized using phenacyl bromide, and the experimental factors, including reaction time, reaction temperature and amount of derivatizing reagent and base were investigated for the effective synthesis. The derivatized $GA_3$ with phenacyl bromide was effectively analyzed by HPLC/UV-vis. The structure of derivatized $GA_3$ was confirmed by HPLC/ESI-MS. For apple, LOD and LOQ were 0.008 mg/kg and 0.027 mg/kg, respectively. For pear, LOD and LOQ were 0.003 mg/kg, 0.012 mg/kg, respectively. The established method can be applied to more effective analysis of $GA_3$ from plant and food.

A Study of Interference Factor of Analysis Method of Hexavalent Chromium in Soil using UV/VIS Spectrometry and Application of Ion Chromatography (자외선/가시선 분광법을 이용한 토양 중 6가 크롬 분석방법의 방해요인 분석 및 이온크로마토그래피 적용에 관한 연구)

  • Noh, Hoe-Jung;Lee, Myung-Gyu;Lee, Hyeon Seok;Kim, Mira;Kim, Dongho;Kim, Tae Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.33-42
    • /
    • 2012
  • This study was performed to find the problems according to interference factors (organic matter, pH, Cr, Mn, Fe, clay, and etc.) when we analyzed the hexavalent chromium [Cr(VI)] in soils using UV/VIS spectrometer (US EPA 7196A), attempted to evaluate the domestic applicability of analytical method (US EPA 7199) using IC-UV/VIS spectrometer as alternative method. The recovery rate of certified reference materials was 75.0% (US EPA 7196A) and 101.4% (US EPA 7199) by the analytical methods. As the results of performing QA/QC about US EPA 7199, method detection limit (MDL) and limit of quantification (LOQ) were 0.062 mg/kg, 0.196 mg/kg, respectively. The LOQ of US EPA 7199 was lower than that of the current soil official testing method in Korea (0.5 mg/kg). Cr(VI) contents in 23 soil samples were compared by the analytical methods of EPA 7196A and 7199. Cr(VI) was detected in 13 of 23 soil samples by EPA 7196A, while EPA 7199 was not detected in any soil samples. The Cr(VI) content in 23 soil samples by EPA 7196A was not clearly correlated with Cr, Fe, Mn and clay content in the soil samples. However, the contents of Cr(VI) and organic matter of the soil samples had the highest coefficient of determination ($R^2$) of 0.80. In order to evaluate the correlation between the recovery rates of Cr(VI) and organic matter contents in the soil samples, the recovery rates of 5 soil samples added Cr(VI) standard solution were analyzed by the analytical methods. According to the results, the higher the organic matter contents in soil samples, the lower the recovery rates of Cr(VI) by US EPA 7196, while in case of US EPA 7199, the recovery rates were stable regardless of the organic matter contents.

Antioxidant Activities of Stachys sieboldii MIQ. Stalks (초석잠 [Stachys sieboldii MIQ.] 줄기의 항산화 활성)

  • 백홍석;나영수;류병호;송승구
    • KSBB Journal
    • /
    • v.18 no.4
    • /
    • pp.266-271
    • /
    • 2003
  • This study was worked out to investigate the compounds of antioxidant constituents extracted from Stachys Sieboldii MiQ. and their effects on antioxidant activity by DPPH method, ferric thiocyanate method, and nitrite scavenging ability. Solvents such as methanol, hexane, chloroform, ethyl acetate, butanol, and water were used for this purpose. Total concentrations of polyphenols and flavonoids were measured in the methanol fraction. The ethyl acetate fraction showed the strongest activity by DPPH method, ferric thiocyanate method, and nitrite scavenging ability. The ethyl acetate extract was fractionated on a silica gel column using elution solvent (chloroform: methanol: water = 70 : 30 : 5 lower phase) at a flow rate of 1.0 mL/min. UV-VIS spectral data of each fraction showed adsorption maxima in the range of 284~330 nm. Among fractions, the fraction 1 that has λ$\_$max/ (nm) of 284 nm showed the strongest activity by DPPH method. The UV-VIS spectral data of phenolic compounds were known to lie in the range of 210~290 nm and 300~550 nm. Therefore, the results of our study suggested that Stachys sieboldii MIQ. contains phenolic compounds showing natural antioxidant activity.

A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents (대체 세정제의 선정을 위한 세정성 평가방법 연구)

  • Shin, Jin-Ho;Lee, Jae-Hoon;Bae, Jae-Heum;Lee, Min-Jae;Hwang, In-Gook
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • In this study various cleaning evaluation methods were tested and comparatively evaluated to help cleaning industry. In order to select alternative cleaning agents objectively and systematically, various cleaning evaluation methods such as gravimetric, optically simulated electron emission (OSEE), contact angle, and analytical instrument methods were employed for cleaning contaminants such as flux, solder and grease. The analytical instruments used in this work were Fourier transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV-VIS) and high performance liquid chromatography (HPLC). The gravimetric method was able to measure cleaning efficiencies easily and simply, but it was not easy to analyze them precisely because of its limitation in the gravimetric measurement. However, the OSEE technique was able to measure quickly and precisely the clean ability of cleaning agents in comparison with the gravimetric method. The contact angle method was found to be necessary for taking special precaution in its application to the cleaning evaluation due to possible formation of tiny organic film on the substrate surface which might be generated from contaminants and cleaning agents. In case of precision analysis that cannot be done by gravimetric method, fine analytical instruments such as UV-VIS, FTIR and HPLC could be used in analyzing trace amount of flux, solder and grease quantitatively, which were extracted from the surface by special solvents.

Comparison of different colorimetric assays and application of the optimized method for determining the liberated fluoride contents in various tea extracts

  • Le-Thi Anh-Dao;Do Minh-Huy;Nguyen-Ho Thien-Trang;Nguyen Cong-Hau
    • Analytical Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.87-97
    • /
    • 2024
  • The appropriate intake of fluoride (F-) is beneficial to human health; however, the over-consumption can result in various potentially harmful effects. This study compared different colorimetric reagents, i.e., aluminium-xylenol orange (Al-XO), zirconium-xylenol orange (Zr-XO), and zirconium-alizarin red S (Zr-ARS), for fluoride measurements by the UV-Vis, in terms of reaction mechanisms, method sensitivity, and interferences from aluminium and ferric ions. The colorimetric procedures were optimized, and the analytical methods were evaluated. The goodness of linearity (R2 > 0.998) was obtained for all three assays within the concentration range of 1.0-20.0 mg/L fluoride in deionized water, in which the method sensitivity followed the descending order of Zr-XO > Al-XO > Zr-ARS. The Zr-XO was applied for determining the fluoride in different tea extracts in water (90 ℃ and 60-minute-brewing) and black tea demonstrated the highest fluoride content (3.0-3.6 mg/L). The effects of brewing time and temperature on the release of fluoride in the tea extracts were also investigated, indicating these are critical factors for the fluoride extraction. This study highlighted the application potentials of the UV-Vis measurement as a simple, convenient, and cheap analytical approach and discussed different colorimetric reagents used for fluoride determination in tea extracts in the context that the UV-Vis spectrophotometers are commonly equipped in most laboratories.