• Title/Summary/Keyword: UV disinfection system

Search Result 45, Processing Time 0.025 seconds

Hydrothermal Process에 의해 제조된 광촉매를 이용한 Giardia의 살균

  • Yu, Mi-Jin;Ryu, Cheon-Su;Kim, Mun-Seon;Kim, Byeong-U
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.445-446
    • /
    • 2000
  • Disinfection of pathogenic protozoa Giardia has been done by using $TiO_2$ prepared by hydrothermal process. $TiO_2$ suspended in a photoreactor or immobilized on the optical-fiber surface immersed in a photoreactor has been applied with the ultraviolet light. It has been shown that disinfection effect with $TiO_2/UV$ system 2 times as that with only the UV light and disinfection capability of Giardia increased with an increased $TiO_2$ concentration up to 0.1g/L in a $suspended-TiO_2$ reactor.

  • PDF

Formation and Treatment Methods of N-Nitrosodimethylamine (NDMA) in Water and Wastewater (상하수에서 N-Nitrosodimethylamine (NDMA) 발생 및 처리법 비교 분석)

  • Kim, Jongo;Lee, Woo-Bum;Park, Soo-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.1
    • /
    • pp.95-101
    • /
    • 2014
  • Overall studies for the N-nitrosodimethylamine (NDMA) formation and treatment methods were conducted. In this study, occurrence in several countries and emerging treatment technologies of NDMA were generally reviewed. The NDMA formation was dependent on pH, contact time, and molar ratio (monochloramine/dimethylamine). The formation was rapidly increased when the molar ratio was greater than 1. It was likely that monochloramine could be related to stimulate NDMA formation. NDMA concentrations in water supply and wastewater plants after disinfection were approximately 10 ng/L and 100 ng/L, respectively. UV oxidation and adsorption processes are regarded as effective technologies for the NDMA removal. It is suggested that the UV oxidation with proper lamps is applied in water supply system.

Removal of taste and odor causing compounds in drinking water using Pulse UV System (Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구)

  • Sohn, Jin-Sik;Park, Soon-Ho;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.

Evaluation of inactivation kinetics on pathogenic microorganisms by free chlorine/UV hybrid disinfection system (전해 염소수/자외선 결합 시스템을 이용한 병원성 미생물의 불활성화 키네틱스 평가)

  • Seo, Young-Seok;Kim, Aerin;Cho, Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.379-388
    • /
    • 2019
  • Chlorination and UV illumination are being widely applied to inactivate a number of pathogenic microbials in the environment. Here, we evaluated the inactivation efficiency of individual and combined treatments of chlorination and UV under various aqueous conditions. UV dosage was required higher in waste water than in phosphate buffer to achieve the similar disinfecting efficiency. Free chlorine generated by electrolysis of waste water was abundant enough to inactivate microbials. Based on these, hybrid system composed of sequential treatment of electrolysis-mediated chlorination and UV treatment was developed under waste water conditions. Compared to individual treatments, hybrid system inactivated bacteria (i.e., E. coli and S. typhimurium) and viruses (i.e., MS-2 bacteriophage, rotavirus, and norovirus) more efficiently. The hybrid system also mitigated the photo re-pair of UV-driven DNA damages of target bacteria. The combined results suggested the hybrid system would achieve high inactivation efficiency and safety on various pathogenic microbials in wastewater.

A Study on Optimal Design of UV Contactor using an Optical Radiation Model (광학모델을 이용한 자외선 접촉조 최적 설계에 관한 연구)

  • Choi, Younggyun;Kim, Dooil;Kim, Sunghong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.547-552
    • /
    • 2009
  • Because of refractory property of light, the travel path of UV light becomes longer than the straight line and shorter solely in water as UV light passes sequentially through air, quartz and water. Note that water significantly absorbs UV light. Hence, UV intensity shall be estimated to be lower when refraction is neglected than it is considered. Reflection is also critical for the design of UV radiation system. While the reflection at the interface of air and quartz is low enough to ignore, it is too high to be ignored at the interface of quartz and water. Assuming constant power, smaller length to width ratio of UV reactor is beneficial and single-lamp system is preferred to multi-lamps. Under the given cross section, optimal lamp positions could be decided. For example of an elliptical reactor with dual lamps, the optimal lamp locations shall be the 1/3 and 2/3 position of the longer axis.

Analysis of Indicator Microorganism Concentration in the Rice Cultural Plot after Reclaimed Water Irrigation (하수처리수 관개후 벼재배 시험구에서 지표미생물 거동 분석)

  • Jung, Kwang-Wook;Jeon, Ji-Hong;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.112-121
    • /
    • 2004
  • A study was performed to examine the effects of UV-disinfected reclaimed water on microorganism concentration during rice culture. Four treatments were used and each one was triplicated to evaluate the changes of microorganism concentrations: stream water irrigation (STR), biofilter effluent irrigation (BE), UV-disinfected water irrigation with dose of 6 mW ${\cdot}$ s $cm{-2}$ (UV-6), and UV-disinfected water irrigation with dose of 16 mW ${\cdot}$ s $cm{-2}$ (UV-16). The indicator microorganisms of interest were total coliform (TC), fecal coliform (FC), and E. coli. The biofilter effluent from 16-unit apartment sewage treatment plant was used as reclaimed water and flowthrough type UV-disinfection system was used. Concentrations of indicator microorganisms in the treatment plots ranged from $10^2$ to $10^5$ MPN/100 mL during 24 hours after irrigation in May and June, where initial irrigation water for transplanting reparation was biofilter-effluent without UV-disinfection. It implies that initial irrigation using only non-disinfected reclaimed water for puddling in paddy field can be health-concerned because of more chance of farmer's physical contact with elevated concentration of microorganisms. The concentrations of microorganisms varied widely with rainfall, and treatments using UV-disinfected water irrigation showed significantly lower concentrations than others and their levels were within the range of paddy rice field with normal surface water irrigation. The mean concentrations of STR and BE during growing season were in the range of 4 ${\times}\;10^3$ MPN/100 mL for TC, and 2${\times}\;10^3$ MPN/100 mL for FC and E, Coli, While mean concentrations of UV-S and UV-lS were less than 1${\times}\;10^3$ MPN/100 mL for all the indicator microorganisms. Overall, UV-disinfection was thought to be feasible and practical alternative for agricultural reuse of secondary level effluent in Korea.

Effectiveness Analysis on the Application of Ultraviolet and Plasma Treatment Devices for Water Sterilization (용수 살균을 위한 자외선과 플라즈마 처리장치 적용에 따른 효과분석)

  • Kim, Young Jae;Park, Jeon Oh;Lee, Haeng Lim
    • Journal of Marine Life Science
    • /
    • v.4 no.2
    • /
    • pp.86-90
    • /
    • 2019
  • This study aimed to compare the disinfection efficiencies of the ultraviolet and plasma systems, the two systems designed and commercialized to disinfect water in aquaculture, by putting each in a 100 ℓ water tank and concentrating 1.0 ℓ of treated water to check the changes in the number of bacteria in the samples. Each system was operated for 6 hours to culture the typical seawater bacteria in the Marine agar, Thiosulfate citrate bile salts sucrose agar and Salmonella Shigella agar media, respectively, to check the number of bacteria in the media, and the changes in the number of Edwardsiella piscicida in the treated water were checked after the artificial inoculation of E. piscicida in the disinfected seawater. As a result, the two disinfection systems showed the almost similar levels of bacterial reduction efficiency between 99.5% and 99.9%. However, the result of this study showed that, with 100 ℓ of water treated for the same length of time using the two systems, the plasma system turned out to disinfect bacteria in a shorter period of time than the UV system. However, as the changes in the number of bacteria were checked for a short length of time (6 hours) in this study, it was judged that, considering the actual aquaculture environment in which the quality of water significantly changes with feed residues, excretions and coastal contamination, etc., and a lot of biofilms and organic matter exist, the plasma system would be more efficient than the UV system as the former is capable of continuously maintaining a certain level of efficiency than the latter that is limited in terms of efficiency depending on the level of turbidity and the existence of organic matter.

Development of an Ultra-Violet Lamp and a Ballast for Ship's Ballast Water Treatment (선박평형수 처리용 자외선 램프 및 안정기 개발)

  • Cheon, Sang-Gyu;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.675-681
    • /
    • 2011
  • In this paper, we dealt with the design and fabrication of a medium pressure ultra-violet (UV) lamp and a magnetic ballast which are main components for ballast water treatment systems (BWTS). To acquire an optimal discharge condition of UV lamp, electrical and optical characteristics depending on the argon gas volume and the amount of mercury were experimentally analyzed. Rated voltage, current and power consumption of a prototype lamp were 490 [V], 8.6 [A] and 4.0 [kW], respectively. UV intensity of the lamp was 15 [%] higher than that of an equivalent lamp which is used in a BWTS. The magnetic ballast was designed in a UI core type through theoretical analysis and simulation. The open voltage and the rated power consumption of the ballast were 920 [V] and 8.5 [kVA] respectively. The disinfection efficacy which is carried out in a BWTS equipped with the UV lamp and magnetic ballast was over 99.99 [%], and this satisfy the IMO regulations.

Removal of Algogenic Organic Matter in Drinking Water Treatment Process (정수처리공정에서 조류유래 유기물질의 제거)

  • Park, Se-Jin;Cha, Il-Kwon;Yoon, Tai-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • Algae causes not only the eutrophication of lake, but also the deterioration of drinking water process. Especially, algogenic organic matters(AOM) are assumed as disinfection by-products(DBPs) precursors like humic and fulvic acids. In this study, it was investigated the characteristics changes of algogenic organic matter(AOM) by prechlorination and coagulation treatment. Evaluation of enhanced coagulation and applicability of UV oxidation process were also evaluated as the drinking water treatment system for the eutrophicated water source. prechlorination was effective process for algae removal but caused releasing of dissolved organic matter(DOC) into water due to the destruction of algae's cell. In coagulation treatment with Fe(III) coagulant, reaction pH is an important factor for the removal of AOM and triholomathanes(THMs). At pH 5, removal efficiency of DOC and THMs were dramatically improved by 50% and 28%, respectively, in comparison with the conventional coagulation treatment at about pH 7. Photo-Fenton($UV/H_2O_2/Fe^{3+}$) process among the UV oxidations is the most effective system to remove AOM, but its removal efficiency was lower than that of enhanced coagulation treatment at pH 5.

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System - (시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.