• Title/Summary/Keyword: UV System

Search Result 1,279, Processing Time 0.037 seconds

A Comparative Study on Degradation of BTEX Vapor by O3/UV, TiO2/UV, and O3/TiO2/UV System with Operating Conditions (운전조건에 따른 O3/UV, TiO2/UV 및 O3/TiO2/UV 시스템의 BTEX 증기처리에 관한 비교 연구)

  • Kim, Kyoung-Jin;Park, Ok-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2008
  • A multilayer tower-type photoreactor, in which $TiO_2$-coated glass-tubes were installed, was used to measure the vapor-phase BTEX removal efficiencies by ozone oxidation ($O_3$/UV), photocatalytic oxidation ($TiO_2$/UV) and the combination of ozone and photocatalytic oxidation ($O_3/TiO_2$/UV) process, respectively. The experiments were conducted under various relative humidities, temperatures, ozone concentrations, gas flow rates and BTEX concentrations. As a result, the BTEX removal efficiency and the oxidation rate by $O_3/TiO_2$/UV system were highest, compared to $O_3$/UV and $TiO_2$/UV system. The $O_3/TiO_2$/UV system accelerated the low oxidation rate of low-concentration organic compounds and removed organic compounds to a large extent in a fixed volume of reactor in a short time. Therefore, $O_3/TiO_2$/UV system as a superimposed oxidation technology was developed to efficiently and economically treat refractory VOCs. Also, this study demonstrated feasibility of a technology to scale up a photoreactor from lab-scale to pilot-scale, which uses (i) a separated light-source chamber and a light distribution system, (ii) catalyst fixing to glass-tube media, and (iii) unit connection in series and/or parallel. The experimental results from $O_3/TiO_2$/UV system showed that (i) the highest BTEX removal efficiencies were obtained under relative humidity ranging from 50 to 55% and temperature ranging from 40 to $50^{\circ}C$, and (ii) the removal efficiencies linearly increased with ozone dosage and decreased with gas flow rate. When applying Langmuir-Hinshelwood model to $TiO_2$/UV and $O_3/TiO_2$/UV system, reaction rate constant for $O_3/TiO_2$/UV system was larger than that for $TiO_2$/UV system, however, it was found that adsorption constant for $O_3/TiO_2$/UV system was smaller than that for $TiO_2$/UV system due to competitive adsorption between organics and ozone.

Organic Removal Efficiency and Toxicity Evaluation of Persistent Microorganism from Dye Wastewater Treatment using a Photooxidation system (광산화시스템을 이용한 염색폐수의 유기물 처리효율 및 잔류미생물의 독성 평가)

  • Jung, Ho Jun;Rhee, Dong Seok
    • Journal of Industrial Technology
    • /
    • v.29 no.A
    • /
    • pp.83-88
    • /
    • 2009
  • The removal efficiency of organic compounds and the toxicity evaluation of microorganism have been studied in dye wastewater treatment using $UV/TiO_2$ and $UV/H_2O_2$ photooxidation system. Sample waters tested in this work were raw dye wastewater and dye wastewater treated in $UV/TiO_2$ and $UV/H_2O_2$ photooxidation system respectively. Total organic carbon(TOC) removal rate was 50% in $UV/TiO_2$ process and 80% in $UV/H_2O_2$ process. It has been investigated with colony counting agar method and paper disk method whether the type of treatment process has affected the microorganism growth. In the raw wastewater, more than four types of microorganisms have survived. But, little of microorganisms were alive at TOC removal rate of 50% in $UV/TiO_2$ system. In contrast to that, two types of microorganisms were found at TOC removal rate of 80% in $UV/H_2O_2$ system.

  • PDF

A Study on Driving System and Constant Output System for a Low Pressure UV Lamp (저압 UV램프 구동시스템 및 출력안정화 시스템에 관한 연구)

  • Yi, Chin-Woo;No, Jae-Yup
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.19-23
    • /
    • 2005
  • The target of this research is a design of constant and high efficiency driving system for a low pressure UV lamp. An UV lamp system is one of wide range electrical equipments for semiconductor manufacturing and sterilization, etc... It is essential the technique of constant output for high added value device. A design target of driving system for low pressure UV lamp of conversion efficiency is 90[%], UV lamp of output stability within ${\pm}7.5[%]$, and lamp power is over 200[W]. The results meet the target of this study well, and have a benefit of domestic market occupation and enable to export. And if protection circuits were developed, it increases the stability of a electronic ballast for UV lamps.

Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor (비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성)

  • Jeon, Hwa-Bong;Yun, Jung-Won;Kim, Sung-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Feasibility Study of UV Disinfection system of Small Wastewater System for Water Reclamation (용수 재이용을 위한 소규모 하수처리시설의 UV disinfection system)

  • Joung, Kwang-Wook;Yoon, Chun-Gyeong;Ham, Jong-Hwa
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.421-424
    • /
    • 2002
  • Deterministic and probabilistic approaches to the design of ultraviolet (UV) disinfection system for water reclamation are reviewed and discussed. The high inactivation of TC, FC and E. coli by UV disinfection was demonstrated and the inactivations of TC, FC and E. coli were 97%, 98% and 99%, respectively. Within the range of 0.3-4.5mWs/cm, the effect of UV does on the inactivation ratio was not observed. However, in the highest wattage of UV lamp, 39W, the inactivation ratio of TC, FC and E. coli was 100%, regardless of the UV does so the UV density was more effective on inactivation ratio of TC, FC and E. coli rather than UV does. Under the 0.4 mWs/cm and 16W of UV lamp, the effect of dissolved organic matter and turbidity on the inactivations of TC, FC and E. coli could not be observed in this study within the range of 0-60mg/L and 0-40 NTU respectively.

  • PDF

Removal of taste and odor causing compounds in drinking water using Pulse UV System (Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구)

  • Sohn, Jin-Sik;Park, Soon-Ho;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.

Removal of Non-biodegradable Organic Contaminants in Wastewater from crude oil reserve base Using Pulse UV System (Pulse UV 장치를 이용한 원유비축시설 발생폐수의 난분해성 유기오염물질 제거)

  • Sohn, Jin-Sik;Park, Soon-Ho;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.861-867
    • /
    • 2011
  • Wastewater from crude oil reserve base usually contains large amount of non-biodegradable contaminants. The conventional wastewater treatment progress can hardly meet the regulation of wastewater effluent quality. This study investigated the removal of non-biodegradable organic contaminants in wastewater from crude oil reserve base using a pulse UV treatment. The modified process incorporating pulse UV process was set up to treat the wastewater from crude oil reserve base. The treatment process is composed with coagulation and flocculation, micro-bubble flotation, sand filter, pulse UV system, and GAC filter. The results show CODMn was effectively removed by the process with pulse UV system and it can meet the wastewater effluent regulation. The single effect of pulse UV process in CODMn removal was not significant(9~15% based on sand filtered effluent), however with the subsequent activated carbon filter the removal ratio CODMn was increased up to 28% compared to the process without pulse UV syetem.

Development of UV curable polymer and curing characteristics estimation for UV nanoimprint (UV 나노임프린트를 위한 UV 경화성 수지 개발 및 경화 특성 평가)

  • 이진우;이승재;이응숙;정준호;조동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1220-1223
    • /
    • 2003
  • The UV nanoimprint technology uses the UV light as the energy source. Because the imprint process is carried out in room temperature and low pressure, this technology has its own merits compared to the thermal nanoimprint. However, in UV nanoimprint technology, a resin which has low viscosity is essential for the improvement of accuracy. In this research, a resin (named as IMS01) which has relatively low viscosity was developed. And a measurement system was developed in order to measure the degree of cure of the resin. The measurement system which is composed of FT-IR, UV light source and optical guide can measure the degree of cure in real time. From the experimental results, it was found that the IMS01 is cured more rapidly than existing resin (PAK01).

  • PDF