• Title/Summary/Keyword: US3

Search Result 4,828, Processing Time 0.031 seconds

LEED for Homes Rating System and Resident Satisfaction with LEED-Certified Homes - Focusing on the US Cases - (LEED for Homes의 인증제도 특성 및 인증 후 거주자 만족도 조사 - 미국 사례를 중심으로 -)

  • Kim, Suk-Kyung;Lee, Eunsil
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.25-34
    • /
    • 2014
  • The major purposes of this study were to analyze main features of US Green Building Council's LEED for Homes rating system and examine residents' satisfaction on their LEED-certified homes and neighborhoods. The first part of this article shows the structure and features of the LEED for Homes rating system and the process to obtain credits of this rating system. The investigation to assess residents' satisfaction targeted LEED certified home residents in Midwest in the United State. The satisfaction was assessed in relation to socio-demographic and housing characteristics. To collect data, a quantitative survey was administered to the residents of LEED-certified homes in Midwest in the US. A total of 605 surveys was sent out and 235 were collected, yielding a 38.8% response rate. Findings revealed that LEED-certified home residents were highly satisfied with their homes and neighborhood although neighborhood satisfaction was lower than housing satisfaction. Residents' income and education were the significant socio-demographic factors that show significant relationships with housing satisfaction. Residents' home ownership, length of residence, housing types were significant housing characteristics on their satisfaction while the levels of LEED certifications (i.e., certified, silver, gold, and platinum) were not significantly related to housing satisfaction. The findings of this study suggest the importance of developing effective strategies for those who are less educated, lower income classes, renters, or multi-attached housing residents for more successful development of LEED-certified homes in the future.

A New Record of Epicoccum draconis Isolated from the Soil in Korea

  • Ayim, Benjamin Yaw;Das, Kallol;Cho, Young-Je;Lee, Seung-Yeol;Jung, Hee-Young
    • The Korean Journal of Mycology
    • /
    • v.48 no.1
    • /
    • pp.39-45
    • /
    • 2020
  • A fungal isolate US-18-11 was isolated from the soil in Uiseong, Korea. The mycelium growth measured after 7 days of incubation at 22℃ on malt extract agar (MEA) and oatmeal agar (OA) media was 42-43 mm and 41-44 mm in diameter, respectively. The fungal colony formed white to dull green aerial mycelia that were floccose with regular margins and olivaceous black with leaden gray patches on the reverse side. The conidia were hyaline to brown in color, ellipsoidal to ovoid, guttulate, abundant, globose, solitary, or confluent measuring 3.2-7.2×1.1-2.3 ㎛. A BLAST search of the large subunit (LSU), internal transcribed spacer (ITS) region, second largest subunit of DNA-directed RNA polymerase II (RPB2) and β-tubulin (TUB2) gene sequences revealed that the isolate US-18-11 has similarities of 99, 100, 97, and 99% with those of Epicoccum draconis CBS 186.83, respectively. A neighbor-joining phylogenetic tree constructed based on the concatenated dataset of above-mentioned sequences showed that isolate US-18-11 clustered with Epicoccum draconis CBS 186.83 in the same clade. Based on the results of morphological, cultural, and phylogenetic analysis, the isolate US-18-11 was identical to the previously described E. draconis CBS 186.83. To our knowledge, this is the first report of E. draconis in Korea.

Ultrasonographic Evaluation of Renal Cortex and Outer Medulla Thickness in Dogs with Chronic Kidney Disease

  • Lee, Siheon;Hong, Sungkyun;Kim, Hyejin;Oh, Dayoung;Kim, Seungji;Choen, Sangkyung;Choi, Mincheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.34 no.3
    • /
    • pp.208-212
    • /
    • 2017
  • This study was performed to retrospectively pursue any correlation between renal cortex thickness (RCT), outer medulla thickness (OMT) on ultrasonography (US) and chronic kidney disease (CKD) with International Renal Interest Society (IRIS) stage. Medical records and US findings of the dogs diagnosed CKD were reviewed for comparing to those of the clinically healthy dogs from March. 2015 through June. 2016. To evaluate the correlation about normal and CKD patients, RCT and the OMT were measured on US images. RCT and OMT were adjusted by dividing body surface area for standardization (RCTS, OMTS). Also the ratio of RCT/OMT were calculated and these indices were evaluated to investigate any tendency between 5 groups (normal and 4 IRIS stages) using Jonckheere-Terpstra trend test (J-T test). The RCTS showed a declining tendency (p < 0.02) and the OMTS showed an inclining tendency from normal through each IRIS stage (p < 0.01). The RCT/OMT showed also declining tendency (p < 0.01). Although the gold standard for renal function including GFR is lack, it is thought that differentiation between normal and CKD patients could be possible on US measurement of renal cortex and outer medulla thickness, which could be an alternative index for kidney function in diagnostic imaging.

A Study on the Korean Interest Rate Spread Prediction Model Using the US Interest Rate Spread : SVR-Ensemble (RNN, LSTM, GRU) Model based (미국 금리 스프레드를 이용한 한국 금리 스프레드 예측 모델에 관한 연구 : SVR-앙상블(RNN, LSTM, GRU) 모델 기반)

  • Jeong, Sun-Ho;Kim, Young-Hoo;Song, Myung-Jin;Chung, Yun-Jae;Ko, Sung-Seok
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.3
    • /
    • pp.1-9
    • /
    • 2020
  • Interest rate spreads indicate the conditions of the economy and serve as an indicator of the recession. The purpose of this study is to predict Korea's interest rate spreads using US data with long-term continuity. To this end, 27 US economic data were used, and the entire data was reduced to 5 dimensions through principal component analysis to build a dataset necessary for prediction. In the prediction model of this study, three RNN models (BasicRNN, LSTM, and GRU) predict the US interest rate spread and use the predicted results in the SVR ensemble model to predict the Korean interest rate spread. The SVR ensemble model predicted Korea's interest rate spread as RMSE 0.0658, which showed more accurate predictive power than the general ensemble model predicted as RMSE 0.0905, and showed excellent performance in terms of tendency to respond to fluctuations. In addition, improved prediction performance was confirmed through period division according to policy changes. This study presented a new way to predict interest rates and yielded better results. We predict that if you use refined data that represents the global economic situation through follow-up studies, you will be able to show higher interest rate predictions and predict economic conditions in Korea as well as other countries.

Flour Characteristics and End-Use Quality of Korean Wheats with 1Dx2.2+1Dy12 Subunits in High Molecular Weight Glutenin

  • Park, Chul-Soo;Baik, Byung-Kee;Kang, Moon-Seok;Park, Jong-Chul;Park, Jae-Gun;Yu, Chang-Yeon;Choung, Myoung-Gun;Lim, Jung-Dae
    • Preventive Nutrition and Food Science
    • /
    • v.11 no.3
    • /
    • pp.243-252
    • /
    • 2006
  • White salted noodles and pan bread were prepared from Korean wheats with 1Dx2.2+1Dy12 subunits in high molecular weight glutenin subunits (HMW-GS) to evaluate the suitability for end-use products through the comparison with US wheats with various classes and commercial wheat flours. Korean wheat flours with 1Dx2.2+1Dy12 subunits showed higher SDS sedimentation volume than US wheat flours with similar protein content. Compared to wheat flours with similar protein content and SDS sedimentation volume, water absorption percent of Korean wheat flours using a mixograph was higher than that of US wheat flours, but similar to commercial wheat flours. Mixograph mixing time was similar to hard wheat flours and commercial noodle flours. Optimum water absorption percent of noodle dough from Korean wheat flours was higher than that of US wheat flours. Noodle sheets from Korean wheat flours with 1Dx2.2+ 1Dy12 subunits showed lower L values, higher a values and similar b values compared to commercial noodle flours. Hardness of cooked noodles from Korean wheat flours 1Dx2.2+1Dy12 subunits correlated positively with protein content, NIRS hardness, mixograph water absorption and gluten yield of flours. Korean wheat flours with 1Dx2.2+1Dy12 subunits showed lower loaf volume and harder crumb firmness than hard wheat flours and commercial bread wheat flours in spite of similar protein quantity and quality to hard wheat flours.

Importance of Relative Comparison of Capsular Widths on the Affected and Non-Affected Sides of Temporomandibular Joint Arthralgia Patients: An Ultrasonography Study

  • Hee-Won Kim;Yong-Woo Ahn;Sung-Hee Jeong;Soo-Min Ok;Hye-Mi Jeon;Hye-Min Ju
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.3
    • /
    • pp.106-111
    • /
    • 2023
  • Purpose: In this study, we evaluate the potential of the relative ratio of capsular width (RCW) between the affected side (Aff) and non-affected side (Non-aff) in patients with temporomandibular joint (TMJ) arthralgia. We assessed whether RCW may hold greater diagnostic significance than the objective capsular width (CW) reported in previous studies when diagnosing arthralgia using ultrasonography (US). Methods: Forty-nine patients were assessed using US, excluding four patients with bilateral arthralgia. The patients were divided into two groups: 40 with unilateral arthralgia (UA), and nine without arthralgia (NA). We measured CW and masseter muscle thickness using US. Moreover, we employed RCW to analyze the variances between the groups. The numerical rating scale (NRS) and RCW were compared before and after dexamethasone injection in 10 patients who underwent follow-up evaluations. Results: Within the UA group, CW on the Aff was found to be significantly larger compared to the Non-aff (p<0.001). Additionally, RCW in the UA group was greater than that in the NA group (p<0.01). Furthermore, after dexamethasone injection, a reduction in the NRS and RCW values was observed in the 10 patients who were followed up. Conclusions: While previous studies have suggested a link between arthralgia and TMJ effusion, making CW a possible indirect diagnostic indicator for arthralgia, our findings propose that RCW could hold more diagnostic value than objective CW. However, additional studies are required to standardize the protocols for interpreting US results and determining the cutoff value of RCW in diagnosing TMJ arthralgia.