• Title/Summary/Keyword: UPS (uninterruptible power supply)

Search Result 173, Processing Time 0.034 seconds

Development of 3kW Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발)

  • Yang, Seok-Hyun;Kim, Min-Jae;Choi, Se-Wan;Cho, Jun-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.

Voltage Controller Using Feedforward of Single-Phase Inverter for Uninterruptible Power Supply (무정전전원장치용 단상인버터의 전향보상을 이용한 전압 제어기)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.253-254
    • /
    • 2014
  • 본 논문에서는 무정전전원장치(UPS : Uninterruptible Power Supply 이하 UPS)에서 사용되는 단상인버터의 전압 제어기의 낮은 대역폭으로 인하여 발생될 수 있는 전압 위상 지연 문제를 해결한다. 제안하는 방법은 전압 명령에 대한 전향보상을 이용한 새로운 전압 제어기를 제안하고 이를 MATLAB Simulink를 사용한 시뮬레이션을 통하여 효과를 입증하였다.

  • PDF

Network Based UPS Remote Control System Using SNMP (네트워크 환경에서의 무정전전원장치용 원격제어 시스템)

  • 최소영
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.744-747
    • /
    • 2000
  • This paper aims at developing remote control system to control and monitor distribute various devices through internet or information communication network. So far for managing UPS(Uninterruptible Power Supply) serial communication system has been used. This paper proposes managing method of UPS monitoring using SNMP. It consists of SNMP agent network board SNMP manager PC software serial communication software and UPS. The proposed method can be applied to various devices with communication network remotely.

  • PDF

Investigation of Dynamic Characteristcs Uninterruptible Power Supply System (UPS) Using Shaking Table Tests (무정전전원장치(UPS)의 진동대 실험 및 동적특성 분석)

  • Lee, Seung-Jae;Kim, Joo-Young;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.129-136
    • /
    • 2019
  • Non-structural elements are vulnerable to earthquake ground motion. In this study, an experimental study for the electrical non-structural element was performed using tri-axial shaking table tests. A 100kVA UPS(Uninterruptible Power Supply system) was used as the test specimen. The test specimen was anchored to the concrete slab using the conventional installation detail. The input acceleration were generated in accordance with ICC-ES AC156 code. Scale factors of the input acceleration with respect to the required response spectrum defined in ICC-ES AC156 were from 25% to 600%. Based on the test results, damage and dynamic characteristics of UPS were evaluated and analyzed including natural frequency, damping ratio, acceleration time history response, dynamic amplification factor and relative displacement.

Comparison of Current Control Method for Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 전류 제어기법 비교)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • This paper describes the performance comparison results for current controller of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS(Uninterruptible Power Supply). A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of current controller design and comparison of current control method has not been known after the converter circuit was proposed. For the performance comparison of current control, single-phase 3 kVA double-conversion UPS was tested. The performance of PI and PR current controller is experimentally confirmed with followings - input current reference tracking, input power factor correction and input current THD suppression.

Single-Phase Double-Conversion UPS with Energy Storage System (ESS 기능을 갖는 단상 이중변환 UPS)

  • Lim, Seung-Beom;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.137-138
    • /
    • 2013
  • This paper proposes the single-phase double-conversion UPS(Uninterruptible Power Supply) with ESS(Energy Storage System). The Proposed system is operating in three modes, which are normal mode, battery mode, and bypass mode. Not only in black-out but also in peak load times, the system is operating in battery mode which is using the stored energy of the battery to manage the power effectively. The validity of proposed system could be verified by simulations and experiments.

  • PDF

A study of transient characteristics during the transfer of the source of electric power in UPS (UPS에서 전원 절체시 과도특성에 관한 연구)

  • Lee, Young-Soo;Lee, Kan-Woon;Cha, Jae-Man
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.88-90
    • /
    • 2005
  • There are a lot of troubles during the transfer of the source of electric power in UPS (uninterruptible power supply system) which is indispensable to the industrial equipments. They cause blackout accidents, resulting in a great economic loss. After measuring and analyzing the transient phenomena happening during the transfer, this paper presents the solution of the troubles. The solution can be used as a basic material for maintenance and it can minimize the troubles occurring in UPS and enhance the reliability of it.

  • PDF

A Study on the Uninterruptible Power Supply(UPS) System with Superconducting, Magnet Energy Storage(SMES) (초전도 에너지 저장장치를 이용한 무정전 전원장치 시스템의 연구)

  • Kim, Tae-Wan;Ji, Ho-Chul;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1919-1923
    • /
    • 1997
  • Superconducting magnet energy storage(SMES) offers lower loss and more capacity than other energy storage systems. This paper deals with a configuration and a control method of uninterruptible power supply(UPS) with SMES, Proposed system is constituted of three partsinverter, dc chopper and superconducting coil. The control system is implemented with a general-purpose DSP, TMS320C31. The results of simulation and experiment with a 10kVA prototype show the validity of the system configuration and the control method.

  • PDF

Real Time Digital Control of PWM Inverter for Uninterruptible Power Supply(UPS) application (무정전 전원공급장치 적용을 위한 PWM 인버터의 Digital 실시간 제어)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.56-60
    • /
    • 1999
  • This paper presents the high performance real time control system of PWM inverter for uninterruptible power supply(UPS). This system is based on a digital control scheme which calculates the pulse widths of the inverter switches for the next sampling time in digital signal processor(DSP). A PI compensator is used to eliminate the voltage error caused by the difference between the actual values of LC filter and those designed. Double regulation loops which are the inner current loop and the outer voltage loop are used to make the transient response time reduce in load disturbance and nonlinear load. This method makes it possible to obtain better response in comparison to conventional digital control system. The proposed scheme provides good performance such as stable operation, low THD of the output voltage, and good dynamic response for load variations and nonlinear load.

  • PDF

Reduction of Current Harmonic Occurred form between Uninterruptible Powers Supply and Rectifier Load (정류기 부하와 무정전전원장치 사이에 발생되는 Current Harmonic 저감)

  • 곽철훈;반한식;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.41-44
    • /
    • 1999
  • The main purpose of the UPS is to supply independent and stable power to connected equipment. In installing and operating the UPS system, songle module, three phase UPS in more benefit than multi module, songle phase UPS in the point of volume and cost. However, when supplying Rectifier with output power form three phase UPS, by connecting auto-transformer, occurred harmonic and ripple current makes output filter damaged and leads to nonlinear current coasted by unbalance load. Therefor, in this paper the aim of concentring compound-wound transformer and harmonic filter is supplying liner current by reducing harmonic and ripple current and improving unbalance in voltage and distortion in current wave.

  • PDF