• Title/Summary/Keyword: UPS

Search Result 1,670, Processing Time 0.032 seconds

Improvement of Naval Combat System UPS under Abnormal Transients (비정상 과도상태에서의 해군 전투체계 UPS 개선)

  • Kim, Sung-Who;Choi, Han-Go
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.97-103
    • /
    • 2018
  • This paper addresses an improved naval combat UPS(Uninterruptable Power Supply) system under abnormal transients. Previously, thermistor and varistor elements were used to cope with transient overvoltage and overcurrent, however the UPS was frequently unavailable because it was vulnerable to abnormal transient voltage generated during system operation. In order to overcome this problem and protect UPS system, this paper proposes an input power cut-off circuit that detects the initial input power and abnormal transient voltage generated during operation, improvement of power control sequence, and a method to prevent malfunction of an inverter and CPU. The UPS system implementing the proposed method was simulated by input power variable test using programmable AC/DC generator, and finally validated its reliability and stability through field tests by mounting on multifunctional console of naval combat system.

Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply (USP의 신뢰성 향상을 위한 독립제어 고속절환장치)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.278-286
    • /
    • 2008
  • This paper investigates the fault generation type and the cause of output interruptionsin bulky with $30^{\sim}500[KVA]$ double conversion UPS, and proposes the fault detection method to improve the reliability of power supply used in the critical load in industry. Identifies its existing way of detecting a quality of inverter output it to bypass when exceeds its expectation. Under a UPS managing system, when an inner (Power device, Controller, CPU) fault occurs it disrupts the power supply and these occurrences has been verified by the results of experiments and application results. To overcome these problems, the proposed method constructs independently a fault-detection, a bypass-control device and a triple power supply apart from the conventional UPS operation. Also the detection point is changed to the preceding of a circuit breaker, a reference of fault detection is modified to avoid any clash and the breaking equipment is attached to intercept a spread of accident. As a result of applications of these developed systems to 242 UPS which was installed purposefully to the communication power supply, the service errors has not occurred in the UPS for two years since 2006.

ENDODONTIC FALRE-UPS INCIDENCE AND RELATED FACTORS (근관치료시 flare-up 발생빈도와 관련요소에 관한 연구)

  • Jung, Hye-Young;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.102-111
    • /
    • 2005
  • The purpose of this study was to assess the incidence of flare-ups among patients who received endodontic treatment and to examine the correlation with pre-operative and operative variables. Analysis was in two aspects (a) overall incidence of flare-ups as expressed by a percentage of all patients visits and (b) percentage of flare-ups that occurred as related to various factors suck as patient demo-graphics, diagnosis, and treatment procedures. 1. From the 840 teeth which were examined in this study, the total number of flare-ups was 13. 2. As to gender of patients, there was no significant difference in flare-ups. 3. As to tooth groups, there was no significant difference in flare-ups. 4. In the teeth with pre-operative symptom, there was a statistically significant higher incidence of flare-ups than the teeth without it. 5. In the teeth with apical periodontitis, there was a statistically significant higher incidence of flare-ups. 6. As to pulp and periapical status. non-vital teeth had a higher incidence as compared with vital teeth, irreversible pulpitis. 7. Multi-visit treatment resulted in the higher incidence of flare-ups than one visit treatment. 8. Re-treatment procedures had a statistically significant higher incidence of flare-ups than root canal treatment. In this study, overall percentages of flare-ups was $1.55\%$. It showed a statistically significant higher incidence related to pre-operative symptom, apical periodontitis, and re-treatment. There was no significant difference in flare-ups related to gender, tooth groups, and fistula.

Low Cost and High Performance Single Phase UPS Using a Single-Loop Robust Voltage Controller

  • Ji, Jun-Keun;Ku, Dae-Kwan;Lim, Seung-Beom
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.695-701
    • /
    • 2015
  • Uninterruptible Power Supplies (UPSs) can be largely divided into the passive-standby, line-interactive and double-conversion methods. This paper proposes a double-conversion UPS with a low cost and high performance. This single phase UPS uses a single-loop robust voltage controller and 1-switch voltage doubler strategy PFC. The proposed UPS is composed of a single phase PFC, a half-bridge inverter, a battery charger and a battery discharger. Finally, the validity of proposed UPS was verified by various experimental tests.

Gird-interactive Current Controlled Voltage Source Inverter System with UPS (UPS를 고려한 계통연계 전류제어형 전압원 인버터)

  • Ko, Sung-Hun;Lim, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.

The development of an UPS using PWM Converter and Resonant Inverter (PWM 콘버터와 공진형 인버터를 채용한 UPS 개발)

  • Min, B.G.;Ryu, S.P.;Baek, B.S.;Kim, Y.P.;Shin, H.J.;Kim, D.U.;Yoo, D.W.;Baek, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.550-552
    • /
    • 1996
  • In order to develop a noble Uninterruptible Power Supply(UPS), we designed and manufactured the UPS using the PWM converter and the Resonant DC Link Inverter. This paper describes the power circuits, the key techniques, the control and monitoring unit of the developed UPS. Finally, using the UPS we verified the superiority through the type test.

  • PDF

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun;Kim, Jang-Hwan;Sul, Seung-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

Wireless Parallel Operation of a Three-phase Modular UPS Inverter using Resistive Droop Control (저항성 수하 제어를 적용한 3상 모듈형 UPS 인버터의 비통신선 방식 병렬 운전)

  • Kim, Seon-Tae;Ji, Jun-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1672-1681
    • /
    • 2016
  • This paper proposes a wireless parallel operation method of three-phase modular UPS inverter using resistive droop control. Furthermore, it applies a virtual resistor to droop control so that the output impedance of UPS inverter gets closer to resistive. It makes resistive droop control effective. The simulation using PSIM was performed in order to verify the validity of proposed algorithm. After consisting two-parallel system with three-phase modular UPS inverter, the experiment according to resistive load was conducted. It demonstrated the performance of current sharing and power sharing.

Flywheel Energy Storage UPS with Voltage Compensation (플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS)

  • Lee K .S.;Kim J. W.;Byeon W. Y.;Nho E. C.;Kim I. D.;Chun T. W.;Kim H. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.592-596
    • /
    • 2004
  • This paper deals with the operation of a flywheel energy storage UPS. The ups has good features such as long life-time, improved efficiency, no environment problems, reduced size and space, and low maintenance cost compared with the conventional UPS using battery. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. Especially, the tracking characteristic of the disturbed phase of the source voltage after outage is analysed. The usefulness of the operation is proved through simulations.

  • PDF

How Should Techno Parks Innovate to Support Start-ups and Small and Medium-Sized Enterprises Effectively in the Era of the Fourth Industrial Revolution?

  • Cho, Inje;Lee, Eung-Hyun;Cho, Hoonje
    • World Technopolis Review
    • /
    • v.6 no.1
    • /
    • pp.4.1-4.15
    • /
    • 2017
  • In 1995, the Republic of Korea started to establish Techno Park (TP) in order to develop the regional industry while promoting the balanced development of the land. By 2008, 18TPs were established nationwide and have become cradles for developing local industries. And recently evolved forms of TP such as Daedeok Techno Valley and Pangyo Techno Valley emerged. In addition, 19 Centers for Creative Economy and Innovation (CCEI) were established nationwide and Tech-Incubator Program for start-ups (TIPS) was introduced to support and mentor start-ups. TPs in Korea become bureaucratic in course of time, and the new trial of innovation of TP is needed. In Korea, professional TIPS-accelerators mentoring and investing start-ups have a history of only five years. But they support and mentor start-ups efficiently, and have obtained good results. In this paper, we propose that TP attract TIPS-accelerators actively and collaborate with each other to support and mentor start-ups and SMEs effectively.