• 제목/요약/키워드: UPFC

검색결과 158건 처리시간 0.044초

저주파 진동 해석을 위한 UPFC의 동적 시뮬레이션 알고리즘에 관한 연구 (A Study on the UPFC Dynamic Simulation Algorithm for Low Frequency Oscillation Studies)

  • 손광명
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.502-508
    • /
    • 2000
  • This paper presents a dynamic simulation algorithm for studying the effect of United Power Flow Controller(UPFC) on the low frequency power system oscillations and transient stability studies. The proposed algorithm is a Newton-type one and uses current injection type UPFC model, which gives a fast convergence characteristics. The algorithm is applied to studying inter-area power oscillation damping enhancement of a sample two-area power system both in time domain and frequency domain. The case study results show that the proposed algorithm is very efficient and UPFC is very effective and robust against operating point change.

  • PDF

다기 전력 시스템 동적 안정도 향상을 위한 UPFC 제어기에 관한 연구 (a study on UPFC Controller for enhancing the Multi-machine Power System Dynamic Stability)

  • 김종현;정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.93-95
    • /
    • 2002
  • This paper presents the design of a Unified Power Flow Controller(UPFC) for enhancing the small signal voltage stability in the multi-machine power systems. Recently a lot of attention has been paid to the subject of dynamic stability. The paper deals with analysis of eigenvalue sensitivities with respect to parameters of UPFC Controller. The series branch of the UPFC is designed to damp the power oscillation during transients, while the shunt branch aims at maintaining the bus voltage. Comprehensive time-domain simulation studies using Pss/E show that the proposed robost UPFC controller can enhance the small signal stability efficiently in spite of the variations of power system operating conditions.

  • PDF

한전계통의 전압안정도 향상 및 과부하 해소를 위한 80MVA UPFC(Unified Power Flow Controller) 설치 (Installation of 80MVA UPFC(Unified Power Flow Controller) for improving voltage stability and reducing heavy load in KEPCO power systems)

  • 오관일;장병훈;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.262-265
    • /
    • 2001
  • 최근 전력계통의 과부하, 전압안정도 등의 문제에 대한 해결책으로 FACTS (Flexible AC Transmission Systems)가 대두되고 있다. FACTS 설비에는 TCSC (Thyristor-Controlled Series Capacitor), SSSC (Static Synchronous Series Capacitor)와 같은 직렬 기기와 SVC(Static Var Compensator), STATCOM(STATic COMpensator) 와 같은 병렬기기 그리고, 본 논문에서 다루는 UPFC와 같은 직 병렬기기로 나누어진다. UPFC는 SSSC와 STATCOM을 결합한 형태로 유 무효전력을 동시에 보상할 수 있는 FACTS 기기이다. 본 논문에서는 한전 계통의 전압안정도 향상과 과부하 해소를 위해 강진S/S에 설치예정인 80MVA UPFC의 하드웨어 특성과 주변계통의 특성을 소개하고, UPFC와 한전 계통의 연계방안과 시험방안을 설명한다.

  • PDF

UPFC Performance Control in Distribution Networks for DG Sources in the Islanding

  • Fandawi, Ahmed;Nazarpour, Daryoosh
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.303-309
    • /
    • 2017
  • The flexible AC transmission system (FACTS) provides a new advanced technology solution to improve the flexibility, controllability, and stability of a power system. The unified power flow controller (UPFC) is outstanding for regulating power flow in the FACTS; it can control the real power, reactive power, and node voltage of distribution networks. This paper investigates the performance of the UPFC for power flow control with a series of step changes in rapid succession in a power system steady state and the response of the UPFC to distribution network faults and islanding mode. Simulation was carried out using the MATLAB's simulink sim power systems toolbox. The results, which were carried out on a 5-bus test system and a 4-bus multi-machine electric power system, show clearly the effectiveness and viability of UPFC in rapid response and independent control of the real and reactive power flows and oscillation damping [6].

UPFC 이상변압기 모델을 사용한 유연송전장치 일차민감도 해석 (First-Order Sensitivities for FACTS Devices using UPFC Ideal Transformer Model)

  • Thomas W. Gedra;Seung-Won An
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.837-846
    • /
    • 2004
  • This paper presents a screening technique for greatly reducing the computation involved in determining the optimal location and types of Flexible AC Transmission System (FACTS) devices in a large power system. The first-order sensitivities of the generation cost for various FACTS devices are derived. This technique requires solving only one optimal power flow (OPF) to obtain sensitivities with respect to FACTS device control variables for every transmission line To implement a sensitivity-based screening technique, we used a new UPFC model, which consists of an ideal transformer with a complex turns ratio and a variable shunt admittance. A S-bus system based on the IEEE 14-bus system was used to illustrate the technique.

강진 UPFC 고장실적 분석 (The analysis of Kangjin UPFC faults)

  • 김수열;이원교;장병훈;전영수;이세일;배정현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.450-452
    • /
    • 2006
  • 한전 전력연구원은 1990년대부터 FACTS(유연송전시스템 : Flexible AC Transmission System)을 연구해 온 이래 80MVA UPFC(종합조류제어기 : Unified Power Flow Controller)를 2003. 5월 신강진전력소관내 강진변전소에 준공하였다. 효성과 지멘스의 기술제휴를 통해 개발된 강진변전소 UPFC를 통해 FACTS 엔지니어링, 제어 알고리즘 및 유지보수 기술이 확보되었다. 초창기 안정화운전 기간동안 제어핵심기술과 일부예비품의 미확보가 가용율(Availability)에 큰 영향을 미쳤으나, 현재 강진 UPFC는 안정적으로 운전되고 있다. 본 논문에서는 그 동안의 강진 UPFC의 고장내용을 종합분석하고, 가용율을 정리하였다.

  • PDF

D-UPFC Application as the Series Power Device in the Massive Roof-top PVs and Domestic Loads

  • Lee, Kyungsoo
    • Current Photovoltaic Research
    • /
    • 제4권4호
    • /
    • pp.131-139
    • /
    • 2016
  • This paper shows the series power device in the massive roof-top PVs and domestic loads. D-UPFC as the series power device controls the distribution voltage during voltage rise (or fall) condition. D-UPFC consists of the bi-directional ac-ac converter and the transformer. In order to verify the D-UPFC voltage control, the distribution model is used in the case study. D-UPFC enables the voltage control in the distribution voltage range. Dynamic voltage control from voltage rise and voltage fall conditions is performed. Scaled-down experimental test of the D-UPFC is verified the voltage control and it is well performed without high voltage spikes in the inductive load.

EMTDC를 이용한 UPFC의 스위칭 레벨 시뮬레이션 모형 개발 (Development of the UPFC Switching Level Simulation Model using EMTDC)

  • 한병문;백승택;문승일;이학성;유일도;추진부;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.15-19
    • /
    • 2001
  • 본 논문에서는 한전에서 강진변전소에 파이롯플랜트로 설치 중에 있는 80MVA 용량의 3-레벨 12-펄스형 UPFC의 EMTDC 모델링에 대해 기술하고 있다. UPFC의 EMTDC를 이용한 시뮬레이션 모형은 그 목적에 따라 상세 정도가 상이한 다양한 형태가 존재하나 본 연구에서는 향후 RTDS에 연계하여 전력계통과의 동적 성능 평가에 적용 가능하도록 인버터를 스위칭 레벨 다중펄스 전압원으로 모델링하였다. 개발된 시뮬레이션모형의 타당성은 정현파 이상진원을 사용한 시뮬레이션 분석결과와 비교검토 하여 검증하였다. 개발된 시뮬레이션모형은 UPFC의 성능분석과 전력계통과의 동적응동 해석에 유용하게 활용 가능하고 또한 UPFC 운전자에게 동작특성과 초보적인 운전특성을 교육하는데도 활용가능 할 것으로 보인다.

  • PDF

UPFC가 연계 된 강진-장흥 송전선로 보호용 거리계전기의 동작특성에 관한 연구 (A Study on Operation Zone of Adaptive Distance Relay on Transmission Line Connected UPFC Between Kangjin and Jangheung)

  • 이승혁;정창호;김진오;정현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.305-307
    • /
    • 2003
  • This paper presents an apparent impedance calculation procedure for distance relaying of transmission line involving FACTS (Flexible AC Transmission System) devices, particularly the UPFC (Unified Power Flow Controller), between Kangjin and Jangheung in Korea. With the changes of UPFC's parameters, the measurement and protective range (trip boundaries) of the adaptive distance relay can also be changed. So, it is the most important part in the field of system protection to analyze the operating characteristic of relaying system. The presence of UPFC significantly affects the trip boundaries which are also adversely affected by fault resistance combined with remote end infeed. This paper presents the apparent impedance calculations and the distance relay setting characteristics for faults involving the UPFC in the KEPCO system.

  • PDF

강진 UPFC 운전 경험 (The operation experience of Kangjin UPFC)

  • 김수열;윤종수;장병훈;전영수;백두현;이세일
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.71-73
    • /
    • 2005
  • 한국전력공사에서는 전압원 인버터형 FACTS 기기인 UPFC를 전남 강진군 강진변전소에 설치(2003. 5. 23준공) 운전하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병렬인버터, 40MVA 직럴인버터로 구성되어 총 80MVA 용량이다. 준공이후 2년여에 걸친 운전으로, 강진UPFC의 고장정지는 현저히 줄었다. 본 논문에서는 강진 UPFC의 주요 이벤트, 고장해소 및 설비의 신뢰성 향상을 위한 대응 조치들에 대해 정리하였다.

  • PDF