• 제목/요약/키워드: UHV

검색결과 207건 처리시간 0.038초

극간절연회복성능 향상을 위한 초고압GCB의 노즐형상설계 (Design of Nozzle Shape for UHV GCB to Improve the Dielectric Recovery Characteristics between Electrodes)

  • 송기동;박경엽;신영준;권기영;송원표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.479-481
    • /
    • 1995
  • This paper presents a method witch tan improve the dielectric recovery characteristics of UHV class gas circuit breakers by changing the nozzle shape. To calculate the dielectric recovery voltage between electrodes, the flow field and electric field analysis in a 362kV model interrupter has been performed with the commercial programs, RAMPANT and FLUX2D, respectively. As a result, we found that the nozzle shape affects the characteristics of dielectric recovery between electrodes and obtained great improvement of it by the changing the downstream nozzle shape.

  • PDF

부분방전을 이용한 초고압 지중 송전 절연 케이블 내부 결함의 패턴분석 (Pattern Analysis of the Defects within the Cable Insulation for UHV Underground Transmission Using Partial Discharge)

  • 박재화;이광열;채석;오영석;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.175-179
    • /
    • 1998
  • The insulation of cable which used for Ultra-High Voltage(UHV) underground power transmission requires excellent insulation capability for high voltage. The typical insulation materials are used XLPE, EPR, etc, but insulation efficiency of these is affected by void or alien substances, existed at the inside of insulators. In this paper, the partial discharge patterns of the defects within insulation cable are observed and analyzed. In this test, void, fiber and metal inclusions which possibly exist in cables, are simulated and investigated the patterns of partial discharges for each models Also the relations between calculated field strength and the insulation breakdown voltage. The experiment shows distinct partial discharge patterns in accordance with the kinds of defects within Insulation cable.

  • PDF

초고압 절연시험을 위한 4.2MV 충격전압발생장치의 구축방안 검토 (A preliminary study on the construction of 4.2MV IVG for the UHV dielectric test)

  • 이정기;신영준;허종철;문인욱;김맹현;강영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1750-1752
    • /
    • 2003
  • This paper, as a preliminary study, presents the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kv-class. To fix and confirm the kinds of loads and their capacities to be tested by KERI hereafter, wide investigation and an analysis of test objects, especially heavy electric apparatus of Korea, according to their ratings and test voltages have been conducted. With the special consideration concerning other matters in designing of 4.2MV IVG have been described with the practical examples and references.

  • PDF

Critical seismic incidence angle of transmission tower based on shaking table tests

  • Tian, Li;Dong, Xu;Pan, Haiyang;Gao, Guodong;Xin, Aiqiang
    • Structural Engineering and Mechanics
    • /
    • 제76권2호
    • /
    • pp.251-267
    • /
    • 2020
  • Transmission tower-line systems have come to represent one of the most important infrastructures in today's society. Recent strong earthquakes revealed that transmission tower-line systems are vulnerable to earthquake excitations, and that ground motions may arrive at such structures from any direction during an earthquake event. Considering these premises, this paper presents experimental and numerical studies on the dynamic responses of a 1000 kV ultrahigh-voltage (UHV) transmission tower-line system under different seismic incidence angles. Specifically, a 1:25 reduced-scale experimental prototype model is designed and manufactured, and a series of shaking table tests are carried out. The influence of the seismic incidence angle on the dynamic structural response is discussed based on the experimental data. Additionally, the incidence angles corresponding to the maximum peak displacement of the top of the tower relative to the ground (referred to herein as the critical seismic incidence angles) are summarized. The experimental results demonstrate that seismic incidence angle has a significant influence on the dynamic responses of transmission tower-line systems. Subsequently, an approximation method is employed to orient the critical seismic incidence angle, and a corresponding finite element (FE) analysis is carried out. The angles obtained from the approximation method are compared with those acquired from the numerical simulation and shaking table tests, and good agreement is observed. The results demonstrate that the approximation method can properly predict the critical seismic incidence angles of transmission tower-line systems. This research enriches the available experimental data and provides a simple and convenient method to assess the seismic performance of UHV transmission systems.