• Title/Summary/Keyword: UHF sensor

Search Result 109, Processing Time 0.028 seconds

The Production and Measurement of Cavity-Sensor for Insulation Diagnosis (절연진단용 Cavity 센서의 제작 및 측정)

  • Lee, Chang-Hun;Lee, Chang-Uk;Choi, Eun-Hyuck;Kim, Jung-Bea;Kim, Gi-Chai;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1462-1463
    • /
    • 2007
  • GIS와 같은 전력기기들은 내부에 다양한 원인에 따라 이 결함에 의해 절연열화가 진전되는 것이 일반적인 현상이며, 결국 사고로 이어지게 된다. 따라서 절연열화과정에서 부분방전 현상에 의한 전자파 신호를 보다 효율적으로 검출할 수 있는 센서를 설계하기 위해 본 논문에서는 UHF 대역의 측정이 가능한 Cavity 안테나를 이용하여 절연진단기술에서의 적용가능성을 검토해 보았다.

  • PDF

Filter Test for Partial Discharge Detection of Underground Distribution Cables (지중배전케이블의 PD 검출용 필터 시험 연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF

Telemetry capsule for pressure monitoring in the gastrointestinal tract (소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현)

  • Yoon, Ki-Won;Woo, Sang-Hyo;Lee, Jyung-Hyun;Moon, Yeon-Kwan;Park, Hee-Joon;Won, Chul-Ho;Kim, Byung-Kyu;Choi, Hyun-Chul;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.211-218
    • /
    • 2005
  • As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.

Design of 13.56 MHz RFID Tag IC (13.56 MHz RFID 태그 집적회로 설계)

  • Youn, Nam-Won;Kwon, Young-Jun;Shin, Bong-Jo;Park, Keun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.309-312
    • /
    • 2005
  • The RFID tag IC has been presently abstracting great attention in the world because it can be one of the important sensor elements in the ubiquitous sense network in the future. The 125 kHz and 13.56 MHz RFID tag IC's have already been developed and now widely used in the world and the UHF band tag IC is under development. Domestically, the development of the 125 kHz tag IC was reported before, but there has been no report about the development of the 13.56 MHz tag IC up to now. In this paper, the results of the design, fabrication and measurement of a 13.56 MHz tag IC are discussed. The digital and the analog circuits for the chip were designed and the chip was fabricated using 0.35 ㎛ standard CMOS technology and measured with a separately prepared reader. It was found from the measurement results that it operated properly within 8 cm range of the reader.

A Study on the International Standard for CCM Related RFID Packaging Technology (CCM(Cold Chain Management)과 연계된 RFID 패키징 국제 기술 표준의 분석)

  • Yoon, Seong-Young;Cha, Kyong-Ho;Park, Su-Il;Kim, Jai-Neung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.15 no.2
    • /
    • pp.67-73
    • /
    • 2009
  • The introduction of radio frequency identification (RFID) technology into cold chain system will be essentials for the better quality preservation of chilled products in the near future. The object of this study is to analyze the trends of international standardization activity for cold chain system and RFID packaging. The standardization of RFID technology is related to SC31 of ISO/IEC JTC1. The established standard from EPCglobal includes the air interface of UHF substitute actors, the control of EPC tag data and the event collected from RFID readers, the directory services and information storage of ONS and EPCIS, and securities. Also, EPC standards include the sensor functions of the cold chain. In Korea, the RFID packaging related techniques and their engineering standard are less studied as compared with Europe or North America. For effective application of RFID in the cold chain and packaging, scientific and systematic researches on RFID, including technical standards for domestic RFID frequency, will be key elements for preoccupation of these application techniques.

  • PDF

Discrimination of Insulation Defects in a Gas Insulated Switchgear (GIS) by use of a Neural Network Based on a Chaos Analysis of Partial Discharge (CAPD)

  • Jung, Seoung-Yong;Ryu, Cheol-Hwi;Lim, Yun-Sok;Lee, Ja-Ho;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.118-122
    • /
    • 2007
  • In this work, experimental investigation is carried out in order to design and fabricate the UHF sensor that is able to detect the partial discharges produced from 10 artificial defects introduced into the real scale 70kV GIS mock-up under high voltage within a well shielded room. As well, in order to verify the on-site applicability of our method, the newly proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis for identifying the nature of 10 artificial defects under investigation. The PD pattern recognition of each defect has been fulfilled by applying our ANN software. The result indicates that the recognition rate reaches up to 80% by the newly proposed method while the traditional PRPD analysis method allows us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

Discrimination of insulation defects in a Gas Insulated Switchgear (GIS) by use of a neural network based on a Chaos Analysis of Partial Discharge(CAPD) (카오스이론을 이용한 GIS 내부 절연결함 판별)

  • Lim, Yun-Seok;Lee, Dong-Il;Koo, Ja-Yoon;Kim, Jeong-Tae;Bang, Hang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2223-2225
    • /
    • 2005
  • In this work, experimental investigation has been mainly done. For this purpose, UHF sensor has been designed and fabricated to detect the partial discharges produced from the 10 artificial defects introduced into the real scale 70kV GIS mock-up under the high voltage at the well shielded room. And also, in order to verify the applicability of the proposed method at the site, the proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis method in order to identify the nature of the above 10 defects. The PD pattern recognition of each defect has been fulfilled by applying self developed artificial neural network soft ware. The result shows that the recognition rate is reached to be 80% by newly proposed method while the traditional PRPD analysis method leads us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

  • PDF

Development of Capacitive Sensing Based Self-sustainable Water Monitoring Sensor Node for Plant Growth Management (정전용량 센싱기반 식물생장관리용 자기유지 지원 수분 모니터링 센서노드 설계)

  • Song, Min-Hwan;Lee, Sang-Shin;Won, Kwang-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.986-988
    • /
    • 2012
  • 최적의 식물 생장을 위해서는 적절한 수분의 유지가 필수적이며 넓은 지역, 다양한 종류, 고가의 식물의 경우일수록 적절한 수분의 관리를 위한 시스템의 도움이 필요하다. 이를 위해 저가의 센서노드 시스템이 적절한 해결책이 될 수 있으나 일반적인 배터리 기반의 센서노드 시스템을 적용시 배터리 용량 확인 및 교체 등의 유지보수 문제가 대두된다. 본 논문에서는 이러한 유지보수의 문제를 해결하고 식물재배에 도움을 줄 수 있는 자기유지 지원 방식의 정전용량 센싱기반의 수분 모니터링 센서노드를 설계하였다. UHF 기반의 무선 전력 전송의 자기유지 지원 시스템 및 PCB 패턴기반의 정전용량센싱 수분센서와 초저전력 센서노드 시스템으로 구성된다. 센서노드는 한번 송신시 약 0.24 mJ을 소모하며 에너지획득모듈은 에너지 획득 주기마다 약 4 mJ의 에너지를 공급하도록 설계하여 센서동작을 위한 충분한 에너지 마진을 주도록 설계하였다.

Investigation on Oil-paper Degradation Subjected to Partial Discharge Using Chaos Theory

  • Gao, Jun;Wang, Youyuan;Liao, Ruijin;Wang, Ke;Yuan, Lei;Zhang, Yiyi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1686-1693
    • /
    • 2014
  • In this paper, oil-paper samples composed of transformer windings were used to investigate the insulation degradation process subjected to partial discharge (PD), with artificial defects inside to simulate the PD induced insulation degradation. To determine appropriate test voltages, the breakdown time obtained through a group of accelerated electrical degradation tests under high voltages was firstly fitted by two-parameter Weibull model to acquire the average breakdown time, which was then applied to establish the inverse power law life model to choose advisable test voltages. During the electrical degradation process, PD signals were synchronously detected by an ultra-high frequency (UHF) sensor from inception to breakdown. For PD analysis, the whole degradation process was divided into ten stages, and chaos theory was introduced to analyze the variation of three chaotic parameters with the development of electrical degradation, namely the largest Lyapunov exponent, correlation dimension and Komogorov entropy of PD amplitude time series. It is shown that deterministic chaos of PD is confirmed during the oil-paper degradation process, and the obtained results provide a new effective tool for the diagnosis of degradation of oil-paper insulation subjected to PD.