• Title/Summary/Keyword: U-tube

Search Result 383, Processing Time 0.036 seconds

Thermoelectric Efficiency Improvement in Vacuum Tubes of Decomposing Liquid Lithium-Ammonia Solutions (진공튜브 속에서 분해하는 리튬암모니아 솔루션의 열전효율 향상)

  • Lee, Jungyoon;Kim, Miae;Shim, Kyuchol;Kim, Jibeom;Jeon, Joonhyeon
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.358-363
    • /
    • 2013
  • Lithium-ammonia (Li-$NH_3$) solutions are possible to be successfully made under the vacuum condition but there still remains a problem of undergoing stable and reliable decomposition in vacuum for high-efficiency thermoelectric power generation. This paper describes a new method for improving the thermoelectric conversion efficiency of Li-$NH_3$ solutions in vacuum. The proposed method uses a 'U'-shaped Pyrex vacuum tube for the preparation and decomposition of pure fluid Li-$NH_3$ solutions. The tube is shaped so that a gas passageway ('U') connecting both legs of the 'U' helps to balance pressure inside both ends of the tube (due to $NH_3$ gasification) during decomposition on the hot side. Thermoelectric experimental results show that solution reaction in the 'U'-shaped tube proceeds more stably and efficiently than in the 'U'-shaped tube, and consequently, thermoelectric conversion efficiency is improved. It is also proved that the proposed method can provide a reversible reaction, which can rotate between synthesis and decomposition in the tube, for deriving the long-time, high-efficiency thermoelectric power.

Sensitivity Analysis on Design Factor of Ground Heat Exchanger for Optimum Design of Vertical Ground Source Heat Pump System (수직밀폐형 지중열교환기의 최적설계를 위한 설계인자 영향도 분석)

  • Bae, Sangmu;Kim, Hongkyo;Nam, Yujin
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.87-93
    • /
    • 2018
  • Ground source heat pump(GSHP) system is one of the high efficiency heat source systems which utilizes the constant geothermal energy of a underground water or soil. However, the design of conventional GSHP system in the domestic market is dependent on the experience of the designer and the installer, and it causes increase of initial installation cost or degradation of system performance. Therefore, it is necessary to develop a guideline and the optimal design method to maintain stable performance of the system and reduce installation cost. In this study, in order to optimize the GSHP system, design factors according to ground heat exchanger(GHX) type have been examine by simulation tool. Furthermore, the design factors and the correlation of a single U-tube and a double U-tube were analyzed quantitatively through sensitivity analysis. Results indicated that, the length of the ground heat exchanger was greatly influenced by grout thermal conductivity for single U-tube and pipe spacing for double U-tube.

A Study on Heat Transfer Performance of Vertical Ground Heat Exchanger of GSHP(Ground Source Heat Pump) (GSHP용 수직형 지중열교환기의 열전달 성능에 관한 연구)

  • Chung, Min-Ho;Chang, Ki-Chang;Ra, Ho-Sang;Baik, Young-Jin;Park, Seong-Ryong;Yoo, Seong-Yeon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2102-2107
    • /
    • 2007
  • GSHP systems are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal and vertical type according to the installation method. Vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double u-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

Effects of Ice pack application for the postcardiac surgery toddlers before C-tube removal (심장수술 환아의 흉관제거시 통증에 대한 냉요법의 효과)

  • 신희선;김동옥;조경미
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.2
    • /
    • pp.341-350
    • /
    • 1995
  • A quasi-experimental study was conducted to examine the effect of ice pack application to post cardiac surgery toddlers before C-tube removal. Twenty toddlers aged 13 months to 24 months, who were admitted to the hospital for open heart surgery during the period from July, 1993 to October, 1993 were randomly assigned to the experimental or control group. An ice pack was applied to the C-tube insertion site for 8 minutes before C-tube removal for the experimental group. The children were videotaped during the procedure to assess pain behavior and crying time. The score on the Modified Behavioral Pain Scale(MBPS), crying time, and vital signs were measured to determine the effect of ice pack application. The data were analyzed using Mann-Whitney U test, Paired t-test, and Pearson correlation coefficient. The result of the study are as follows : 1. There was a significant difference between the experimental group and the control group in pain behavior (U=17.0, p=.01). 2. There was no significant difference between the two groups in crying time. 3. There was a significant difference between the two groups in heart rate (U=24.5, p=.05). 4. There was a significant difference between the two groups in systolic blood pressure (U=24.0, p=.05) 5. There was a significant difference between the two groups in diastolic blood pressure (U=23.0, p=.04). 6. There was no significant difference between the two groups in respiration rate. 7. Pain behavior was significantly correlated with heart rate, systolic blood pressure, and crying time (r=.50, .54 and .59, p<.05). The result showed that the ice pack application was effective to reduce pain related to C-tube removal for the toddlers. From the study, it is recommended that the effectiveness of the cold ap-plication to children undergoing different painful procedures be examined to determine the most effective length of cold application to reduce pain in children.

  • PDF

Observation of the Preionization effect and Operational Characteristics of a Nitrogen Laser by a Pulse type high Voltage Power Supply (펄스형 고전압 전원에 의한 선전리 현상의 관측과 질소레이저의 동작 특성)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2006
  • We constructed a TEA $N_2$ laser which consists of spark gap, pulse type high voltage power supply, Blumlein transmission line circuit, laser tube with Ernst electrode. We observed the self-preionization with an optical fiber in the spark gap and laser tube. The higher voltage power supplied to the Blumlein transmission line circuit, the better preionization was. An U-type transformer yielded better stability and output power than an I-type transformer. The discharge time after triggering a spark gap for the U-type transformer was also short. We obtained the stability of $2.7\%$ and output power of $36{\mu}J$ when the optimum conditions of the laser operation were spark gap distance of 6.0 mm, electrode distance in laser tube of 5.0 mm, $N_2$ gas flow rate in spark gap of 1500 cc/min, $N_2$ gas flow rate in laser tube of 4 ${\iota}$/min, output window reflectivity of $40\%$ and repetition rate of 10 Hz.

Condensation heat transfer for refrigerant-oil mixtures in microfin tube condenser (마이크로핀관 응축기 내 냉매-냉동기유 혼합물의 전열 특성)

  • Cho, Keum-Man;Tae, Sang-Jin
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.90-95
    • /
    • 2000
  • Condensation heat transfer experiments for R-22 and R-407C refrigerants mixed with mineral oil and POE oil respectively were performed in straight and U-bend sections of a microfin tube. Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to $400 kg/m^2s$ and an inlet quality from 0.5 to 0.9. The enhancement factors for R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass flux decreased and inlet quality increased. The heat transfer coefficients in the U-bend were the maximum at the $90^{\circ}$ position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficients at the first straight section.

  • PDF

Vibration Characteristics of Steam Generator U-tubes with Defect (결함을 가진 증기발생기 U-튜브의 진동특성)

  • 조종철;정명조;김웅식;김효정;김태형
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.5
    • /
    • pp.400-408
    • /
    • 2003
  • This paper investigates the vibration characteristics of steam generator (SG) U-tubes with defect. The operating SG shell-side flow field conditions for determining the fluidelastic instability parameters such as added mass are obtained from three-dimensional SG flow calculation. Modal analyses are performed for the U-tubes either with axial or circumferential flaw with different sizes. Special emphases are on the effects of flaw orientation and size on the modal and instability characteristics of tubes, which are expressed in terms of the natural frequency, corresponding mode shape and stability ratio. Also, addressed is the effect of the internal pressure on the vibration characteristics of the tube.

A Dynamic Model of U-Tube Steam Generator for CANDU Simulation

  • Lim, Jae-Cheon;Seoungyon Cho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.213-218
    • /
    • 1996
  • A simulation model for the transient behavior of CANDU U-tube steam generator(UTSG) has been developed for application to the simulation of operational transient behavior of CANDU nuclear power plant. For application to CANDU UTSG. tile design characteristics of CANDU UTSG such as Wolsong Units, feedwater inlet near the tube sheet. is approximated. For realistic prediction of thermal hydraulic behavior of and tube bundle region is divided into two separate control volumes, subcooled region and saturated region. and the variation of thermal hydraulic properties within a control volume is considered. Test results for typical CANDU operational transient case show reasonable transient behavior of steam generator and considered to be applicable to the simulation of overall plant.

  • PDF

The Effects of Sample Disturbance on Undrained Properties of Yangsan Clay (양산점토의 비배수 특성에 대한 시료교란의 효과)

  • 김길수;임형덕;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.639-646
    • /
    • 2000
  • It is important to estimate the mechanical properties of clay since it is directly related to the design and the construction of geotechnical structures. Site exploration, which is composed of boring, sampling, in-situ, or laboratory tests, is preformed to estimate the mechanical properties. However, mechanical properties of clay measured from laboratory test may be different from in-situ properties due to disturbances occurred during sampling, transportation, storage, and trimming. In this study, the degree of disturbance according to sampling method was estimated with the test results of CK/sub o/U triaxial compression test on Yangsan clay. The soil samples were obtained by three types of sampling method, j.e., 76mm-tube sampler, 76mm-piston sampler, and block sampler. In order to evaluate the quality of samples, volumetric strain, undrained shear strength, secant Young's modulus, and pore pressure coefficient at peak measured from each sample were compared with one another. From the test results, it was observed that mechanical properties of the block and piston samples were more reliable than those of tube samples. But it was observed that the water content of piston was similar to that of tube samples at given depths while the water content of block samples was 14.3∼15.8% smaller than that of piston and tube samples. In addition to the evaluation of the quality of samples, relationship between c/sub u// σ/sub vc/'and OCR was established from the results of the CK/sub o/U triaxial compression tests, which were carried out using SHANSEP method. And also undrained shear strength was analyzed using the in-situ test data such as Cone Penetration Test(CPT), Dilatometer Test(DMT), and Field Vane Test(FVT) and was compared with that evaluated from CK/sub o/U triaxial compression test.

  • PDF