• Title/Summary/Keyword: U-shape pipe

Search Result 16, Processing Time 0.023 seconds

Effect of Wall Thinned Shape and Pressure on Failure of Wall Thinned Nuclear Piping Under Combined Pressure and Bending Moment (감육형상 및 내압이 원자력 감육배관의 파단에 미치는 영향 -내압과 굽힘모멘트가 동시에 작용하는 경우-)

  • Shim, Do-Jun;Lim, Hwan;Choi, Jae-Boong;Kim, Young-Jin;Kim, Jin-Won;Park, Chi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.742-749
    • /
    • 2003
  • Failure of a pipeline due to local wall thinning is getting more attention in the nuclear power plant industry. Although guidelines such as ANSI/ASME B31G and ASME Code Case N597 are still useful fer assessing the integrity of a wall thinned pipeline, there are some limitations in these guidelines. For instance, these guidelines consider only pressure loading and thus neglect bending loading. However, most Pipelines in nuclear power plants are subjected to internal pressure and bending moment due to dead-weight loads and seismic loads. Therefore, an assessment procedure for locally wall thinned pipeline subjected to combined loading is needed. In this paper, three-dimensional finite element(FE) analyses were performed to simulate full-scale pipe tests conducted for various shapes of wall thinned area under internal pressure and bending moment. Maximum moments based on true ultimate stress(${\alpha}$$\sub$u,t/) were obtained from FE results to predict the failure of the pipe. These results were compared with test results, which showed good agreement. Additional finite element analyses were performed to investigate the effect of key parameters, such as wall thinned depth, wall thinned angle and wall thinned length, on maximum moment. Also, the effect of internal pressure on maximum moment was investigated. Change of internal pressure did not show significant effect on the maximum moment.

Evaluation of a Ground Heat Exchanger Appropriate for the Site of the Third Stage Construction of Incheon International Airport (인천국제공항 3단계 건설부지에 적합한 지중열교환기 시스템 평가 연구)

  • Cho, Nam-Hyun;Song, Jung-Tae;Yoon, Seok;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.23-33
    • /
    • 2015
  • In the present study, a ground heat exchanger was installed for each heat source in the system at the site to evaluate ground heat conductivity, constructability, and economic feasibility; the factors considered in the study included ground heat, groundwater, fillers (such as bentonite and pea pebbles) and the shape of the heat exchange pipe (e.g., U and D-U). The aim was to determine the ground heat exchanger appropriate for the geothermal system in the 3rd-phase construction of Incheon International Airport. A comparative cost analysis of the initial costs based on the above information showed that although the initial costs of the regular vertical closed loop-II and modified vertical closed loop were lower than those of the regular vertical closed loop-I, they could not be expected to deliver high economic efficiency from the viewpoint of constructability (filler injection, heat exchange pipe insertion). The initial costs proved to be higher in the case of Geohil.

The Development and its Application of Diagnostic Technique for Corrosion Defect of U-type Open Rack Vaporizer (개방형 U-type 기화기의 부식손상부 진단기법 개발 및 적용)

  • Jang S. Y.;Lee S. M.;Oh B. T.;Kho Y. T.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.45-50
    • /
    • 2001
  • Open rack vaporizer (ORV) has been used in liquefied natural gas (LNG) receiving terminal in order to vaporize LNG into natural gas (NG) by heat exchange with seawater The U-type ORV which had been operated with seawater for 14 years is one of the important utilities of the gas production and the weld part of tube connected with header_ pipe had experienced many corrosion problems. To elucidate the cause of corrosion at weld part of vaporizer tube, corrosion potentials were compared by parts. This study concerns on the measurement of corrosion pit depth using non-destructive method and the evaluation of stress distribution in an aspect of safety with finite element analysis. In order to confirm the reliability of galvanic corrosion between weld parts and base metal, the measurement of corrosion potential by parts was conducted for 20 minutes in 3.5$\%$(wt.) NaCl solution. Many non-destructive methods were tried to measure the remaining thickness of vaporizer tube at fields. For general corrosion, tangential radiography test was confirmed as an effective method. In case of a fine corrosion pit, the shape of corrosion pit was reproduced using surface replication method. From collected data, stress distributions were quantitatively evaluated with 2-dimensional finite element method and the diagnostic evaluation on internal pressure of the U-type vaporizer could be made.

  • PDF

Effect of Plastic Injection on the Blast Furnace Operation Under One-Tuyere Test (플라스틱의 풍구 1본 시험흡입에 따른 고로조업영향)

  • 허남환;임창희
    • Resources Recycling
    • /
    • v.7 no.2
    • /
    • pp.16-22
    • /
    • 1998
  • Recently, the new technology for the recycling of waste plastics as an alternative he1 of blast furnace ha been developed. In this shldy, the test of plastics injection into a tuyere af the foundry blast furnace were carried out. The injection rate of plastics far this tcst facility war expressed as follows, ${W}_{s}=0.265\frac{{delta}PA}{U}_{g}$, where. Ws, AP, A and Ug are plastic conveying ratc (kgisec), pressure drop between feed hopper and blaqt pressure (alm), cross sectional area of conveying pipe (mi) and superficial velocity of transport air (mhzc) respcctiuely. From the results of semi-continuous test operation during 96 hours, the replacement raho mned out to be 1.38 according to the injection rate of 6. 4 kg-plasticsit-p. With increasing the rate of plaslics injcchon, the content of hydrogen in top gas became increased and the brick temperahlre at bzlly was also increased due to Lhe changes ot the combustion zone shape.

  • PDF

Numerical Analysis on the Characteristics of Supersonic Steam Jet Impingement Load (초음속 증기제트의 충돌하중 특성에 대한 수치해석 연구)

  • Oh, Se-Hong;Choi, Dae Kyung;Park, Won Man;Kim, Won Tae;Chang, Yoon-Suk;Choi, Choengryul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.2
    • /
    • pp.1-10
    • /
    • 2018
  • Structures, systems and components of nuclear power plants should be able to maintain safety even in the event of design-basis accidents such as high-energy line breaks. The high-pressure steam jet ejected from the broken pipe may cause damage to the adjacent structures. The ANSI/ANS 58.2 code has been adopted as a technical standard for evaluating the jet impingement load. Recently, the U.S. NRC pointed out the non-conservativeness of the ANSI/ANS 58.2, because it does not take into account the blast wave effect, dynamic behavior of the jet, and oversimplifies the shape and load characteristics of the supersonic steam jet. Therefore, it is necessary to improve the evaluation method for the high-energy line break accident. In order to evaluate the behavior of supersonic steam jet, an appropriate numerical analysis technique considering compressible flow effect is needed. In this study, numerical analysis methodology for evaluating supersonic jet impingement load was developed and verified. In addition, the conservativeness of the ANSI/ANS 58.2 model was investigated using the numerical analysis methodology. It is estimated that the ANSI jet model does not sufficiently reflect the physical behavior of under-expanded supersonic steam jet and evaluates the jet impingement load lower than CFD analysis result at certain positions.

Analysis of Rana coreana Behavior According to the Slope Angle Degree of Escape Ramp (콘크리트 수로 탈출로 경사각에 따른 한국산개구리 행동 분석)

  • Lee, Taeho;Kim, Jungkwon;Seo, Jihye;Jang, Moonjeong;Choi, Taeyoung;Chang, Minho
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2022
  • The purpose of this study is to propose the angle-limit of the escape ramp by analyzing the frog behavior characteristics according to the inclination angle of the waterway escape ramp installed in the concrete U-bench plume pipe channel. Forthe experiment, an escape test device was manufactured with the same shape and number of materials applied in the field. And Rana coreana living in paddy wetlands were sel selected. The main behaviors of frogs on the slope were 'jumping', 'crawling' and 'slipping', and afterrecording the behavioralresults according to the inclination angle, statistical analysis was conducted using the chi-square test method. As a result of the analysis, there was no statistically significant difference between 30° and 40°. This result is an evidence for expanding the standard of inclination angle 30° suggested in the 'Guidelines for Installation and Management of Ecological Pathways' to a maximum of 40°. However, further research is required in that the escape ramp targets not only Korean frogs but also various small wild animals. However, considering that various wild animals are affected by artificial canals, additional studies using various target wild animals are needed.