• Title/Summary/Keyword: U-shape pipe

Search Result 16, Processing Time 0.026 seconds

Evaluation of Residual Stress Effect about Fatigue Characteristic of U-shaped Structure (U자형 구조의 피로특성에 대한 잔류응력의 영향 평가)

  • Kim, Sang-Young;Koo, Jae-Mean;Seok, Chang-Sung;Mo, Jin-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.79-86
    • /
    • 2010
  • Mechanical structures with power sources experience repeated force produced by motors. In result, the life of the pipes reduces and ultimately, the pipes collapse. Such pipes are formed into several shapes and particularly, the U-shape pipe is damaged frequently. In most cases, the U-shape pipe is made with a straight pipe by complicated bending work. During this work process, plastic deformation of the pipe produces residual stress in the pipe. This residual stress significantly affects the fracture behavior of the pipe and induces the change of the stress ratio (min. stress/Max. stress = R). For this reason, residual stress has to be evaluated. In this paper, the residual stress of a U-shaped pipe was evaluated by FEM analysis. In addition, fatigue tests of the U-shaped pipe were performed by using a uniaxial fatigue testing machine. The results of the fatigue test were modified with the results of FEM (Finite Element Method) analysis for residual stress. The modified fatigue test results of the U-shaped pipe were compared with those of a straight pipe.

A Study on the Operational Characteristics of a U-shape Heat Pipe (U형 히트파이프의 작동 특성에 관한 연구)

  • Gang, Hwan-Guk;Kim, Cheol-Ju;Lee, Yong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1711-1720
    • /
    • 2001
  • In this study, the heat transfer characteristics of a U-shape heat pipes were investigated. Heat is supplied to the U heat pipe through its middle zone(evaporator), and is released to the environment through its both arms(condensers). Both heat transfer coefficients and heat transport limitations were measured and compared with correlations previously developed for straight type heat pipes. Special concerns were focused to the cases, when each of condensers were submitted to a different cooling conditions, relatively. As a result. the heat transfer limitation of a U-shape heat pipe was found out to be 10∼15% less than the value for a straight heat pipe with an equivalent size.

Heat Transfer Characteristics of the U-shape Heat Pipe using Working Fluid of PFC (PFC 작동유체 사용 U형 히트파이프의 열전달특성 연구)

  • 이기우;박기호;전원표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.796-802
    • /
    • 2001
  • The purpose of the present study is to examine the heat transfer characteristics of the U-shape heat pipe for the cooling of semiconductor in subway train. Perflouro-carbon(PFC) was used as working fluid. Temperature distribution on the surface and heat transfer coefficients were investigated according to the working fluid volume percent and heating rate. The results were as follows; Optimum volumetric percent of working fluid was from 80% to 90%, and hat transfer coefficients of evaporation and condensation were as follows, respectively. $\hbar_ie=0.37\times(\frac{P_i}{P_O})$l_c}^0.3$,$\hbar_ic-4.2(\frac{\kappa_l^3p_l^2gh_fg}{\mu_lq_c_l_c}^\frac{1}{3}

  • PDF

Deformation analysis of copper pipe for hair pin under the bending forming using the Mandrel (맨드릴을 사용한 굽힘 성형시 헤어핀용 동관의 변형 해석)

  • 김광영;윤두표
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1630-1633
    • /
    • 2003
  • Hair pin bending machine is pipe forming machine consisting of heat exchanger product system. Hair pin produced by these machine is pathway of refrigerant and play a important role improving the performance and productivity of heat exchanger. The core technology of hair pin bending machine is forming the straight pipe into U-type without any defaults. Therefore, this paper study the relation between the pipe bending forming and the shape and position of mandrel using the elastic-plastic finite element analysis and provide a foundation technology for which developing the hair pin bending machine. The results are followed 1. Mandrel located in front of rotating center of bending die minimized the circular shape variation of copper pipe. 2. Diameter change of mandrel hardly effect the pipe shape.

  • PDF

Explicit Equations of Normal Depth for Drainage Pipes (하수관 등류수심 양해법 산정식)

  • Yoo, Dong-Hoon;Rho, Jung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.527-535
    • /
    • 2005
  • The computation of normal depth is very important for the design of channel and the analysis of water flow. Drainage pipe generally has the shape of curvature like circular or U-type, which is different from artificial triangular or rectangular channel. In this case, the computation of normal depth or the derivation of equations is very difficult because the change of hydraulic radius and area versus depth is not simple. If the ratio of the area to the diameter, or the hydraulic radius to the diameter of pipe is expressed as the water depth to the diameter of pipe by power law, however, the process of computing normal depth becomes relatively simple, and explicit equations can be obtained. In the present study, developed are the explicit normal depth equations for circular and U-type pipes, and the normal depth equation associated with Hagen (Manning) equation and friction factor equation of smooth turbulent flow by power law is also proposed because of its wide usage in engineering design.

Evaluation of performance of closed-loop vertical ground heat exchanger by In-situ thermal response test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Kwak, Tae-Hoon;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.229-239
    • /
    • 2010
  • Performing a series of in-situ thermal response tests, the effective thermal conductivity of six vertical closed-loop ground heat exchangers was experimentally evaluated and compared each other, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than that of bentonite grouting, and the efficiency of graphite better performs over silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance.

  • PDF

Evaluation of Performance of Grouts and Pipe Sections for Closed-loop Vertical Ground Heat Exchanger by In-situ Thermal Response Test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기용 그라우트와 열교환 파이프 단면의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Choi, Hang-Seok;Sohn, Byong-Hu
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.93-106
    • /
    • 2010
  • In performing a series of in-situ thermal response tests, the effective thermal conductivities of six vertical closed-loop ground heat exchangers were experimentally evaluated and compared one another, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than bentonite grouting, and the efficiency of graphite better performs than silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance. Based on the results from the in-situ thermal response tests, a series of economic analyses have been made to show the applicability of the new addictives and 3 pipe-type heat exchanger.

A Study on the Economic Repair Pattern of the Building Components in the Apartment Housing (공동주택 구성재의 경제적 수선형태 설정 연구)

  • Lee, Kang-Hee;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.87-95
    • /
    • 2006
  • Building components have been deteriorated by various factors such as location, a building type, a surrounding environment and so on. In addition, each component has a peculiar characteristics, compared with other components in properties of matter an used part. Building components would be required to maintain its function and performance to provide the resident with a decent living condition. It is important to decide the repair time, scope and a required cost in repair plan, considering the each component's characteristics. In this parer, it aimed at providing the economic repair pattern to analyze the relation of the time-elapse and the cumulative repair cost in the apartment housing using 3rd quadratic function. Results of the study are as follows: First, the shape of the function for the economic repair is classified into two type. One is the continuous increase type of the cumulative cost which properly means the iterative repair type after built. The other is that the function has the maximum state at a point which means one-repair after its repair would be delayed to a scheduled time. Second, the iterative repair pattern would include window, roof proof, lighting and water supply pipe. The other repair pattern would include the paintings, heating pipe and sign board.