• Title/Summary/Keyword: U-Mo Fuel

Search Result 56, Processing Time 0.031 seconds

Molybdenum release from high burnup spent nuclear fuel at alkaline and hyperalkaline pH

  • Sonia Garcia-Gomez;Javier Gimenez;Ignasi Casas;Jordi Llorca;Joan De Pablo;Albert Martinez-Torrents;Frederic Clarens;Jakub Kokinda;Luis Iglesias;Daniel Serrano-Purroy
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.34-41
    • /
    • 2024
  • This work presents experimental data and modelling of the release of Mo from high-burnup spent nuclear fuel (63 MWd/kgU) at two different pH values, 8.4 and 13.2 in air. The release of Mo from SF to the solution is around two orders of magnitude higher at pH = 13.2 than at pH = 8.4. The high Mo release at high pH would indicate that Mo would not be congruently released with uranium and would have an important contribution to the Instant Release Fraction, with a value of 5.3%. Parallel experiments with pure non irradiated Mo(s) and XPS determinations indicated that the faster dissolution at pH = 13.2 could be the consequence of the higher releases from metallic Mo in the fuel through a surface complexation mechanism promoted by the OH- and the oxidation of the metal to Mo(VI) via the formation of intermediate Mo(IV) and Mo(V) species.

Determination of La in $U_3Si/Al$ Spent Nuclear Fuel by Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry (Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry에 의한 $U_3Si/Al$ 사용후핵연료 중 La의 분리 및 정량)

  • Han, Sun Ho;Choi, Kwang Soon;Kim, Jung Suk;Jeon, Young Shin;Park, Yang Soon;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.601-607
    • /
    • 2000
  • Lanthanum has been used as one of the burnup monitor in spent nuclear fuel. $U_3Si/Al$ spent nuclear fuel contains small amount of La in high concentration of U and Al. Therefore, chemical separation of La is required to remove matrix elements. At first, ion chromatography (IC) and inductively coupled plasma systems were installed in radiation shielded glove box to handle the radioactive samples. Retention behavior of uranium, aluminum, lanthanum and some interesting fission products (Sr, Zr, Y, Mo, Ru, Pd, Rh, Cs, Ba, Ce, Pr, Nd, Sm, Eu and Cd) was investigated using the CG10 column and ${\alpha}$-HiBA eluent. As all elements were eluted earlier than lanthanum in 0.2 M ${\alpha}$-HiBA eluent, a portion of U and Al was directly passed to waste using a three way valve between the column and the nebulizer. Thus it was possible to determine the lanthanum in a high concentration of U and Al matrix. Retention time of La was about 12 minutes in this separation condition. Optimum range for the determination of La in $U_3Si/Al$ spent nuclear fuel was $1-10{\mu}g/L$ (ppb) with this system and detection limit was $0.25{\mu}g/L$ in case of $200{\mu}L$ of sample volume.

  • PDF

Analysis of High Radioactive Materials in Irradiated DUPIC SIMFUEL Using EPMA (EPMA를 이용한 DUPIC 사용후 핵연료 핵분열 생성물의 특성 분석)

  • 정양홍;유병옥;주용선;이종원;정인하;김명한
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.125-133
    • /
    • 2004
  • Fission products of DUPIC (Direct Use of Spent PWR Fuel in CANDU Reactors) fuel, irradiated in HANARO research reactor with 61 ㎾/m of maximum linear power and 1,770 ㎿d/tU of average burn-up, was characterized by EPMA(Electron Probe Micro Analyzer). In order to find accurate characterization, the analysis results by EPMA of fresh simulated DUPIC fuel containing fission products as chemicals were compared with that of wet chemical analysis. The metallic precipitates observed at the center of the fresh simulated DUPIC fuel were about 1 $\mu\textrm{m}$ in size and their major components by EPMA were Mo-53.89 at.%, Ru-37.40 at.%, and Pd+Rh-8.71 at.%. Established procedure through the fresh simulated DUPIC fuel was applied to the irradiated DUPIC fuel. Observed size of metallic precipitates were 2∼2.5 $\mu\textrm{m}$ and their compositions were Mo-47.34 at.%, Ru-46 at.%, and Pd+Rh-6.65 at.%. What are uncommon things for this experiment, special treatment for improving the conductivity was attempted to the specimen and the conditions of exact irradiation of electron beam to small metallic precipitate were suggested.

  • PDF

A Study on Microstructure and Mechanical Properties of Modified 9Cr-1Mo and 9Cr-0.5Mo-2W Steels for nuclear Power Plant (원자력용 개량 9Cr-1Mo 및 9Cr-0.5Mo-2W 강의 미세조직과 기계적 특성 연구)

  • Kim, Seong-Ho;Song, Byeong-Jun;Han, Chang-Seok;Guk, Il-Hyeon;Ryu, U-Seok
    • Korean Journal of Materials Research
    • /
    • v.9 no.11
    • /
    • pp.1137-1143
    • /
    • 1999
  • Microstructure and mechanical properties of Mod.9Cr-1Mo and W added 9Cr-0.5Mo2W steels were investigated for liquid metal reactor (LMR) heat exchange tube. The tempering temperatures at which cell structure was formed were $700^{\circ}C$ for Mod.9Cr-1Mo steel and $750^{\circ}C$ for W added 9Cr0.5Mo-2W steel. indicating the recovery of dislocation was delayed by the addition of W. 9Cr-0.5Mo-2W steel had the same kinds of precipitates with Mod.9Cr-1Mo steel, but the W was included in the precipitates in 9Cr-0.5Mo-2W steel. Micro-hardness and ultimate tensile strength of 9Cr-0.5Mo-2W steel were higher than those of Mod.9Cr-1Mo steel. The impact property of Mod.9Cr-1Mo steel was superior to that of 9Cr-0.5Mo-2W steel.

  • PDF