• Title/Summary/Keyword: Type-I error

Search Result 330, Processing Time 0.027 seconds

Statistical Issues in Genomic Cohort Studies (유전체 코호트 연구의 주요 통계학적 과제)

  • Park, So-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.40 no.2
    • /
    • pp.108-113
    • /
    • 2007
  • When conducting large-scale cohort studies, numerous statistical issues arise from the range of study design, data collection, data analysis and interpretation. In genomic cohort studies, these statistical problems become more complicated, which need to be carefully dealt with. Rapid technical advances in genomic studies produce enormous amount of data to be analyzed and traditional statistical methods are no longer sufficient to handle these data. In this paper, we reviewed several important statistical issues that occur frequently in large-scale genomic cohort studies, including measurement error and its relevant correction methods, cost-efficient design strategy for main cohort and validation studies, inflated Type I error, gene-gene and gene-environment interaction and time-varying hazard ratios. It is very important to employ appropriate statistical methods in order to make the best use of valuable cohort data and produce valid and reliable study results.

Design and Performance Evaluation of DC Generator Control System for Cortrolling Torque of Rotating Shaft (회전축의 정밀 토그 발생용 직류 발전기 제어장치의 설계 및 성능평가에 관한 연구)

  • Kim, G.S.;Kang, D.I.;Ahn, B.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.50-56
    • /
    • 1994
  • A DC generator control system was designed to control the torque of a rotating shaft precisely. The control system is composed of a strain gage type torque cell, a torque cell amplifier, a computer, a D/A converter, a error detector, a DC voltage amplifier and a resistor. The response test under unit step input and the dynamic stability test for the designed control system were carried out. It was confirmed that the settling time from the response test is about 4 s and the error from the dynamic stability test is less than 0.06% of rated output of torque cell. The designed control system may be used to control a DC generator which may be used to apply torque to a rotating shaft.

  • PDF

Analysis and Prediction of Prosodic Phrage Boundary (운율구 경계현상 분석 및 텍스트에서의 운율구 추출)

  • Kim, Sang-Hun;Seong, Cheol-Jae;Lee, Jung-Chul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.24-32
    • /
    • 1997
  • This study aims to describe, at one aspect, the relativity between syntactic structure and prosodic phrasing, and at the other, to establish a suitable phrasing pattern to produce more natural synthetic speech. To get meaningful results, all the word boundaries in the prosodic database were statistically analyzed, and assigned by the proper boundary type. The resulting 10 types of prosodic boundaries were classified into 3 types according to the strength of the breaks, which are zero, minor, and major break respectively. We have found out that the durational information was a main cue to determine the major prosodic boundary. Using the bigram and trigram of syntactic information, we predicted major and minor classification of boundary types. With brigram model, we obtained the correct major break prediction rates of 4.60%, 38.2%, the insertion error rates of 22.8%, 8.4% on each Test-I and Test-II text database respectively. With trigram mode, we also obtained the correct major break prediction rates of 58.3%, 42.8%, the insertion error rates of 30.8%, 42.8%, the insertion error rates of 30.8%, 11.8% on Test-I and Test-II text database respectively.

  • PDF

Inference Based on Generalized Doubly Type-II Hybrid Censored Sample from a Half Logistic Distribution

  • Lee, Kyeong-Jun;Park, Chan-Keun;Cho, Young-Seuk
    • Communications for Statistical Applications and Methods
    • /
    • v.18 no.5
    • /
    • pp.645-655
    • /
    • 2011
  • Chandrasekar et al. (2004) introduced a generalized Type-II hybrid censoring. In this paper, we propose generalized doubly Type-II hybrid censoring. In addition, this paper presents the statistical inference on the scale parameter for the half logistic distribution when samples are generalized doubly Type-II hybrid censoring. The approximate maximum likelihood(AMLE) method is developed to estimate the unknown parameter. The scale parameter is estimated by the AMLE method using two di erent Taylor series expansion types. We compar the AMLEs in the sense of the mean square error(MSE). The simulation procedure is repeated 10,000 times for the sample size n = 20; 30; 40 and various censored samples. The $AMLE_I$ is better than $AMLE_{II}$ in the sense of the MSE.

A Study of the Digital Phase-shift Resonant Converter to Reduce the conduction Loss and Stress of the Switching Device (스위칭 소자의 전도손실과 스트레스를 저감하기 위한 디지털 위상천이 공진형 컨버터에 관한 연구)

  • Shin, Dong-Ryul;Hwang, Young-Min;Kim, Dong-wan;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • Due to the development of information communication field, the interest of the SMPS(Switched Mode Power Supply) is increased. The size and weight of SMPS are decided by inductor, capacitor and transformer. Thus, the low loss converter which is operated in high speed switching is required. The resonant FB DC-DC converter is able to operate in high speed switching and apply to high power field because the switching loss is low. In this thesis, it is proposed to control strategy for constant output power of resonant FB DC-DC converter in variable input voltage. The proposed control system is a digital I-PD type control and apply to phase-shift resonant type controller. The output voltage tracks reference without steady state error in variable input voltage. The validity of proposed control strategy is verified from results of simulation and experiment.

The Analysis of Changma Structure using Radiosonde Observational Data from KEOP-2007: Part I. the Assessment of the Radiosonde Data (KEOP-2007 라디오존데 관측자료를 이용한 장마 특성 분석: Part I. 라디오존데 관측 자료 평가 분석)

  • Kim, Ki-Hoon;Kim, Yeon-Hee;Chang, Dong-Eon
    • Atmosphere
    • /
    • v.19 no.2
    • /
    • pp.213-226
    • /
    • 2009
  • In order to investigate the characteristics of Changma over the Korean peninsula, KEOP-2007 IOP (Intensive Observing Period) was conducted from 15 June 2007 to 15 July 2007. KEOP-2007 IOP is high spatial and temporal radiosonde observations (RAOB) which consisted of three special stations (Munsan, Haenam, and Ieodo) from National Institute of Meteorological Research, five operational stations (Sokcho, Baengnyeongdo, Pohang, Heuksando, and Gosan) from Korea Meteorological Administration (KMA), and two operational stations (Osan and Gwangju) from Korean Air Force (KAF) using four different types of radiosonde sensors. The error statistics of the sensor of radiosonde were investigated using quality control check. The minimum and maximum error frequency appears at the sensor of RS92-SGP and RS1524L respectively. The error frequency of DFM-06 tends to increase below 200 hPa but RS80-15L and RS1524L show vice versa. Especially, the error frequency of RS1524L tends to increase rapidly over 200 hPa. Systematic biases of radiosonde show warm biases in case of temperature and dry biases in case of relative humidity compared with ECMWF (European Center for Medium-Range Weather Forecast) analysis data and precipitable water vapor from GPS. The maximum and minimum values of systematic bias appear at the sensor of DFM-06 and RS92-SGP in case of temperature and RS80-15L and DFM-06 in case of relative humidity. The systematic warm and dry biases at all sensors tend to increase during daytime than nighttime because air temperature around sensor increases from the solar heating during daytime. Systematic biases of radiosonde are affected by the sensor type and the height of the sun but random errors are more correlated with the moisture conditions at each observation station.

Implementation of RFID Baseband system for Sensor Network (센서네트워크용 RFID Baseband 시스템 구현)

  • Lee, Doo Sung;Kim, Sun Hyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.4 no.4
    • /
    • pp.9-19
    • /
    • 2008
  • In this paper, it is studied anti-collision algorithm based on the transmission protocol for RFID baseband system of the lSO/IEC 18000-6 Type-C regulation and designed the baseband part of RFID reader system using FPGA. To compensate this weak point of the slot random aloha algorithm which must have a long time to be dumped before deciding an appropriate slot size according to the number of surrounding tag, we suggested how to apply Bit By Bit algorithm to be able to recognize the tag when the tag is clashing. The design of the baseband part in the RFID reader system is accomplish by use of the ISE9.1i and I made an experiment on it targeting Spartan2. Construction verification is measured each block through Logic Analyzer and I can verify it has no error. I also compared and analyzed the performance between proposed algorithm and past algorithm and verified the improvement of performance.

A Study on Scale Effects of the MAUP According to the Degree of Spatial Autocorrelation - Focused on LBSNS Data - (공간적 자기상관성의 정도에 따른 MAUP에서의 스케일 효과 연구 - LBSNS 데이터를 중심으로 -)

  • Lee, Young Min;Kwon, Pil;Yu, Ki Yun;Huh, Yong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.25-33
    • /
    • 2016
  • In order to visualize point based Location-Based Social Network Services(LBSNS) data on multi-scaled tile map effectively, it is necessary to apply tile-based clustering method. Then determinating reasonable numbers and size of tiles is required. However, there is no such criteria and the numbers and size of tiles are modified based on data type and the purpose of analysis. In other words, researchers' subjectivity is always involved in this type of study. This is when Modifiable Areal Unit Problem(MAUP) occurs, that affects the results of analysis. Among LBSNS, geotagged Twitter data were chosen to find the influence of MAUP in scale effects perspective. For this purpose, the degree of spatial autocorrelation using spatial error model was altered, and change of distributions was analyzed using Morna's I. As a result, positive spatial autocorrelation showed in the original data and the spatial autocorrelation was decreased as the value of spatial autoregressive coefficient was increasing. Therefore, the intensity of the spatial autocorrelation of Twitter data was adjusted to five levels, and for each level, nine different size of grid was created. For each level and different grid sizes, Moran's I was calculated. It was found that the spatial autocorrelation was increased when the aggregation level was being increased and decreased in a certainpoint. Another tendency was found that the scale effect of MAUP was decreased when the spatial autocorrelation was high.

Implementation of Various FIR Filters using Constrained Least Square Criterion (제한된 최소 자승 오차 기준에 의한 다양한 FIR 필터 구현)

  • Hong, Seung-Eok;Kim, Joong-Kyu
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.175-185
    • /
    • 1998
  • In this paper, we studied some design methodologies of typical FIR filters based on the peak-error constrained least square criterion which was first introducedd by Adams in 1991. This method is a mixed type of the classical least squared error method(LSM) and the so-called min-max error method (MMM). And by considering both the least squared error as well as the maximum error, the solution, i.e. the impulse response of the filter, can be found only when the restrictions on maximum gain, transition bandwidth, and the squared error are satisfied simultaneously under some trade-off conditions. We used the multiple exchange algorithms for optimization procedure and applied the design methodology to the cases of the multiband filter, the differentiator, and the Hilbert transformer by taking the balance of two design criteria into account. The results show that the peak-error constrained least weighted square error design method(PLEM) is superior in performance to the existing LSM and MMM from both the squared error and the maximum error standpoints. And it is verified that PLEM can be applied to not only the case of simple low pass filter, but also to various types of FIR filters.

  • PDF

Parameter Optimization of the Marine Gyrocompass Follow-up System (자이로콤파스 추종계통의 최적조정)

  • 이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.2
    • /
    • pp.49-58
    • /
    • 1981
  • One of the main purposes of the marine gyrocompass follow-up system is to preserve the sensitive part from the wandering error due to the frictional or torsional torque around the vertical axis. This error can be diminished through the rapid follow-up action, which minimizes the relative azimuthal angular displacement between the sensitive and follow-up parts and shortens the duration of the same displacement. But an excessive rapidity of the follow-up action would result in a sustained oscillation to the system. Therefore, to design a new type of the follow-up system, the theoretical annlysis of the problems concerned should be studied systematically by introducing the control theory. This paper suggest a concrete procedure for the optimal adjustment of the gyrocompass follow-up system, utilizing the mathematic model and the stability informations formerly investiaged by the author. For theoptimal determination of the adjustable paramfter K, the performance index(P.I.), ITSE(Intergral of the Time multiplied by the Squared Error) is proposed, namely, P.I. = $\int_{0}^{\infty} t \cdot e^{2}(t)dt$ where t is time and e(t) means control error. Then, the optimal parameter minimizing the performance index is calculated by means of Parseval's theorem and numerical computation, and the validity of the obtained optimal value of the parameter Ka is examined and confirmed through the simulations and experiments. By using, the proposed method, the optimal adjustment can be performed deterministically. But, this can not be expected in the conventional frequency domain analysis. While the Mps of the original system vary to the extent of from 0.98 to 46.27, Mp of the optimal system is evaluated as 1.1 which satisfies the generally accepted frequency domain specification.

  • PDF