• 제목/요약/키워드: Type of wires

검색결과 174건 처리시간 0.027초

SPM을 이용한 수소화된 p형 Si(100) 표면의 미세구조 제작 (Fabrication of Nanometer-scale Structure of Hydrogen-passivated p-type Si(100) Surface by SPM)

  • 김동식
    • 대한전자공학회논문지TE
    • /
    • 제39권2호
    • /
    • pp.29-33
    • /
    • 2002
  • 수소화된 p형 Si(100)표면에 대기중에서 작동하는 주사형 터널링 현미경(scanning tunneling microscopy-STM)을 이용하여 미세구조를 제작하였다. 시료의 표면처리는 HF 용액에 1분간 담가 수소화하였다. STM의 탐침은 백금합금을 역학적인 방법으로 45$^{\circ}$로 잘라서 사용하였다. STM의 바이어스 전압을 변화시켜가며 미세구조를 제작하였다. 최적의 미세구조 선폭은 30 nm이고 이 때의 바이어스 전압은 1.7V, 터널링 전류는 1nA였다.

R&D trends of high current REBCO conductor

  • Oh, Sang-Soo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권1호
    • /
    • pp.1-7
    • /
    • 2022
  • So far, large-scale scientific devices such as nuclear fusion tokamaks and high energy circular accelerators were constructed using high-current conductors made of metallic superconducting wires. Recently, as REBCO superconducting wires usable in high magnetic fields have been developed by several companies, researchesto apply high current cable type REBCO conductors to next-generation large superconducting magnets were also started. High critical currents of several kA or more in high magnetic fields have been successfully demonstrated on test samples of REBCO cable conductors by several research groups. In this review article, the main features and properties of the representative high current REBCO conductors such as CORC(Conductor On Round Core), TSTC(Twisted Stacked-Tape Cable) and RACC(Roebel-Assembled Coated Conductor), which are currently being developed at abroad are briefly introduced. Research activities of high-current density REBCO MHOS(Multi HTS layers on One Substrate) conductor at KERI, whose structure is different from other cable type REBCO conductors are also shortly introduced.

접착방법 및 multistranded wire의 종류에 따른 접착식 보정장치의 전단접착강도에 관한 연구 (A Study of shear bond strength of bonded retainer according to the bonding method and type of wires)

  • 이형철;손우성
    • 대한치과교정학회지
    • /
    • 제32권2호통권91호
    • /
    • pp.143-153
    • /
    • 2002
  • 콤포지트와 여러가닥 강선을 사용하여 제작된 접착식 보정장치는 심미적이며, 효과적인 보정장치라 할 수 있다. 이 연구는 접착식 보정장치의 전단접착강도를 측정하고, 접착식 보정장치의 제작 시 사용하는 여러가닥 강선 및 접착방법의 이상적인 조합을 제시하기 위해 디자인되었다. 교정치료를 위해 발거한 건전한 상하악 소구치 160개를 사용하여 80개의 시편을 제작하였다. 접착면적 및 강선의 길이, 콤포지트의 두께를 동일화하고, 직접접착 및 간접접착의 방법으로 여러가닥 강선을 접착하여 접착식 보정장치를 제작하였다. 만능시험기를 사용하여 각 시편에서의 전단접착강도 및 강선의 탈락시까지의 신장량을 측정하여, 다음과 같은 결론을 얻었다. 1. 6가닥, 0.0155인치의 강선에서 가장 큰 최대 접착강도를 보이고, 3가닥, 0.0195인치의 강선에서 가장 작은 최대 접착강도를 보였는데, 그 차이는 유의할 만큼 크지 않았다(p<0.05). 즉 강선의 직경 및 가닥수는 접착강도와 큰 연관성이 없다. 2. 3가닥, 0.015인치의 강선에서 가장 큰 신장량을 보여 주었고, 3가닥, 0.0195인치 강선에서 가장 작은 신장량을 보여주었다(p<0.05). 강선의 직경이 작을수록 신장량은 크게 나타났으나, 강선의 가닥수는 신장량과 큰 연관성이 없다. 3. 두 가지 접착방법의 비교에서 간접 접착술식을 사용했을 때 더 큰 접착강도 및 신장량을 보여 주었고, 통계적으로 유의한 차이를 나타냈다(p<0.05).

가동 자석형 3 축 구동 엑츄에이터 개발 (Development of 3-axis Moving Magnet Type Actuator)

  • 송명규;허영준;박노철;유정훈;박영필
    • 정보저장시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.191-195
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to be equipped with 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added a tilt mechanism to the 2-axis moving magnet actuator which is designed in previous research. Addition of the tilt mechanism cuts down the focus sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

가동 자석형 3 축 구동 엑츄에이터 (3-axis Moving Magnet Type Actuator)

  • 허영준;송명규;박노철;유정훈;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1033-1036
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to equip 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added tilting mechanism to 2-axis moving magnet actuator which is designed in previous research. Addition of the tilting mechanism cuts down the focusing sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

60kgf/$\textrm{mm}^2$급 C-MO계 와이어를 사용한 서브머지드 아크 용접금속 인성 및 작업성에 미치는 플럭스 조성의 영향 (Effect of Flux Composition on Weld Metal Toughness and Workability in Submerged Aye Welding with 60kgf/$\textrm{mm}^2$ Grade C-Mo Type Wires)

  • 방국수;안영호
    • Journal of Welding and Joining
    • /
    • 제14권6호
    • /
    • pp.93-100
    • /
    • 1996
  • Effect of a flux composition on weld metal toughness in submerged arc welding with 60kgf/$\textrm{mm}^2$ grade C-Mo type wires was investigated and interpreted in terms of weld metal microstructure and hardenability. Flux workability was also studied by characterizing a weld bead profile. Compared to other weld metals, .weld metal used alumina basic flux with nickel showed lowest oxygen content, highest hardenability and the most acicular ferrite. The highest impact toughness of that weld metal, however, was attributed to the tough matrix due to the nickel rather than to the larger amount of acicular ferrite. Manganese silicate flux had better workability than alumina basic flux, showing broader welding conditions resulting in a depth-to-width ratio of 0.5. The composition of oxides in the weld metal was dependent on the flux composition, showing MnO-SiO$_2$-TiO in manganese silicate flux and MnO-SiO$_2$-Al$_2$O$_3$-TiO in alumina basic flux. MnO-SiO$_2$composition in both oxides was similar to a tephroite.

  • PDF

국산(國産)스테인레스강선계(鋼線系) 교정용선재(矯正用線材)의 개발(開發)과 물리적(物理的) 성질(性質)에 관(關)한 연구(硏究) (A STUDY ON DEVELOPMENT AND PHYSICAL PROPERTIES OF STAINLESS STEEL ORTHODONTIC WIRES MADE IN KOREA)

  • 성재현;권오원;경희문;이기대
    • 대한치과교정학회지
    • /
    • 제19권2호
    • /
    • pp.7-24
    • /
    • 1989
  • The physical properties of seven sizes of control groups and experimental group in stainless steel orthodontic wires were studied in tension, hardness, bending, torsion and observation of microstructure. The wires (0.40-0.90mm dia.) of round type were tested in the as-received condition. The wires of control groups were TRU-CHROME and REMANIUM, and experimental group was SK wire which was developed by ourselves and made in Korea. The results were as follows; 1. The chemical compositions of control groups and experimental group were austenite stainless steel wires of SOS 304. 2. Higher values of tensile and yield strength in tension were control group I, experimental group, control group II. Maximum tensile and yield strength of experimental group were $203.63{\pm}1.41kg/mm^2$ in 0.70mm diameter and $148.96{\pm}4.88kg/mm^2$ in 0.60mm diameter, and maximum elongation was $5.20{\pm}0.57%$ in 0.45mm diameter. 3. Hardness values of experimental group were similar to control groups. Maximum hardness values were $596.2{\pm}13.66Hv$ in 0.45mm diameter wire of control group I, $590.5{\pm}20.08Hv$ in 0.50mm diameter wire of control group II, and $563.6{\pm}5.35Hv$ in 0.70mm diameter wire of experimental group. 4. Torsion properties of experimental group were similar to control group I and more than control group II. Maximum torsion cycles were $31.8{\pm}2.48$ in 0.45mm diameter of control group I, $17.4{\pm}4.84$ in 0.60mm diameter of control group II, and $24.6{\pm}3.04$ in 0.45mm diameter of experimental group. 5. Maximum bending cycles of experimental group were smaller than control groups. Maximum bending cycles were $9.00{\pm}0.00$ in 0.50mm diameter wire of control group I, $10.0{\pm}0.82$ in 0.40mm diameter wire of control group II, and $8.0{\pm}1.26$ in 0.50mm diameter wire of experimental group. 6. Microstructures of experimental and control groups co-existed with martensited austenite structure and elongated austenite structure. 7. The direction of wire fracture was propagated parallel to torsion direction typically and there was no probability showing wire fracture at inclusions and surface scratches. 8. The type of wire fracture was brittle fracture at initiation site and ductile fracture at core.

  • PDF

수술용 강선에 대한 인장력 측정센서의 설계 및 특성평가 (Design and Evaluation of the Tension Sensor for Surgical Steel Wires)

  • 주진원;이봉식
    • 대한기계학회논문집A
    • /
    • 제21권2호
    • /
    • pp.261-271
    • /
    • 1997
  • This paper presents the design process and characteristic test results of tension sensors for measuring the ultimate tension forces of surgical wires. Three types of sensor were designed and tested for calibration. The first two types which transfer the wire tension to the sensing element by direct contact have too much hysterisis errors due to the firctional effect. This error can be considerably reduced in the modified structure, where a cover and a loading button is used to transfer force and moment to the sensing element. The strains predicted by theoretical equations agree well with those by finite element calculations neglecting friction and the strains by finite element analysis considering friction are in good agreement with those measured by four strain gages. The modified ring type tension sensor developed in this paper is expected to be useful for measuring the tension of surgical wires with nonlinearity of 1.31%FS, hysterisis of 5.74%FS and repeatability of 0.19%FS.

C형 경골천정 골절에 대한 일리자로브 외고정술 (ILIZAROV FIXATION FOR THE TYPE C TIBIAL PLAFOND FRACTURES)

  • 조헌오;곽경덕;조성도;김병용;오장호
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.51-58
    • /
    • 1997
  • The purpose of this study is to evalute the efficacy af the Ilizarov external fixation for the surgical treatment. of the tibial plafond fractures. We reviewed retrospectively fourteen cases of tibial plafond fractures with moderate to severe soft. tissue damage, which were fixed with Ilizarov external fixator. Using the AO Muler classification, there were four Type C1 fractures, six Type C2 and four Type C3. In most, of the cases, the ankles were operated on with other associated fractures within a few days after injury. We reduced the fracture indirectly by soft issue taxis and fixed externally across the ankle joint. using the circular external fixator with tensioned wires and ankle hinge. In cases of inadequate closed reduction, we applied limited open reduction and internal fixation. Range of motion exercise began immediately. Postoperative follow-up averaged fourteen months (ranges, 8-30 months). Overall clinical results rated good or excellent in 7 cases, fair in 4 and poor in 3. There were three cases of pin tract infection which were resolved with short-term antibiotics and local care; one delayed wound closure in a patient. whose fracture was associated with Type III open wound; one wound slough in a patient associated with Type II open wound, which was closed later by skin graft; and one osteoarthritis. From this review, we concluded that cross-ankle circular external fixation with tensioned wires with or without. limited open reduction is a reasonable alternative for the treatment of the tibial plafond fractures with severe soft tissue damage.

  • PDF

Mechanical Properties and Comparisons of Cerclage Wires of Various Diameters in Different Knot Methods

  • Jang, Aram;Kim, Jieyoo;Park, Ji-Hun;Yoon, Eunchae;Lee, Dongbin;Lee, Jae-Hoon
    • 한국임상수의학회지
    • /
    • 제39권4호
    • /
    • pp.149-155
    • /
    • 2022
  • The aim of this study was to compare the mechanical properties of 0.6 and 0.8 mm cerclage wires with the 1.0 mm cerclage wire in the twist, single-loop, double-loop, double-wrap, and loop/twist knot methods. Six stainless steel cerclage wires of various diameters in different knot methods were tied round a customized jig mounted on a load testing machine. The initial tension, initial stiffness, and yield load were evaluated. The failure mode of each cerclage was observed. For each wire size, the double-loop, double-wrap, and loop/twist knots showed significantly greater initial stiffness, and yield load than those seen with twist and single-loop knots. The single-loop knot showed the least initial stiffness regardless of the diameter. As the cerclage wire diameter increased, the cerclage tended to show significantly greater initial stiffness, and yield load. Failure modes varied depending on the knot configurations. Single-loop knots of smaller-diameter wires less than 1 mm had similar or lower initial tension, initial stiffness, and yield load than a twist knot. Owing to the variance in mechanical properties, the clinical application of the knot type should depend on the diameter of the cerclage wire.