• 제목/요약/키워드: Type of Installation

검색결과 1,526건 처리시간 0.027초

부분방전원에 의해 중첩된 초음파신호의 정량적분석 (The Quantitative Analysis of the Superposed Ultrasonic Signal by PD Sources in a Transformer)

  • 송현석;구교선;이동준;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.163-166
    • /
    • 2001
  • In this paper, the superposition of ultrasonic signals which were generated by multi-source in a transformer was presented. For analysis of ultrasonic superposition, V$_{peak-peak}$ and pulse number of ultra-sonic signal were used. As a result, the wave form of ultrasonic superposition was classified into three types ; First type was the wave form whose V$_{peak-peak}$ was increased by the superposition of each signal's V$_{peak-peak}$. Second type was wave form whose V$_{peak-peak}$ was decreased by the superposition of each signal's V$_{peak-peak}$. And the other type was wave form whose peals were two or mere. And V$_{peak-peak}$ of superposed ultrasonic wave wads mostlv increased or decreased and pulse number of supe게osed u1trasonic wave was mostly increased.y increased.

  • PDF

접지임피던스의 변동이 최소가 되는 동축형 탄소접지전극의 길이의 산정 (Determination of the Length of Coaxial Type Carbon Grounding Electrode to Minimize the Fluctuation of Grounding Impedance)

  • 이강수;김종호;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.164-170
    • /
    • 2010
  • For the surge currents like lightning or ground fault currents containing high frequency components which cause the electromagnetic interferences for the electronic devices and communication equipment, the grounding impedances give the significantly composite characteristics which are dependent on the frequency of surge currents. In this paper, the analytical model and method for determining the optimal length of the newly developed coaxial type carbon ground electrode which has a little fluctuation in grounding impedance with frequency. The length of minimizing the fluctuation of grounding impedance by changing frequency from 100[Hz] to 1[MHz] was determined, and the validity of this proposed method was confirmed by comparing with the simulated and measured data.

대학생의 선호색과 자신의 이미지색에 관한 연구 (A Study on the Color Preference and the Personal Color of University Students)

  • 정미란;안옥희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.163-166
    • /
    • 2005
  • Colors are in the inseparable relation ia the all parts of human life. The color influences not only our psychological and physiological aspects, but also our way of behavior. The purpose of this study was to investigate the color preference and the personal color of 100 university students. As results of researching current university students color preference when we compare it with pre-studied results, it shows some differences. In pre-studied, the blue and black marked high degree, but for recent students, it has appeared that warm color is highly preferred. Also warm color has shown as the personal color. There were significant differences in the relation between the blood type and color preference. It appears that the blood type A and B were preferred to cold color while the blood type of B and AB were preferred to warm color.

  • PDF

A Study on the Detent Torque Reduction of Claw Pole Permanent Magnet Type Motor

  • Jung, Dae-Sung;Lee, Ju;Lee, Sang-Taek
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.125-132
    • /
    • 2013
  • This paper has done a three-dimensional FEM analysis of the PM claw pole stepping motor. As magnetization happens in the z-axis, which does not have a constant value, three-dimensional FEM analysis is necessary for characteristic analysis of PM claw pole stepping motors. Because it is a type of permanent magnet motor, the PM claw pole stepping motor naturally has a detent torque. This torque is known to show negative effects on motor performance. To improve motor performance, reducing the detent torque is very important during the motor design. This paper applied DOE for optimization of stator pole design of the motor. Also, we compared motor performance by applying a different type of rotor shape, dividing the permanent magnet. To verify the simulation results, an experiment was done.

삼파장 적외선식 불꽃감지기의 자가진단 회로 개발 (A Study on Signal Circuit of the Self Diagnosis Type Triple Infrared Flame Detector)

  • 송현선;이의용
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.69-74
    • /
    • 2013
  • There is needed the triple pyroelectric Infrared flame detector to really recognize problem, for the prevention and early suppression of fire. This system recognizes the characteristics of fire sources in various type and is communicated the message to the operators. Therefore, the prevention and early suppression of fire is available. Especially this paper focuss on development of the self diagnosis type flame detector for preventing malfunction comparing of basic and detected values.

A Speed Control of Stepping Motor Using a Self-Tuning Regulator

  • Kim, Young-Tae;Kim, Sei-Yoon
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.69-75
    • /
    • 2009
  • In this paper, a self-tuning regulator for a speed control of a permanent magnet type stepping motor is proposed. The self-tuning theory provides a nonlinear modeling of a stepping motor drive system and can provide the controller with information regarding the reference variation and parameter variation of the stepping motor through the on-line estimation. The proposed self-tuning regulator organize the positive feedback loop and IP(Integral-Proportional) type. Therefore, the proposed self-tuning regulator has a robust control capabilities during dynamic operation. The availability of the proposed controller is verified through experimental results.

전원단 및 부하단 사고에 따른 DC 리액터형 고온초전도 전류제한기 동작특성 (Operational Characteristics of DC Reactor Type SFCL for Accident of Both Power Source Side and Load Side)

  • 이수원;임성훈
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.140-145
    • /
    • 2004
  • 본 논문은 사이리스터 또는 GTO사이리스터를 이용한 변형된 DC리액터형 고온초전도 전류제한기의 부하단 사고시 사고전류 제한동작 뿐아니라 전원단 사고로 인해 부하로의 전력공급이 중단되었을 경우, 평상시 초전도코일에 저장된 에너지를 이용하여 부하에 연속적인 전력을 공급할 수 있는 기능을 수행할 수 있음을 분석하였다. 시뮬레이션 결과는 이론적인 분석과 일치함을 나타내었다.

영전압 방전이 가능한 새로운 방식의 2차전지 충방전기 (New Secondary Battery Charger/Discharger Available for Zero Voltage Discharge)

  • 정대택;채수용;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.62-74
    • /
    • 2012
  • This paper proposes a new secondary battery charger/discharger available for zero voltage discharge which is used for test equipments and formation process. The proposed system is a switching type converter, and thus the system is high efficiency and more compact as compared with linear type charger/discharger. Conventional switching type charger/discharger can not discharge secondary batteries to zero voltage because of voltage drops in the switching elements and long distributing line(typically 10m). However, the proposed system is able to discharge the battery to zero voltage in constant current mode regardless of the voltage drops. In this paper, we analyze the proposed charger/discharger and the validity of the system is verified by simulation and experiment.

대용량 몰드변압기 정밀절연진단 결과 고찰 (A study of Insulation Diagnosis for Large-Capacity Mold Transformer)

  • 이은춘;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.75-81
    • /
    • 2014
  • When the large-capacity Mold type Transformer was passed through rain, after it was dried and it's parts were changed, Insulation Diagnosis was made to evaluate the condition of it and decide to recharge. Using the evaluation of Insulation Diagnosis, the urgent decision-making for recharge made blackout time minimum. In this study, it was considered that Insulation Diagnosis for the large-capacity Mold type Transformer is applied to decision-making for reuse of high voltage electric power equipment by analysis of the case study.

디지털 신호 처리 기반 저압 차단기용 전자식 계전기 개발 (A Development of Electronic Type Relay for Low Voltage Circuit Breaker based on Digital Signal Processing)

  • 박병철;손종만;송성근;신중린
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.81-88
    • /
    • 2013
  • A low voltage circuit breaker protects electrical equipments from over current and short faults of system by cutting the power supply. The breaker use a thermal magnetic type trip device from the past. In recent years, electronic type relays are applied due to useful functions and services. The purpose of this development is full digitalizing of relay functions of a low voltage breaker. It includes separation of current sensor from current transformer, digital signal processing, high speed relaying, and voltage measuring for power meter. The suggestions are tested and implemented by making prototype and testing its all relay functions.