• Title/Summary/Keyword: Type of Installation

Search Result 1,522, Processing Time 0.026 seconds

The Blind Modeling of Horizontal Blind Using the RADIANCE Program (RADIANCE프로그램을 이용한 블라인드 모델링)

  • 정근영;최안섭
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.91-95
    • /
    • 2002
  • This study is using the RADIANCE lighting simulation tool to determine the transmittance where the horizontal blind is installed. The transmittance is applied to DayDim program which is a lighting calculation and analysis tool. Parameters such as clear sky type, seasonal changes(the summer solstice), altitude, azimuth and horizontal blind angle at a 0$^{\circ}$, 45$^{\circ}$, 90$^{\circ}$ were considered. The simulation results present that measured directional transmittances have different values according to each directional property of the horizontal blind.

  • PDF

Seismic Response Analysis of Dome-Shaped Large Spatial Structures According to TMD Installation (TMD 설치에 따른 돔 형상 대공간 구조물의 지진응답분석)

  • Ku, Seung-Yeon;Yoo, Sang-Ho;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.4
    • /
    • pp.27-34
    • /
    • 2023
  • In this study, the seismic response characteristics of the three analysis model with or without TMD were investigated to find out the effective dome shape. The three analysis models are rib type, lattice type and geodesic type dome structure composed of space frame. The maximum vertical and horizontal displacements were evaluated at 1/4 point of the span by applying the resonance harmonic load and historical earthquake loads (El Centro, Kobe, Northridge earthquakes). The study of the effective TMD installation position for the dome structure shows that seismic response control was effective when eight TMDs were installed in all types of analysis model. The investigation of the efficiency of TMD according to dome shape presents that lattice dome and geodesic dome show excellent control performance, while rib dome shows different control performance depending on the historical seismic loads. Therefore, lattice and geodesic types are desirable for seismic response reduction using TMD compared to rib type.

Comparative Analysis on luminous efficiency of bulb type LED lamps using both photogoniometer and integrating shpere (절대광속 측정기와 적분구를 이용한 벌브타입 LED 램프의 광효율 측정분석)

  • Jeon, Sang-Kyoo;Na, Nong-Hyuk;Kim, Do-Hwan;Lee, Hyun-Young;Cho, Mee-Ryoung;Choi, Yong-Woon;Yang, Seong-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.149-151
    • /
    • 2009
  • This paper gives a comparative analysis on the luminous efficiency of the bulb type LED lamps. we compare and analyze the measurement values bulb type LED lamps using both photogoniometer and integrating sphere. The volt and watt of one 1map are 220 V and 7 W, respectively. The volt and watt of other one are 100 V and 5.3 W, respectively. the values of those were 79.7 1m/W and 76.9 1m/W in the integrating sphere, respectively. Similarly, the values of those were 80.2 1m/W and 79.3 1m/W on the photogoniometer, respectively. As a result, the value of luminous efficiency can be measured using either integrating sphere or absolute goniometer regardless of the difference in case of bulb type LED lamps.

  • PDF

Analysis on Current Limiting and Recovery Characteristics of a Trigger Type SFCL as the Composition of the Contact (트리거형 초전도한류기의 접점구성에 따른 전류제한 및 회복특성 분석)

  • Choi, Jong-Soo;Kim, Myoung-Hoo;You, Il-Kyoung;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.159-164
    • /
    • 2010
  • We experiment to analyze on current limiting and recovery characteristics of trigger type SFCL as the composition of the contact. Generally, some superconductor of SFCL is relatively largely loaded due to limit the fault current by oneself and recovery time is affected until the fault cleared. However, in the fault, the proposal trigger type SFCL transfer the fault current to current limiting reactor(CLR) using power switch so it could reduce the recovery time and load of the superconductor. However, because of applying the additional power switches, that could generate some power loss. Therefore, to solve this problem, we proposed the composition method of the double contact for a trigger type SFCL and analyzed on current limiting and recovery characteristics for ones.

Analysis on Fault Current Limiting Characteristics Dependent on Air-Gap in a Flux-Lock Type SFCL with parallel connection of two coils (병렬연결된 두 코일을 가진 자속구속형 초전도 전류제한기의 공극유무에 따른 전류제한 특성 분석)

  • Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • Air-gap was introduced to suppress the saturation of the iron core comprising the flux-lock type superconducting fault current limiter (SFCL) with parallel connection of two coils. However, the air-gap makes the impedance of this SFCL decreased and can result in unusefulness of the SFCL. To analyze the current limiting characteristics of the SFCL with the air-gap, the experimental circuit for short-circuit test was constructed. Through the comparison with the current limiting characteristics of the SFCL without air-gap, the merit and the demerit of the flux-lock type SFCL with the air-gap were discussed.

High-Efficiency Converter for Automotive Headlamp Using New H-type Snubber (새로운 H-type 스너버를 이용한 차량 헤드램프용 고효율 컨버터)

  • Kim, Sung-Joo;Kim, Sun-Pil;Jung, Tae-Uk;Park, Sung-Jun;Park, Seong-Mi
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.65-72
    • /
    • 2015
  • Recently, LED light has been increasingly adopted for vehicles in both domestic and foreign automotive markets, while a variety of LED lights have been developed to be used particularly for headlamps. In this paper, we propose an H-type resonant snubber circuit topology for high efficiency of vehicle LDM (LED Driver Module) and realized LDM functions for vehicle headlamp by designing high-efficiency convertors. In addition, this study reduced the financial burden by configuring the system to control the whole with micom except for the use of individual dedicated chips to drive LED for high and low beam. In order to verify the validity of the proposed H-type resonant snubber capable of soft switching, simulations were performed using PSIM. As a result, the validity was experimentally verified by creating a prototype. Moreover, in order to actually attach the headlamp, the performance of the proposed convertor was confirmed by designing LDM to the limited size. Communications between the headlamp and higher controller were realized using LIN(Local Interconnect Network).

The Characteristic of Hydrogen Generation on the Structure of Plasma Reactor Using the Streamer Discharge in the Water (수중 스트리머 방전용 플라즈마 반응기 구조에서 수소발생 특성)

  • Park, Jae-Youn;Kim, Jong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.37-42
    • /
    • 2006
  • The effect of arc like streamer discharge is investigated on the hydrogen generation using the multineedle-plate electrode geometry plasma realtor(MPER) and the needle-plate electrode geometry plasma reactor(NPER). In order to restrict waves at the water surface when the high voltage applied, two kinds of the insulator such as the rectangular mesh or the hole mesh type are installed under the water surface. The discharge assistant of the two type(the saw type and the $TiO_2$ pellet type) was placed under the water surface to investigate the effect of the water surface conditions. The experimental results are compared in case of the reactor with and without the discharge assistant on the water surface.

The Design of an Electronic Ballast by Single Switching Type (단일 스위칭 방식의 전자식 안정기 설계)

  • 노재엽;김순기;이준호;이진우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.271-274
    • /
    • 2002
  • 본 논문에서는 Class E zero-current-switching (ZCS) 인버터를 이용하여 단일 스위치로서 램프를 점등하는 타여자 방식의 전자식 안정기를 제안하였다. 이론을 통해 각 파라미터를 계산하고, PSpice 시뮬레이션을 통하여 안정상태의 램프출력을 예측하였다. 또한, MOSFET의 전압 스트레스를 고려한 스너버 회로를 구성하여 스위칭 서지전압의 발생을 억제하였으며, 실제 전자식 안정기를 제작하여 전기적 특성을 살펴보았다.

  • PDF

Grounding System Design of GIS type AC Substation using Personal Computer (P.C.에 의한 GIS형 AC Substation의 접지계 설계)

  • Yim, Han-Suck;Kim, Wang
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-53
    • /
    • 1990
  • GIS(Gas-Insulated Switchgear)형 옥내변전소에 있어서 접지계의 구성은 접지도체를 포설할 수 있는 면적이 협소하기 때문에 특별한 설계방법이 요구된다. 본 논문에서는 접지망의 전위해석과 축소형 변전소의 접지계 설계기법을 제시하였고, 아울러 컴퓨터 시뮬레이션을 위한 프로그램을 작성하고 그 시뮬레이션 결과를 측정치와 비교하여 프로그램의 타당성을 입증하였다.

  • PDF

An Simulation of Moving-Picture Noise for the PDP (PDP의 동화상 노이즈 시뮬레이션)

  • Ryeom, Jeong-Duk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.189-191
    • /
    • 2008
  • Hold-type display의 동화상 인식 원리를 이용하여 인간의 시각특성을 고려한 동화상 노이즈 컴퓨터 시뮬레이터를 개발하였다. 그리고 이 시뮬레이터를 이용하여 PDP의 동화상 노이즈인 의사윤곽 노이즈의 서브필드 배열과 속도 의존성에 대해 실험하였다. 실험 결과 기존의 서브필드 배열 방식은 의사윤곽 노이즈를 저감시킬 수가 있으나 화상의 이동속도가 빠를수록 노이즈가 증가하는 것을 알 수 있어 근본적인 대책이 될 수 없다는 것을 알았다.

  • PDF