• Title/Summary/Keyword: Type conversion

Search Result 1,376, Processing Time 0.022 seconds

Frequency Miner Characteristics for Direct Conversion Receiver (직접변환수신기에 적합한 주파수 혼합기의 특성분석)

  • 박필재;유현규;조한진
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.154-157
    • /
    • 2000
  • One of the problems using DCR(Direct Conversion Receiver) type architecture are DC offset, Poor channel selectivity. APDP(Anti Parallel Diode Pair) can be mood candidate for the DCR frequency mixer due to its inherent 2nd harmonic suppression. APDP shows good IP2 and DC suppression. This paper describes single APDP LO power characteristics, IP2, and receiver structure utilizing APDP frequency mixer.

  • PDF

Effect of surface etching and ultrafine fibers on sound absorption characteristics

  • Lee, Yun-Eung;Seon, Choe-Hwa;Su, Baek-Mun;Hwan, Ju-Chang
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1998.10a
    • /
    • pp.406-409
    • /
    • 1998
  • Sound absorbing materials are divided into several types according to the appearances and the characteristics. Basic mechanism of sound absorption in various sound absorbing materials is the conversion of sound energy into hat energy. Here the important elements which govern by the conversion from sound into heat depend on the type of materials. (omitted)

  • PDF

Conversion Equation dB (Rion) to PPV(cm/sec) (dB과 cm/sec간의 환산실험식)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.9 no.2
    • /
    • pp.3-7
    • /
    • 1991
  • The Problem of vibration Inflence to housing Construction fields has arised at the begining of 1970, at That time I used Lion(VM -l2B) which recorded only dB Demension. On the 1980's I have been used lnstantel made blastemate(DS-477), modern Instrument for measuring speed, Acc, frequency and placement. but The most of Jobsite used Lion I Carried out the empirical equation of conversion dB to cm /sec as follows. Single free face : dB = 140PPV + 30 double free face : dB = 143PPV + 20 Above equation Could apply on Rock type 3(soft rock)

  • PDF

A Study for Fixed Type Wave Energy Conversion Device with Oscillating Water Column (고정식 진동수주형 파력발전기에 관한 실험적 연구)

  • 김성근;박노식;박인규
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.136-145
    • /
    • 1996
  • The theory is based on two thermodynamic equations for the air mass in the air column and bydrodynamic equation for the relation between the response of the air in the water column and the incident wave. The numerical model is experimented in a two dimensional water tank and the caisson model with sloped front wall is tested in the large towing tank.

  • PDF

NORAD TLE CONVERSION FROM OSCULATING ORBITAL ELEMENT

  • Lee, Byoung-Sun
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.395-402
    • /
    • 2002
  • The NORAD type Two Line Element (TLE) was obtained from the osculating orbital elements by an iterative approximation procedure. The mathematical model was presented and computer program was developed for the conversion. The osculating orbital elements of the KOMPSAT-1 were converted into the NORAD TLE. Then the effect of the SGP4 atmospheric drag coefficient ($B^*$) was analyzed by comparison of the orbit propagation results with different $B^*$ values.

A Study on the introduction of the outpatient and inpatient conversion factors in the 2020 Physician Fee Contract (외래⦁입원 환산지수에 기초한 2020년도 환산지수 산출 연구)

  • O, Dongil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.183-194
    • /
    • 2021
  • In this study, the conversion factor for 2020 is estimated based on an outpatient and inpatient conversion factor separation model developed from SGR and AR by using actual medical expense data. In addition, a policy plan is proposed to calculate the values of single and multiple conversion factors for each type of medical expense, and to effectively use the conversion factor separation model as one of the means to establish a medical delivery system. The major results are as follows. First, at r=0.1, the rate of adjustment in the hospital single conversion index in 2020 was 2.0%, and the outpatient and hospitalization conversion rates for hospitals were 2.2% and 2.3%, respectively. In addition, a combination of outpatient and inpatient conversion factors can be used for the adjustment. Second, as a measure to establish a medical delivery system, instead of adjusting the addition rate, a method of interlocking the addition rate and the conversion factor is proposed. Third, it is necessary to develop a model that enables target management of volumes, in addition to the outpatient conversion factor, the inpatient conversion factor, and the adjustment coefficient.

The Estimation for Extracted Wave Power of an Ocean Wave Energy Conversion Device of the Oscillating Water Column Type (진동수주형 파력발전기의 흡수파력 추정에 관한 연구)

  • Kim, Seoung-Gun;Park, Myung-Kyu;,
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.31-38
    • /
    • 1991
  • Due to the structural complexity and the mutual interference of "water columns", the estimations of absorption power for a large wave energy conversion devices of flosting type in ocean could not achieve the desired results. Thus, in this paper the authors will propose a new methodology based on the three dimensional source ditribution method. We distributed the source to the device and the thin & light plate in "water column", And from the behaviour of this plated, the power and the pressure in water column are calculated. But, yet method should be proved to be valid by experiment.

  • PDF

Cure Kinetics of a Bisphenol-A Type Vinyl-Ester Resin Using Non-Isothermal DSC

  • Ahn, WonSool
    • Elastomers and Composites
    • /
    • v.53 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • In the current research, the curing kinetics of a mixture system consisting of a Bisphenol-A type vinyl ester resin and styrene monomer was studied. Methylethylketone peroxide and cobalt octoate were used as the polymerization initiator and accelerator respectively. Thermograms with several different heating rates were obtained using non-isothermal differential scanning calorimetry. Activation energy values analyzed by the Flynn-Wall-Ozawa isoconversional method showed a three-step change with conversion ${\alpha}$: a slight decrease initially for ${\alpha}$ < 0.1, a constant value of 47.9 kJ/mol in the range 0.1 < ${\alpha}$ < 0.7, and a slow increase for 0.7 < ${\alpha}$. When assuming a constant activation energy of 47.9 kJ/mol, an autocatalytic model of the Sestak-Berggren equation was considered as the proper mathematical model of the conversion function, indicating an overall order of 1.2.

Mode conversion in nondestructive nonlinear acoustic method for defect detection in a layer-structured material

  • Roh Heui-Seol;Yoon Suk Wang
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.219-222
    • /
    • 2001
  • Nondestructive nonlinear acoustic method in two dimensions is suggested as a useful tool for detecting defects in a composite layer-structured material. Spectrum level changes in fundamental and harmonic frequencies are observed in the presence of a layer type defect compared with in the absence of such a defect. It is proposed in this study that such spectrum changes we due to the mode conversion. The layer type defect makes different normal modes due to different boundary conditions in the thickness direction for the Lamb waves propagating in a layer-structured material. Specifically, the normal mode with the fundamental frequency in the case of the water-layer gap is converted to the normal mode with the second harmonic frequency in the case of the air-layer gap.

  • PDF

High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge (도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성)

  • 문재덕;이근택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF