• Title/Summary/Keyword: Type V

Search Result 5,529, Processing Time 0.032 seconds

Analysis of Correlation between Compressive Strength, Void Ratio and Chloride Diffusion Coefficient of Concrete Using Various Kinds of Cement (시멘트의 종류별 콘크리트외 강도 및 공극률과 염화물 확산계수의 상관관계 분석)

  • Yoon Eui-Sik;Lee Taek-Woo;Park Seung-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.735-742
    • /
    • 2005
  • The purpose of this study was to evaluate the salt water resistance of concrete depending on various types of cement. In this regard, 5 types of concrete were selected and their strength, void ratio and chloride ion diffusion characteristics were tested, and mutual correlation were analyzed. From the test results, the compressive strength and void ratio of concrete which using Type V cement was as good as Type I cement at long-term ages but the chloride diffusion coefficient of Type V cement was larger than Type I cement. And the concrete replacing some portion of the Type I cement with fly ash was superior in the cases of compressive strength, void ratio and the resistance of chloride ion permeation compared to the Type I cement with the lapse of ages. On the other hand, the compressive strength, the void ratio and the chloride diffusion coefficient of the concrete all indicated high levels of the correlation coefficient and the coefficient of determination regardless of the type of cement.

Specific Growth Rates of Microalgae in Different Types of Model Photobioreactors (모형 배양조 형태에 따른 단세포 조류의 비증식속도)

  • KWAK Jung-Ki;KIM Hyun-Ju;LEE Ji-Hyun;SHIN Ga-Hee;CHO Man-Gi;HAN Bong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.477-482
    • /
    • 1998
  • In the aquaculture industry, a photobioreactor (Pbr) with high productivity is a prerequisite for mass production of Chlorella sp., a feeding fry for Rotifer (Brachinous plicatilis). To enhance the productivity of Chlorella sp., model Pbrs such as Cylinder type, Spherical surface type, Half-spherical surface type, Plate type, Raceway pond type and Water-wheel type Pbr with different values of surface area exposed to light/culture volume (S/V) were manufactured, and the maximum specific growth rate (${\mu}_{max}$) and productivity of Chlorella vulgaris 211-11b at $25^{\circ}C$, pH 7.0 and 12,000 lux were compared each other. The ${\mu}_{max}$ and productivity were not proportional to S/V. Among the 6 model Pbrs, Half-spherical surface type Pbr showed the highest ${\mu}_{max}$ and productivity as 2.206 ($day^{-1}$) and 0.247($g^{{\ell}-1}day^{-1}$).

  • PDF

Analysis of highway reflection noise reduction using transparent noise barrier types

  • Lee, Jaiyeop;Kim, Ilho;Chang, Seoil
    • Environmental Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.383-391
    • /
    • 2015
  • Transparent type noise barrier is a desirable facility since it provides a secure view to drivers and passengers. However, reflection from this type of barrier could annoy dwellers on the sides of the road. To reduce reflection noise by transparent type barrier, modification can be made to the shapes on the front side and hence get effects by distortion of sound transmission. To achieve this, we have conducted simulation by which the effects of patterned screens of noise barrier on high-ways were investigated. The reduction effects of reflected sounds were evaluated for swelling, swelling with curved, rectangular and V-shaped screen type barriers, compared to the planar panel. The emitting noise was generated by 6-lane road and the patterned noise barriers had shown the reduction effects, especially in swelling and swelling with curved type for middle height dwellers, and the V-shaped screen type for higher elevation dweller. The swelling-type showed a decrease of 0.7~1.2 dB, performing the best diminution effect among the tested noise barriers.

Characteristics on the Transformer-Type SFCL According to Reclosing Operation the Voltage Increase (전압증가 시 재폐로 동작에 따른 변압기형 초전도 한류기의 특성 분석)

  • Choi, Soo-Geun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.477-480
    • /
    • 2010
  • Fault current in power system is expected to increase by demand of power capacity. Therefore, when the fault occurred, fault current was increased in the power system. Many studies have been progressed to limit the fault current. Superconducting fault current limiter (SFCL) is one of them which has been studied in worldwide. In this paper, we will analyze characteristics of a transformer-type SFCL by reclosing operation when the voltage increases. Twice opening times in the reclosing of circuit breaker were set as the 0.5 and 15 seconds, respectively. Turn's number of primary and secondary coils set 4:2 and we increased voltages from 120V to 280V for each experiment. By the current waveform, maximum fault current in second and third cycles was lowered when the voltage was increased. In the recovery waveform, recovery time was increased as the voltage was increased. The reason was that power burden of the SFCL increased when consumption power was increased, so the time to get back to SFCL took longer. We compared the characteristics of a resistive-type and transformer-type SFCL. As a result, we found that the fault current of a transformer-type was lower than resistive-type and recovery time of the SFCL was shorter. Consequently, transformer-type SFCL was more profitable for limitation of fault current and recovery time under the same condition for reclosing operation.

A Design of Digital Instrumentation Amplifier converting standard sensor output signals into 5V voltage-output (표준 센서 출력신호를 5V 전압-출력을 변환하는 디지털 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.11
    • /
    • pp.41-47
    • /
    • 2011
  • A novel digital instrumentation amplifier(DIA) converting universal signal inputs into 5V voltage-output for industry standard sensor signal processing was designed. The circuit consists of a commercial instrumentation amplifier, seven analog switches, two voltage references of 1.0V and -10.0V, and four resistors. The converting principle is the circuit reconstruction by switches for resistor values and reference voltages according to input signals. The simulation result shows that the DIA has a good output voltage characteristics of 0~5V for the input voltage of 0V~5V, 1V~5V, -10V~+10V, and 4mA~20mA. The nonlinearity error was less than 0.1% for the four type signal inputs.

A Study on the Postpartum Depression Experience : Q-Methodological Approach (산후 우울 경험에 관한 연구 -Q 방법론적 접근-)

  • 장혜숙;김수진;김정선;김흥규;최의순
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.4
    • /
    • pp.917-929
    • /
    • 1996
  • The purpose of this study is to explore types of postpartum depression and to understand the nature and structure of the postpartum depression by using Q-methodological approach. As a way of research, 55 statements concerning postpartum depression were selected through individual interviews with postpartum mothers and literature review. 30 women were chosen as a subject group for the study, with opinions shown in 55 statements divided into 9 scales by forced distribution. PC QUANL Program was used for analysis and Q-factors were analyzed by using principal component analysis. As a result, postpartum depression experience was classified into 5 types. There are "Role-Strain Type", "Unattributional Depression Type", "Psychosomatic Symptoms Type", "Self-Compassion Type", and "Role-Crisis Type". Type I was named "Role-Strain Type", referring to the strain generally experienced by mothers with regard to the new role as a mother and as a social member. Type II was named "Unattributional Depression Type", referring to the symptom experienced by people who were in a state of vanity and a sense of loss. They often break into tears for no specific reasons. In case of Type III, people in a state of "Psychosomatic Symptoms Type" develop physical symptoms after suffering from inherent emotional conflict. Type IV was named "Self-Compassion Type" refers to the symptom shown by those who feel pity for their children and for themselves. And they show inability to cope with the reality properly. Type V was named "Role -Crisis Type", which is experienced by people who have a burden and a severe fear of their own job and their children in their mind, also showing serious conflict with maternal role. Futhermore, it was carried out to examine structure of postpartum depression in terms of degree of depression and adjustment ability. Type I showed mild degree of depression and relatively good adjustment ability. Type II showed broad range of degree in depression and moderate adjustment ability. Type III showed moderate depression and relatively low adjustment ability. Type IV revealed relatively serious degree of depression and the lowest adjustment ability. Type V revealed very serious degree of depression and the lowest adjustment ability. As a result, considering the structure of postpartum depression. Type I is considered to be a normal depression sympton which most mothers generally experience, followed by Type II, Type III, Type IV and Type V, each of which show increasingly worse degree of depression and lower adjustment ability. In conclusion, it seems to be it is necessary to understand distinct symptoms of postpartum depression and to examine the characteristics and structure of those types, so that it could lead to more individual nursing approach.cteristics and structure of those types, so that it could lead to more individual nursing approach.

  • PDF

Collection Efficiency Enhancement of Spray Tower Scrubber by Introducing Electrospray with Two-flow Nozzle (분무탑식 스크러버에서 이류체 정전분무에 의한 집진효율의 향상)

  • Hwang, You-Seong;Kim, Jong-Ho;Kim, Jong-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.339-345
    • /
    • 2010
  • There have been a number of efforts to satisfy national emission regulations and reduce the amount of emitted air pollutants. There are several air pollution control devices, however, only wet scrubber is efficiently used to remove particulate matters and gaseous pollutants, even if it has minimum collection efficiency in the particle size range of $0.1{\sim}1{\mu}m$. This study aimed to improve the collection efficiency of a spray tower type scrubber by introducing an electrospray system with two-flow nozzle. We found that the collection efficiency of a spray tower type scrubber was similar to that of a conventional wet scrubber. However, installation of an electrospray system in the scrubber resulted in drastic further improvement of collection efficiency comparing to that of a conventional scrubber, which is 26%, 35.2%, and 45.1% at the liquid to gas ratio of 0.26 $L/m^3$ and 19.9%, 35.1%, and 42.5% at 0.34 $L/m^3$ for the applied voltage of -30 kV, -35 kV, and -40 kV, respectively. Therefore, we found that the introduction of an electrospray system is very effective to improve the collection efficiency of a spray tower type scrubber.

Gas Detecting Characteristics Using Catalytic Combustion Type Gas Sensor (접촉연소식 가스 센서를 이용한 감도특성)

  • Yoon, Hun-Ju;Ko, Keel-Young;Lee, Jong-Pil;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.773-777
    • /
    • 2002
  • In this study, we analyzed the LPG and LNG sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 0~85 percent at a temperature of $20[{\mu}m]$ and humidity of 45 percent at a temperature of $-10{\sim}40[^{\circ}C]$ the gas detecter sensors are to be subjected to operation for 210 days in an area that has been detemined to be equivalent to a typical residential atmosphere with an air velocity of 50 [cm/sec]. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a separate source of supply direct applied voltage 2.1[V], 2.2[V], 2.3[V]. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the LPG characteristic graph and methane characteristics graph by a relative humidity of 0 ~ 85 [%] at a temperature range of $-10{\sim}40[^{\circ}C]$ show a similar linear pattern on the whore.

  • PDF

A Study on Effects of Fuel Injection System on the Performance in a V8-Type Diesel Engine (V8형 디젤엔진의 성능에 미치는 분사계의 영향에 관한 연구)

  • 박병학
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.248-256
    • /
    • 1998
  • The effects of fuel injection system on the performance in a V8-type diesel engine was stuided in this paper. Fuel injection system is important factor which influence the engine performance and exhaust emission bcasuse the properties in the injected fuel depend on the atomization characteristics. In this study using diesel engine of 17.7:1 compression ration the engine performance and exhaust emission are measured experimentally according to 1000, 1400, 2200rpm in the full-load conditions. The chosen parameters for the major system are such diameter shape of combustion chamber and intake system. The results are as follows: As the nozzle hole diameter and injection angle become smaller and as the injection timing gets advanced the fuel consumption and concentration of smoke are decreasing whereas concentration of $NO_{x}$ is increasing. Andconcentration of $NO_{x}$ is increasing in accordance with the increase of injection pipe diameter and nozzle protrusion. Also it is shown that re-entrant type combustion chamber is more effective than that of toroidal type in the improvement of $NO_{x}$ reduction.

  • PDF