• Title/Summary/Keyword: Type V

검색결과 5,529건 처리시간 0.04초

GLOBAL SOLUTIONS OF SEMIRELATIVISTIC HARTREE TYPE EQUATIONS

  • Cho, Yong-Geun;Ozawa, Tohru
    • 대한수학회지
    • /
    • 제44권5호
    • /
    • pp.1065-1078
    • /
    • 2007
  • We consider initial value problems for the semirelativistic Hartree type equations with cubic convolution nonlinearity $F(u)=(V*{\mid}u{\mid}^2)u$. Here V is a sum of two Coulomb type potentials. Under a specified decay condition and a symmetric condition for the potential V we show the global existence and scattering of solutions.

V련 현수애자장치의 횡진특성과 실선로 적용 (A Swing Characteristics and Application Condition of the V type Suspension String Set)

  • 손홍관;이형권;금의연;민병욱;최진성;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.627-629
    • /
    • 2004
  • V type suspension string sets prevent instabilities from swing motion by the horizontal angle and by wind pressure. These installation conditions are controled mainly 3 items - normal swing angle by horizontal angle of line, unusual swing angle by strong wind, minimum vertical loads. We calculated and analysed that factors for the 765kV transmission line condition. And we were tested swing characteristics of V-string sets in real size test situation. So, we find to installation condition for the V type suspension string sets. This results will be used to design of V type suspension string set and to decision of the installation condition.

  • PDF

차동기어장치와 V-벨트식 변속기구를 결합한 무단변속기의 성능 (Performance of CVTs Composed of a Differential Gear Unit and a V-belt Drive)

  • 최상훈
    • 한국정밀공학회지
    • /
    • 제20권2호
    • /
    • pp.199-208
    • /
    • 2003
  • Continuously variable transmission (CVT) mechanisms considered here combine the functions of a K-H-V type differential gear unit and a V-belt type continuously variable unit (CVU). As combining the functions of a K-H-V type differential gear unit and a V-belt type CVU, 24 different mechanisms are presented. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed. These mechanisms have many advantages which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral.

정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) I. 표준지유도(標準肢誘導) (Studies on electrocardiogram of the normal Korean native cattle I. Standard limb leads)

  • 최인혁;정인성;김남수;서두석
    • 대한수의학회지
    • /
    • 제33권4호
    • /
    • pp.719-734
    • /
    • 1993
  • The electrocardiographic(ECG) parameters on the standard limb leads in the normal Korean native cattle have been measured with a 3 channel Electrocardiograph built in a computed analysis. The study was conducted on the animals 98 heads of mean age of 17.7 months. Conduction parameters, waves, intervals and segments have been recorded. The recordings were analyzed as to shape and amplitude of the P and T waves and the components of the QRS complex. Heart rate was recorded by the Electrocardiogram which were a mean of $80.4{\pm}11.6beats/min$. And the younger had a higher heart rate than the older one. Average conduction times in the RP, the QRS complex and the QTc interval recorded $166.7{\pm}23.1msec.$, $79.7{\pm}8.8msec.$ and $395.5{\pm}30.4msec.$, in the P and T wave duration recorded $70.1{\pm}13.5msec.$ and $97.6{\pm}16.9msec.$, and in the PR and ST segment duration recorded $97.9{\pm}23.5msec.$ and $173.9{\pm}40.3msec.$, respectively. The wave forms in each lead observed various types. The amplitudes of wave type showed the highest frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of the positive type showed the frequency of 65.3%, 82.7% and 52.0% in leads I, II and III that were $103.1{\pm}47.8{\mu}V$, $115.2{\pm}37.3{\mu}V$ and $67.4{\pm}26.9{\mu}V$, and it showed the frequency of 54.1% and 85.7% in the leads aVL and aVF that were $63.7{\pm}23.0{\mu}V$, $88.0{\pm}83.6{\mu}V$, respectively. Average amplitude of the negative type showed the frequency of 78.6% in lead aVR which was $99.3{\pm}38.0{\mu}V$. 2. Average amplitude of the QRS complex were from $362.8{\pm}177.7{\mu}V$ to $532.8{\pm}253.9{\mu}V$(mean of $449.1{\pm}57.2{\mu}V$) that in all leads except lead I were manifested the Low-Voltage QRS complex(below 0.5mV). Average amplitudes of each wave type in the QRS complex aere $-50.2.4{\pm}258.2{\mu}V$ and $-428.6{\pm}195.1{\mu}V$ in the QS groups type that showed a frequency of 66.3%, 70.4% in the leads I and aVL, were $451.1{\pm}20.4.0{\mu}V$, $387.6{\pm}175.8{\mu}V$ and $299.3{\pm}146.5{\mu}V$ in the R groups type that showed a frequency of 48.0%, 53.1% and 34.7% in the leads III, aVR and aVF, and were $-307.5{\pm}180.3{\mu}V$, $201.4{\pm}77.2{\mu}V$ in the QR wave type which showed a frequency of 39.8% in lead II, respectively. 3. In T wave, amplitude of the positive type showed the frequency of 50.0%, 82.7%, 51.0% and 57.1% in leads II, III aVR and aVF which were $214.9{\pm}115.6{\mu}V$, $188.5{\pm}119.3{\mu}V$, $191.0{\pm}93.7{\mu}V$ and $165.7{\pm}91.9{\mu}V$, and the negative type showed a frequecny of 66.3% and 72.5% in leads I and aVL. that were $221.3{\pm}112.5{\mu}V$, $-173.6{\pm}86.7{\mu}V$, respectively. 4. Amplitude of ST segment in leads I, II and III were a mean of $-12.2{\pm}37.2{\mu}V$, $17.5{\pm}42.6{\mu}V$ and $28.3{\pm}40.4{\mu}V$, in leads aVR, aVL and aVF were $-3.9{\pm}32.5{\mu}V$, $-15.9{\pm}35.6{\mu}V$ and $26.2{\pm}37.5{\mu}V$, respectively.

  • PDF

Two Types of Voltage-activated Calcium Currents in Goldfish Horizontal Cells

  • Paik, Sun-Sook;Bai, Sun-Ho;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제9권5호
    • /
    • pp.269-273
    • /
    • 2005
  • In horizontal cells (HCs) that were freshly dissociated from goldfish retina, two types of voltagedependent calcium currents ($I_{Ca}$) were recorded using a patch-clamping configuration: a transient type current and a sustained type current. The cell was held at -40 mV, and the prepulse step of -90 mV was applied before command pulse between -65 and +55 mV. The transient $Ca^{2+}$ current was activated by depolarization to around -50 mV from a prepulse voltage of -90 mV lasting at least 400 ms and reached a maximal value near -25 mV. On the other hand, the sustained $Ca^{2+}$ current was induced by pre-inactivation for less than 10 ms duration. Its activation started near -10 mV and peaked at +20 mV. $Co^{2+}$ (2 mM) suppressed both of these two components, but nifedipine ($20{\mu}M$), L-type $Ca^{2+}$ channel antagonist, blocked only the sustained current. Based on the activation voltage and the pharmacolog$I_{Ca}$l specificity, the sustained current appears to be similar to L-type $I_{Ca}$ and the transient type to T-type $I_{Ca}$. This study is the first to confirm that transient type $I_{Ca}$ together with the sustained one is present in HCs dissociated from goldfish retina.

미생물 농도에 따르는 Air-Cathode MFC의 전력발생과 유기물질제거 특성 (Characteristics of Power Generation and Organic Matter Removal in Air-Cathode MFC with respect to Microbial Concentration)

  • 김도영;임봉수;최찬수;김대현
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.917-922
    • /
    • 2012
  • In order to improve applicability of a microbial fuel cell the laboratory-scaled study has been performed by adopting an air-cathode MFC system with high concentrated anaerobic slugies in this study. The concentrations of microbes are grouped into three types, Type A (TS 1.7%), Type B (TS 1.1%) and Type C (TS 0.51%). The open circuit voltage $(V_{oc})$ characteristics showed that the medium microbes concentration of 1.10% (Type B) kept a constant voltage of 1.0 V for 150 hours, which showed the longest time among three types (Type A and Type C). The discharge charge curves for a closed circuit with $500 \Omega$ also showed that Type B generated a stable discharge voltage of 0.8 V for a longer time as in the open circuit voltage case. This could be explained by the relatively large amount of the attached microbes. Under the $V_{oc}$condition the COD removal efficiency of Type B was found to be low for a long time, but those of Type A and C were found to be high for a short period of time. Therefore, the suspended microbes could decrease the coulombic efficiency. It was concluded that the high $V_{oc}$ was caused by low COD and the $V_{oc}$ became low after the COD removal. The COD reduction resulted in an unstable and low working voltage. From the polarization characteristics Type A was found to show the highest power density of $193\;mW/m^2$ with a fill factor of 0.127 due to the relatively high remaining COD even after the MFC reaction.

직렬-복합소호형 모델 가스차단기의 차단성능평가 (Estimation of Interruption Capability of a Serial-Hybrid Type Model Gas Circuit Breaker)

  • 송기동;정진교;박경엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.538-544
    • /
    • 2004
  • This paper presents the interruption capability of serial-hybrid type GCB (gas circuit breaker) compared with that of puffer type. First a puffer type model interrupter which has the stroke length of 80 mm has been designed and manufactured. And also, a serial-hybrid type interrupter which has the same design parameters as the puffer type interrupter except the serially arranged thermal-expansion chamber and puffer cylinder has been fabricated. Using a simplified synthetic test facility, the critical interruption capabilities of the two GCBs have been estimated. The critical di/dt, the critical dV/dt of ITRV (initial transient recovery voltage) and the minimum arcing time of the puffer type model GCB were 10.7 A/${\mu}\textrm{s}$, 5.5 kV/${\mu}\textrm{s}$, and 15.0 ms respectively. In the case of serial-hybrid type model GCB, each of the values was 16.6A/${\mu}\textrm{s}$, 11.5 kV/${\mu}\textrm{s}$ and 13.0 ms. As a conclusion of this work, it has been quantitatively confirmed that the hybrid type interrupter can obtain the sufficient interruption capability at the operating force which is so low that puffer type interrupter has not the interruption capability.

DTNB oxidation effects on T-type $Ca^{2+}$ channel isoforms

  • Lee, Sang-Soo;Kang, Ho-Won;Park, Jin-Yong;Lee, Jung-Ha
    • Animal cells and systems
    • /
    • 제15권2호
    • /
    • pp.131-138
    • /
    • 2011
  • Redox regulation is one of the ubiquitous mechanisms to modulate ion channels. We here investigated how 5,5'-dithio-bis (2-nitrobenzoic acid), a cysteine specific oxidizing reagent, modulates $Ca_v3.1$ and $Ca_v3.2$ T-type $Ca^{2+}$ channels expressed in Xenopus oocytes. Application of the reagent inhibited $Ca_v3.1$ and $Ca_v3.2$ currents in a dose-dependent manner. The oxidizing reagent (1 mM) reduced the peak amplitude of $Ca_v3.1$ and $Ca_v3.2$ currents by ~50% over 2-3 minutes and the decreased currents were fully recovered upon washout of it. The reagent slowed the activation and inactivation kinetics of $Ca_v3.1$, $Ca_v3.2$, and $Ca_v3.3$ channel currents. Notably, the reagent positively shifted both activation and steady-state inactivation curves of $Ca_v3.1$, while it did not those of $Ca_v3.2$. Utilizing chimeric channels from $Ca_v3.1$ and $Ca_v3.2$, we localized the domains III and IV of $Ca_v3.1$ responsible for the positive shifts of channel activation and steady-state inactivation. These findings provide hints relevant to the electrophysiological and molecular mechanisms accounting for the oxidative regulation of T-type channels.