• Title/Summary/Keyword: Type IV stone

Search Result 35, Processing Time 0.025 seconds

Comparative Study of the Surface Roughness of Working Models Fabricated by Dental CAD/CAM Scannable Stone and Type IV Gypsum Products (치과용 캐드캠 스캔전용 석고와 Type IV 석고로 제작된 작업모형의 표면조도 비교 연구)

  • Kim, Sa-Hak;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.455-460
    • /
    • 2014
  • This study compared the surface roughness and surface characteristics between a type IV stone and scannable stone. Materials used were a type IV stone, two different kind of scannable stone. Ten specimens per experimental group were prepared according to manufacturer's direction. Surface roughness of specimen was measured using profilometer. The measurement was based on the standard of Japanese Industrial Standards 1994. The mean and standard deviations of each reference point were analyzed using one-way ANOVA and Scheff$\acute{e}$ post hoc test. The program used to handle statistical analysis was SPSS 20.0 and the significance level was set at 0.05. The difference of surface roughness was statistically significant in order of Scannable Stone $10.07{\pm}0.02{\mu}m$, Scannable Stone $20.08{\pm}0.03{\mu}m$, Type IV $0.10{\pm}0.04{\mu}m$. These results will have to be confirmed in further clinical application researches.

A comparison of surface hardness and microstructural characteristics between a type IV stone with and without die hardening treatment, and a polyurethane resin die material (IV형 경석고와 경화처리된 IV형 경석고 그리고 폴리우레탄 수지 치형재의 표면경도와 미세구조 특성의 비교)

  • Lee, Wan-Sun;Kim, Ji-Hwan;Kim, Tae-Suk;Kim, Nam-Sic;Yu, Chin-Ho
    • Journal of Technologic Dentistry
    • /
    • v.34 no.3
    • /
    • pp.227-235
    • /
    • 2012
  • Purpose: This study compared the surface hardness (Vickers) and microstructural characteristics between a type IV stone with and without die hardening treatment, a polyurethane die material. Methods: Materials used were a type IV stone(MG Crystal Rock), two die hardeners (Hardening bath, Epox-it), and a polyurethane resin material(Polyluck). Six specimens per group were prepared according to manufacturer's directions. The prepared specimens were tested by means of hardness test, one-way ANOVA analysis, scanning electron microscopic(SEM) observations and energy dispersive spectroscopic(EDS) analysis. Results: In the hardness test and its statistical analysis, there was no significant difference in the surface hardness between a type IV stone and type IV stone with die hardener coating, type IV stone mixed with an epoxy like material instead of water. In contrast, polyurethane resin material exhibited significantly greater surface hardness than other specimen groups (p<0.05). Conclusion: By considering the results of the hardness test, SEM observations and EDS analysis, although the die hardeners on type IV stone did not show remarkable improvement in surface hardness, the die hardener coating on the surface of type IV stone material did show decrease of microporous and improvement of surface defects.

A STUDY ON THE ABRASION RESISTANCE AND SURFACE ROUGHNESS OF THE DENTAL STONES (수종 치과용 석고의 마모저항도 및 표면조도에 관한 비교 연구)

  • Shim, Hye-Won;Yi, Yang-Jin;Cho, Lee-Ra;Chung, Kyung-Ho;Kim, Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.184-192
    • /
    • 2002
  • The purpose of this study was to investigate the abrasion resistance and surface roughness of conventional dental stones and improved dental stones and newly developed dental stones. Materials included in this study were several dental stones and newly developed dental stone; 2 type III. 6 type IV (including newly developed dental stone). 1 type V Ten specimens for each material, total ninety specimens were made. Each specimen was subjected to 50 complete cycle abrasion under constant load 0.42N at speed or 6mm per sec. The depth after abrasion test was measured for each specimen. Surface roughness before and after abrasion test was compared. The results were as follows ; 1. The resin containing die materials such as Tuff Rock and Resin Rock had superior abrasion resistance. 2. Type IV, V dental stone exhibited greater abrasion resistance than Type III dental stone. 3. The results or the surface roughness showed similar pattern with the abrasion resistance.

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

A STUDY ON THE CONTACT ANGLE AND WETTABILITY OF THE DENTAL STONES (수종 치과용 석고의 접촉각 및 젖음성에 관한 비교 연구)

  • Cho Lee-Ra;Chung Kyung-Ho;Kim Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.61-70
    • /
    • 2003
  • The purpose of this study was to investigate the contact angles and wettability of conventional dental stones and improved dental stones and newly developed dental stones on several impression materials. Materials included in this study were several dental stones and newly developed dental stone ; 2 type III stones (Snow Rock, New Diastone), 6 type IV stones(Crystal Rock, Vel Mix, Fuji Rock, Tuff Rock, Resin Rock and newly developed dental stone) and 1 type V stone (Die Keen). Contact angles on the impression materials were measured with contact angle measuring device. Ten specimens for each material, total 180 specimens were made on void entrapment model. The two impression materials (Handae, GC) were used to produce 9 groups of die stone casts form void entrapment model. Voids in the stone casts were counted under a stereoscopic microscope. The grad for the reproduction ability of each materials on the void entrapment model was calculated from the casts by one examiner. From the experiment, the following results were obtained : 1. The newly developed stones showed smallest contact angle. Type III dental stone had larger contact angles than type IV and V stones. Contact angle was much affected by the impression materials. 2. Resin containing die materials such as Tuff Rock and Resin Rock had smallest void number than any other groups. 3. In comparing reproduction parameters, Tuff Rock and Resin Rock presented superior results, while Vel Mix showed lowest reproduction ability.

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Study on the Improvement of Milling Recovery and Performance (IV) -Rice Whitening Performance of the Combined Abrasive- and Friction-type Whiteners- (도정수율(搗精收率)과 성능향상(性能向上)을 위(爲)한 연구(硏究)(IV) -연삭(硏削)·마찰(磨擦)의 조합식(組合式) 정백작용(精白作用)이 정백성능(精白性能)에 미치는 영향(影響)-)

  • Kim, Sam Do;Chung, Chang Joo;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.72-85
    • /
    • 1983
  • Rice whitening is performed by basically two different whitening actions known as abrasive and frictional. The former adopted in the emery stone abrasive type whiteners and the latter in the jet-air friction type. Comparative milling yields and whitening efficiencies between the whitening system consisting of jet-air friction type whiteners only and the system consisting of both abrasive- and jet-air friction-types have not yet been rigorously defined. This study was to examine the effect of combined operations of abrasive- and jet-air friction-type rice whiteners on milling yields and whitening efficiencies. The small capacity commercial units of the abrasive- and friction-type whiteners were used for the experiments. The combinations of whitening treatments were: 1) Once in the abrasive type and then two to three times in the friction type, 2) twice in the abrasive and then two to three times in the friction type and 3) three to five times in friction type. In these tests, counter pressures for the friction type whiteners were established differently as required to get about the same degree of whitening at the end of predetermined numbers of the repeated operations. The speed of emery stone and the slot angle of the screen were also the factors varied in the abrasive type whitener. Sheukwang rice variety having 13.05% M.C. was used in the tests. The dependent variables were the milled- and head-rice recoveries and electricity consumption. The results of the study are summarized as follows: 1. It was found that in the whitening systems consisting of abrasive- and friction-type whiteners slot angle of the screen, the rotational speed of emery stone roller had significant effect on the milling yields and whitening efficiency. In general, the increase of the emery stone roller speed from 690 to 950 rpm presented a positive effect on milling yield, and one-pass abrasive milling combinations had higher milling yields than two-pass abrasive milling combinations. 2. It was apparent that if the slot angle of the screen and the speed of emery stone roller are modified and set at an optimum level, the combination whitening system consisting of abrasive- and friction-type whiteners is better than the pure frictional whitening system consisting of jet-air friction type in terms of milling yields and efficiencies. 3. In the rice whitening system consisting of abrasive- and jet-air friction-type whiteners, the best whitening performance was obtained when the slot angle of the screen and the rotational speed of emery stone roller were $45^{\circ}$ and 950rpm, respectively, for the one-pass abrasive milling combinations. However, for the two-pass abrasive mi11ing combinations, the best performance was obtained with $75^{\circ}$ of slot angle and 950 rpm of the emery stone roller speed. 4. As compared with pure frictional whitening systems, the combination systems produced more milled rice by 0.8-1.0% point and more head rice by 0.5-1.5% point, and consumed less electricity by 0.15-0.20 KwH per 100kg of milled rice when the abrasive whiteners were operated in the modified conditions as described in item 3 above. Further study is recommended to find out optimum operational and design conditions of abrasive type whiterners.

  • PDF

Transformation characteristics of stylobate and staircase of post-lintel Construction of Backje and Silla Style (백제계 및 신라계 가구식 기단과 계단의 시기별 변화특성)

  • Nam, Chang-Keun;Kim, Tai-Young
    • Journal of architectural history
    • /
    • v.21 no.1
    • /
    • pp.99-118
    • /
    • 2012
  • This study aims to classify the architectural formation of the Stylobate of and Staircase types of Post-Lintel Construction in Backje style and Silla style and also to figure out their specific elements by periods and transformation characteristics. The scope of this study was restricted to architectural remains between the Three Kingdom period and the Goryeo period. To progress the investigation, the study classified remains in a similar type by period and type, and then and analyzed its character based on formation method and specific factors of subsidiary materials. As a result, its type can be classified as Backje type(I), Silla type(II) and Mixed type(III). Regionally, it is found that Woongjin, Sabi and surroundings in the capital of Backje, Gyeongju and main towns in the capital of Silla, and Gaeseong and main towns in the capital of Goryeo. In particular, type III has the characteristics of type I and II simultaneously, which has one or two layers Jangdaeseok stone between the foundation stone of stylobate and plate stone, and tends to be decorative when Taengjuseok stone is installed. For types of staircase, it could be classified as 6~7C Backje type(I), 7~9C Silla type(II) and 9C Mixed type(III) according to the formation method of Somaetdol (banister of stone stair). And from the 9th century on, decorated Somaetdol stone type(IV) of 1/4 circle shape began to appear. The common feature of stylobate of post-lintel and staircase is that it became simplified, abbreviated and decorative. It seems to be intended to secure simplicity of construction or structural stability.

EFFECT ON IMMERSI0N DISINFECTION OF HYDROPHIILIC RUBBER IMPRESSI0N MATERIAL ON DIMENSIONAL STABILITY AND SURFACE HARDNESS OF IMPROVED STONE CAST (친수성 고무인상재의 침적 소독이 경석모형의 크기의 안정성과 표면경도에 미치는 영향)

  • Nam, Mee-Hyun;Kang, Woo-Jin;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.569-583
    • /
    • 1995
  • Disinfection of dental impressions are necessary due to contamination with patient’s saliva and blood, which is a potential for cross-infection. The purpose of this study was to evaluate the effects of disinfection of four hydrophilic rubber impression materials with three disinfecting solutions, on the dimensional stability and surface hardness of improved stone casts. Three hydrophilic vinyl polysiloxane impression materials(Express, Reprosil, Exafine) and one polyether impression material(Impregum-F) were mixed according to the manufacturer’s directions and impressions were made on a ADA specification No. 19 stainless-steeldie. On removal of the impressions, each impression was immersed in one of the disinfectants(Banicide, Potadine, Clorox) for 10 minutes. After disinfection, type IV improved stone. casts were poured. On this cast, the linear dimension and surface hardness were measuredusing a Measurescope(Nikon, Japan) and a Barcol hardness tester(Barber, Colman Co U. S. A). The results were as follows : 1. The improved stone casts from disinfected Reprosil and Impregum-F impression material did not show dimensional changes(P>0.01). Those from disinfected Express and Exafine impression material showed dimensional changes(P<0.01). The amount of shrinkage was not clinically significant. 2. The improved stone casts from disinfected Express impression material did not exhibit changes in surface hardness(P>0.01), but those from disinfected Reprosil, Exafine, Imp regnum-F impression material showed changes in surface hardness(P<0.01). 3. The dimensinal stability and surface hardness of the improved stone casts were satisfactory using Banicide on Express, all disinfectants used in this study on Reprosil, Potadin and Clorox on Exafine, Banicide and Clorox on Impregum-F. According to these results, immersion disinfection of hydrophilic rubber impression mate rials did not adversely affect the resultant casts. Nevertheless compatibility tests of impression materials and disinfectants should be done when disinfecting impressions.

  • PDF

Comparison of the accuracy of digital models made from white light scanner by scanning method (스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Jae-Hong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.6
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.