• 제목/요약/키워드: Two-load method

검색결과 2,066건 처리시간 0.03초

Lateral stiffness of corner-supported steel modular frame with splice connection

  • Yi-Fan Lyu;Guo-Qiang Li;Ke Cao;Si-Yuan Zhai;De-Yang Kong;Xuan-Yi Xue;Heng Li
    • Steel and Composite Structures
    • /
    • 제48권3호
    • /
    • pp.321-333
    • /
    • 2023
  • This paper proposes a comprehensive investigation on lateral stiffness of corner-supported steel modular frame using splice connection. A full-scale modular frame with two stacked steel modules under lateral load is tested. Ductile pattern in the transfer of lateral load is found in the final failure mode. Two types of lateral stiffness, including tangent stiffness and secant stiffness, are defined from the load-displacement due to the observed nonlinearity. The difference between these two types of stiffness is found around 20%. The comparisons between the experimental lateral stiffness and the predictions of classical methods are also conducted. The D-value method using hypothesis of independent case is a conservative option for predicting lateral stiffness, which is more recommended than method of contraflexural bending moment. Analyses on two classical short-rod models, including fix-rod model and pin-rod model, are further conducted. Results indicate that fix-rod model is more recommended than pin-rod model to simplify splice connection for simulation on lateral stiffness of modular frame in elastic design stage.

Mechanics based analytical approaches to predict nonlinear behaviour of LSCC beams

  • Thirumalaiselvi, A.;Anandavalli, N.;Rajasankar, J.
    • Structural Engineering and Mechanics
    • /
    • 제64권3호
    • /
    • pp.311-321
    • /
    • 2017
  • This paper presents the details of analytical studies carried out towards the prediction of flexural capacity and load-deflection behaviour of Laced Steel-Concrete Composite (LSCC) beams. Analytical expressions for flexural capacity of the beams are derived in accordance with the basic principles of conventional Reinforced Concrete (RC) beams, but incorporated with relevant modifications to account for the composite nature of the cross-section. The ultimate flexural capacity of the two LSCC beams predicted using the derived expressions is found to be approximately 20% lower than those obtained due to measurement from experiments. Further to these, two simple methods are also proposed on the basis of unit load method and equivalent steel beam method to determine the non-linear load-deflection response of the LSCC beams for monotonic loading. Upon validation of the proposed methods by comparing the predicted responses with those of experiments and finite element analysis, it is found that the methods are useful to find nonlinear response of such composite beams.

Evaluation of multi-lane transverse reduction factor under random vehicle load

  • Yang, Xiaoyan;Gong, Jinxin;Xu, Bohan;Zhu, Jichao
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.725-736
    • /
    • 2017
  • This paper presents the two-, three-, and four-lane transverse reduction factor based on FEA method, probability theory, and the recently actual traffic flow data. A total of 72 composite girder bridges with various spans, number of lanes, loading mode, and bridge type are analyzed with time-varying static load FEA method by ANSYS, and the probability models of vehicle load effects at arbitrary-time point are developed. Based on these probability models, in accordance to the principle of the same exceeding probability, the multi-lane transverse reduction factor of these composite girder bridges and the relationship between the multi-lane transverse reduction factor and the span of bridge are determined. Finally, the multi-lane transverse reduction factor obtained is compared with those from AASHTO LRFD, BS5400, JTG D60 or Eurocode. The results show that the vehicle load effect at arbitrary-time point follows lognormal distribution. The two-, three-, and four-lane transverse reduction factors calculated by using FEA method and probability respectively range between 0.781 and 1.027, 0.616 and 0.795, 0.468 and 0.645. Furthermore, a correlation between the FEA and AASHTO LRFD, BS5400, JTG D60 or Eurocode transverse reduction factors is made for composite girder bridges. For the two-, three-, and four-lane bridge cases, the Eurocode code underestimated the FEA transverse reduction factors by 27%, 25% and 13%, respectively. This underestimation is more pronounced in short-span bridges. The AASHTO LRFD, BS5400 and JTG D60 codes overestimated the FEA transverse reduction factors. The FEA results highlight the importance of considering span length in determining the multi-lane transverse reduction factors when designing two-lane or more composite girder bridges. This paper will assist bridge engineers in quantifying the adjustment factors used in analyzing and designing multi-lane composite girder bridges.

Flexural behavior of RC beams retrofitted by ultra-high performance fiber-reinforced concrete

  • Meraji, Leila;Afshin, Hasan;Abedi, Karim
    • Computers and Concrete
    • /
    • 제24권2호
    • /
    • pp.159-172
    • /
    • 2019
  • This paper presents an investigation into the flexural behavior of reinforced concrete (RC) beams retrofitted by ultra-high performance fiber-reinforced concrete (UHPFRC) layers. The experimental study has been conducted in two parts. In the first part, four methods of retrofitting with UHPFRC layers in both the up and down sides of the beams have been proposed and their efficiency in the bonding of the normal concrete and ultra-high performance fiber-reinforced concrete has been discussed. The results showed that using the grooving method and the pre-casted UHPFRC layers in comparison with the sandblasting method and the cast-in-place UHPFRC layers leads to increase the load carrying capacity and the energy absorption capacity and causes high bond strength between two concretes. In the second part of the experimental study, the tests have been conducted on the beams with single UHPFRC layer in the down side and in the up side, using the effective retrofitting method chosen from the first part. The results are compared with those of non-retrofitted beam and the results of the first part of experimental study. The results showed that the retrofitted beam with two UHPFRC layers in the up and down sides has the highest energy absorption and load carrying capacity. A finite element analysis was applied to prediction the flexural behavior of the composite beams. A good agreement was achieved between the finite element and experimental results. Finally, a parametric study was carried out on full-scale retrofitted beams. The results indicated that in all retrofitted beams with UHPFRC in single and two sides, increasing of the UHPFRC layer thickness causes the load carrying capacity to be increased. Also, increases of the normal concrete compressive strength improved the cracking load of the beams.

Method for Adjusting Single Matching Network for High-Power Transfer Efficiency of Wireless Power Transfer System

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyungsoo
    • ETRI Journal
    • /
    • 제38권5호
    • /
    • pp.962-971
    • /
    • 2016
  • A wireless power transfer (WPT) system is generally designed with the optimum source and load impedance in order to achieve the maximum power transfer efficiency (PTE) at a specific coupling coefficient. Empirically or intuitively, however, it is well known that a high PTE can be attained by adjusting either the source or load impedance. In this paper, we estimate the maximum achievable PTE of WPT systems with the given load impedance, and propose the condition of source impedance for the maximum PTE. This condition can be reciprocally applied to the load impedance of a WPT system with the given source impedance. First, we review the transducer power gain of a two-port network as the PTE of the WPT system. Next, we derive two candidate conditions, the critical coupling and the optimum conditions, from the transducer power gain. Finally, we compare the two conditions carefully, and the results therefore indicate that the optimum condition is more suitable for a highly efficient WPT system with a given load impedance.

반구형 공기동압베어링의 정적 특성 및 설계 (Static Characteristics and Design of Hemispherical Aerodynamic Bearing)

  • 김승곤;김준영;최환영
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제26회 추계학술대회
    • /
    • pp.217-224
    • /
    • 1997
  • Static characteristics of hemispherical aerodynamic bearing is studied theoretically. In this paper nonlinear equation of second order considering compressibility and slip effect of air is calculated by Newton-Raphson method. Results indicate that axial load capacity has maximum value when the inclination angle of groove is about 30$\circ$, the ratio of groove clearance to ridge clearance is two. We also present the design method of hemispherical Aerodynamic bearing based on it's load capacity taking into account manufacturing and assembling viewpoint.

  • PDF

A Study on New PV Tracking System Including Load Dispersion

  • Lee, Sang-Hun;Song, Hyun-Jig;Park, Chan-Gyu;Song, Sung-Geon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.472-480
    • /
    • 2014
  • The In solar power system, the height and azimuth of the sun are important parameters which control generated power magnitude. The tracking method that controls the daily generation magnitude according to latitude and longitude using the two axles is often used in the existing sunlight tracking system today. In this two-axle PV track control system, the self-load is concentrated on one FRAME. It is influenced of the regular load, snow load and the wind load, etc. It is difficult to set up the system in the conventional building. This research is a development about the small-scale economy track device of independent load-dispersing solar generation system. The position tracking algorithm is through new coordinates transformation calculating the height and azimuth of the sun.

연료전지의 진단 및 부하 평준화를 위한 다중 컨버터 시스템의 설계 (Design of the Multi-converter System for Fuel Cell Diagnosis and Load Leveling)

  • 응웬탄두안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.11-12
    • /
    • 2013
  • In this research, a novel multi-converter system for the fuel cell diagnostics and the load leveling function under varying load condition is proposed. The proposed system is composed of two converters and operates in two different modes. In the normal mode operation the additional bidirectional converter is used for the load leveling and in the diagnostic mode it is used for implementing integral diagnostics by way of electrochemical impedance spectroscopy (EIS). The proposed method can perform the EIS for fuel cell under varying load conditions with no influence to the load. The validity and feasibility of the proposed system is verified by the experiments and the design procedure of the proposed system is detailed.

  • PDF

Dynamic Clustering for Load-Balancing Routing In Wireless Mesh Network

  • Thai, Pham Ngoc;Hwang, Min-Tae;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제10권12호
    • /
    • pp.1645-1654
    • /
    • 2007
  • In this paper, we study the problem of load balancing routing in clustered-based wireless mesh network in order to enhance the overall network throughput. We first address the problems of cluster allocation in wireless mesh network to achieve load-balancing state. Due to the complexity of the problem, we proposed a simplified algorithm using gradient load-balancing model. This method searches for a localized optimal solution of cluster allocation instead of solving the optimal solution for overall network. To support for load-balancing algorithm and reduce complexity of topology control, we also introduce limited broadcasting between two clusters. This mechanism maintain shortest path between two nodes in adjacent clusters while minimizing the topology broadcasting complexity. The simulation experiments demonstrate that our proposed model achieve performance improvement in terms of network throughput in comparison with other clustering methods.

  • PDF

Application of unified equivalent frame method to two-way slab structures with beams

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Cho, Hae-Chang;Lee, Jae-Yeon;Kim, Kang Su
    • Computers and Concrete
    • /
    • 제22권4호
    • /
    • pp.365-372
    • /
    • 2018
  • The current design codes present an equivalent frame method (EFM) for the analysis and design of two-way slab structures. However, since the EFM was developed to be suitable for two-way slab structures subjected to gravity loads only, it brings many problems in its application to the analysis of two-way slabs to which gravity and lateral loads are applied simultaneously. Therefore, authors proposed the unified equivalent frame method (UEFM) that can analyze the structural behavior of flat-plate slab systems subjected to gravity and lateral loads in their previous studies. In this study, the UEFM was modified to be applicable to the two-way slab system with beams. In addition, the accuracy of the proposed UEFM was then examined by comparing it to the lateral behaviors of the two-way slab specimens.