• Title/Summary/Keyword: Two-Layer Model

Search Result 1,154, Processing Time 0.029 seconds

Study on Improving Egg Production System and Economic Analysis of Layer Operation in Korea (채란양계농가의 경영분석과 생산성 제고 방안)

  • 오봉국;정근기;여정수;김재홍;민병열;한성욱
    • Korean Journal of Poultry Science
    • /
    • v.9 no.2
    • /
    • pp.19-62
    • /
    • 1982
  • 1. The primary purpose of this study was to analyse the current status of layer operations in Korea related to management practices and input and output relationship in egg production by surveying 150 egg producers throughout the country. Based on this primary information, this study attempted to illustrate a model layer farming budget. 2. The average size of the layer operations included in this survey was 7,969 hens per farm during the period from September 1, 1980 to August 31, 1981. However, about 80% of the producers started the layer farming with smaller scales than 3,000 layers and less funds than 10 million won during the later half of 1960s and the early half of 1970s. About 72% of the farmers were graduates from high school or college. These egg producers listed that lack of funds and poor production and management skills are the most important problems in the operation. 3. The farmers used to purchase baby chicks from the well-known hatcheries and commercial mixed feeds on one or two months' credit. While the eggs were sold to wholesalers and/or assemblers. Few of the producers market their products directly or cooperatively through the industry organization.

  • PDF

Unsteady Transitional Boundary Layer due to Rotor Stator Interaction at Design and Off Design Operations (설계점 및 탈설계점에서의 rotor-stator 상호작용에 의한 비정상 천이 경계층의 수치해석적 연구)

  • Kang Dong Jin;Jun Hyun Joo
    • Journal of computational fluids engineering
    • /
    • v.4 no.2
    • /
    • pp.17-30
    • /
    • 1999
  • The unsteady transitional boundary layer due to rotor-stator interaction was studied at two operation points, the design and one off design points. The off design point leads to lower blade loading and lower Reynolds number. A Navier-Stokes code developed in the previous study was parallelized to expedite computations. A low Reynolds number turbulence model was used to close the momentum equations. All computations show good agreement with experimental data. The wake induced transitional strip on the suction side of the stator is clearly captured at design point operation. There is no noticeable change in shape and phase angle of the wake induced strip even in the laminar sublayer. The wake induced transitional strip at off design point shows more complex structure. The wake induced transitional strip is observed only in the turbulent layer, and becomes obscure in the laminar sublayer and buffer layer. This behavior is probably consequent upon that the transition is governed by both wake induced strip and natural transition mechanism by Tollmien-Schlichting wave.

  • PDF

Parametric study on the lateral strength of URM wall, retrofitted using ECC mortar

  • Niasar, Alireza Namayandeh;Alaee, Farshid Jandaghi;Zamani, Sohail Majid
    • Earthquakes and Structures
    • /
    • v.18 no.4
    • /
    • pp.451-466
    • /
    • 2020
  • In this paper, the effect of Engineered Cementitious Composites (ECC) on the lateral strength of a bearing unreinforced Masonry (URM) wall, was experimentally and numerically investigated. Two half scale solid walls were constructed and were tested under quasi-static lateral loading. The first specimen was an un-retrofitted masonry wall (reference wall) while the second one was retrofitted by ECC mortar connected to the wall foundation via steel rebar dowels. The effect of pre-compression level, ECC layer thickness and one or double-side retrofitting on the URM wall lateral strength was numerically investigated. The validation of the numerical model was carried out from the experimental results. The results indicated that the application of ECC layer increases the wall lateral strength and the level of increment depends on the above mentioned parameters. Increasing pre-compression levels and the lack of connection between the ECC layer and the wall foundation reduces the influence of the ECC mortar on the wall lateral strength. In addition, the wall failure mode changes from flexure to the toe-crashing behavior. Furthermore, in the case of ECC layer connected to the wall foundation, the ECC layer thickness and double-side retrofitting showed a significant effect on the wall lateral strength. Finally, a simple method for estimating the lateral strength of retrofitted masonry walls is presented. The results of this method is in good agreement with the numerical results.

The Image Changes in the Control Panelipse Radiography by the Control of the Profile Index (Profile Index에 따른 Panelipse Ⅱ 방사선 상층의 변화)

  • Cho Chul-Ho;Sung Jae-Hyun
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 1990
  • This research was made to investigate the change of the image layer and of the vertical and horizontal magnification on the Panelipse radiographic image by the control of profile index. Using the Panelipse, a series of 60 exposures were taken with the steel balls placed in the holes of the plastic model plate, and then evaluated by 4 observers. Two points were assigned for a reading of sharp, one for middling sharp, and zero for unsharp. Each ball image then could be given a total reader score of 0 to 8. The author analyzed the image layer as defined by a sharpness score of 6 or more. The results obtained were as follows: As the profile index was increased, the shape of the image layer was not changed, and the width of the image layer was increased, and the position of the layer shifted away from the rotation center. As the profile index was increased, the ranges of vertical and horizontal magnification was increased, especially the ranges of horizontal magnification was greater than that of vertical magnification.

  • PDF

Effects of Synthetic Turbulent Boundary Layer on Fluctuating Pressure on the Wall (합성난류경계층이 벽면에서의 변동압력에 미치는 영향)

  • Yi, Y.W.;Lee, D.S.;Shin, K.K.;Hong, C.S.;Lim, H.C.
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.92-98
    • /
    • 2021
  • Large Eddy Simulation (LES) has been popularly applied and used in the last several decades to simulate turbulent boundary layer in the numerical domain. A fully developed turbulent boundary layer has also been applied to predict the complicated wake flow behind bluff bodies. In this study we aimed to generate an artificial turbulent boundary layer, which is based on an exponential correlation function, and generates a series of realistic three-dimensional velocity data in two-dimensional inlet section which are correlated both in space and in time. The results suggest its excellent capability for high Reynolds number flows. To make an effective generation, a hexahedral mesh has been used and Cholesky decomposition was applied to possess suitable turbulent statistics such as the randomness and correlation of turbulent flow. As a result, the flow characteristics in the domain and fluctuating pressure near the wall are very close to those of fully developed turbulent boundary layers.

Design of Optimized Radial Basis Function Neural Networks Classifier Using EMC Sensor for Partial Discharge Pattern Recognition (부분방전 패턴인식을 위해 EMC센서를 이용한 최적화된 RBFNNs 분류기 설계)

  • Jeong, Byeong-Jin;Lee, Seung-Cheol;Oh, Sung-Kwun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1392-1401
    • /
    • 2017
  • In this study, the design methodology of pattern classification is introduced for avoiding faults through partial discharge occurring in the power facilities and local sites. In order to classify some partial discharge types according to the characteristics of each feature, the model is constructed by using the Radial Basis Function Neural Networks(RBFNNs) and Particle Swarm Optimization(PSO). In the input layer of the RBFNNs, the feature vector is searched and the dimension is reduced through Principal Component Analysis(PCA) and PSO. In the hidden layer, the fuzzy coefficients of the fuzzy clustering method(FCM) are tuned using PSO. Raw datasets for partial discharge are obtained through the Motor Insulation Monitoring System(MIMS) instrument using an Epoxy Mica Coupling(EMC) sensor. The preprocessed datasets for partial discharge are acquired through the Phase Resolved Partial Discharge Analysis(PRPDA) preprocessing algorithm to obtain partial discharge types such as void, corona, surface, and slot discharges. Also, when the amplitude size is considered as two types of both the maximum value and the average value in the process for extracting the preprocessed datasets, two different kinds of feature datasets are produced. In this study, the classification ratio between the proposed RBFNNs model and other classifiers is shown by using the two different kinds of feature datasets, and also we demonstrate the proposed model shows superiority from the viewpoint of classification performance.

Finite element modeling of contact between an elastic layer and two elastic quarter planes

  • Yaylaci, Murat;Avcar, Mehmet
    • Computers and Concrete
    • /
    • v.26 no.2
    • /
    • pp.107-114
    • /
    • 2020
  • In this study, a two dimensional model of receding contact problem has been analyzed using finite element method (FEM) based software ANSYS and ABAQUS. For this aim finite element modeling of elastic layer and two homogeneous, isotropic and symmetrical elastic quarter planes pressed by means of a rigid circular punch has been presented. Mass forces and friction are neglected in the solution. Since the problem is examined for the plane state, the thickness along the z-axis direction is taken as a unit. In order to check the accuracy of the present models, the obtained results are compared with the available results of the open literature as well as the results of two software are compared using Root Mean Square Error (RMSE) and good agreements are found. Numerical analyses are performed considering different values of the external load, rigid circular radius, quarter planes span length and material properties. The contact lengths and contact stresses of these values are examined, and their results are presented. Consequently, it is concluded that the considered non-dimensional quantities have noteworthy influence on the contact lengths and contact stress distributions, additionally if FEM analysis is used correctly, it can be an efficient alternative method to the analytical solutions that need time.

The Variations of Grounding Resistance of the Vertical Electrodes by Soil Models (대지구조 모델에 따른 봉형 접지전극의 접지저항값 변화)

  • Shim, Keon-Bo;Kim, Won-Bae;Seo, Gil-Mo;Cho, Geum-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.57-63
    • /
    • 2012
  • The basic purpose of grounding is for human safety and normal operation of system related to electrical shock hazard by faults of electrical equipments. A grounding electrode is defined as a conducting element that connects electrical systems and/or equipment to the earth. The lowest possible resistance connection to the earth is sought from the grounding electrode. The grounding electrode is the foundation of the electrical safety system. The resistance to ground of vertical electrodes buried in the two deference soil structures has been analyzed for a length of electrodes and soil parameters. The equation of ground resistance of vertical electrodes are Tagg's equation for uniform soil models, and modified equation of Dwight equation for two-layer soil model. In this paper, compared with results of two equations are calculated values of vertical electrode in uniform and two-layer soil models.

Evaluation of the Vibration Reduction Performance of a Cushioning Layer between Metal Blocks (금속 블록에 삽입된 감쇠층의 진동저감 성능 평가)

  • Yun, Seong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.7
    • /
    • pp.71-76
    • /
    • 2022
  • This study describes an evaluation of the vibration-level reduction effect of natural rubber inserted between two aluminum blocks, in which the modal parameters are predicted using two different damping systems. A numerical model with two degrees of freedom was established for both the cases. One was an eigenvalue problem analysis using a state space method and general viscous damping, whereas the other was a method using hysteretic damping. The modal parameters obtained from these two approaches were compared with those obtained from the finite element method using a commercial package. As a result, the natural frequencies observed in the complex frequency response curve were consistently less than the average of four percents. The damping ratios also showed good agreement within a reasonable range. However, the hysteretic damping system showed a relatively larger difference for all modal parameters. This suggests that the analysis procedure makes it easier to predict the vibration transmission characteristics of the shape and configuration of any cushioning layer.

Suggestions for Multi-Layer Planting Model in Seoul Area Based on a Cluster Analysis and Interspecific Association (식생 군집분석과 종간친화력 분석을 통한 서울형 다층구조 식재모델 제안)

  • Kim, Min-Kyung;Sim, Woo-Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.4
    • /
    • pp.106-127
    • /
    • 2010
  • Although multi-layer planting methods are more widely used as a method for clustered planting and environmental programs such as plant remediation, difficulties have been faced in applying those to planting design. This study develops a basic planting model that can be applied to multi-layer planting in basis on an analysis of forest structures in the Seoul area. An optimal number of clusters was determined through the ISA (Indicator Species Analysis), and 7 basic clusters were found through a cluster analysis by using PC ORD 4.0 software specifically developed for ecological analysis. The 7 basic clusters include the following communities: the Quercus acutissima Community, Sorbus alnifolia-Quercus mongolica Community, Pinus rigida-Pinus densifiora Community, Rododendron mucronulatum var. mucronulatum-Quercus mongolica Community, Juniperus rigida-Quercus mongolica Community, Rododendron mucronulatum var. mucronulatum-Pinus densiflora Community, and Rododendron sclippenbachii-Quercus mongolica Community. The study also selected 57 species with at least a 10% frequency among the plant species existing in the Seoul area and suggested both a companion species and available similar alternative species by conducting an additional interspecific association analysis. This study may help to enhance usefulness of the model in architectural planting design. In addition, the two results named above were synthesized to develop a multi-layer planting model that can be utilized in landscape planting design by selecting similar alternative species through the interspecific association analysis, which includes 7 clusters of natural plants. The multi-layer planting model can be widely applied to design planting because the model has an average target cover range based on the average value of a transformed likelihood.