Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • Win, Tint Soe;Tanaka, Toshihiko;Hiraki, Eiji;Okamoto, Masayuki;Lee, Seong Ryong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.176-183
    • /
    • 2014
  • Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

발전소에서 운전 중인 고전력 케이블의 절연저항의 변화를 감시하는 장치의 개발 (Development of Equipment Measuring Insulation Resistance of High-Power Cables in Operation at Power Station)

  • 엄기홍;김보경
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.159-164
    • /
    • 2016
  • 급증하고 있는 수요에 따른 고전력을 생산하기 위하여 발전소에서는 이에 대응하는 시설장비를 운영해야 한다. 규모는 점차 커지고, 기능이 다양해지고 있다. 발전소에서 불의가 사고가 발생하면 장비가 지장을 받게 되고, 막대한 경제적 손실 및 장애를 초래하게 된다. 사고 발생의 원인 중의 하나로서 케이블의 두 도체를 전기적으로 분리시키는 유전체의 기능이 약화되는 것이다. 케이블에 의한 사고를 미연에 방지하기 위하여 동작 상태를 감시 확인하여야 한다. 우리는 절연저항을 측정하기 위한 장비를 개발하여 서부발전(주)의 현장에 설치하여 운용 중이다. 변압기의 2차 측 와이(Y) 결선으로 연결된 모선은 생산된 전기를 외부 장치에 전송한다. 우리가 개발한 장비는 모선과 on/off 되는 케이블의 절연 저항을 측정하는 장비이다. 우리는 이 논문에서 하드웨어 구성을 위주로 우리가 개발한 장비를 소개한다.

JPEG 2000 Hard-wired Encoder를 위한 칼라 2-D DWT Processor의 구현 (The implementation of the color component 2-D DWT Processor for the JPEG 2000 hard-wired encoder)

  • 이성목;조성대;강봉순
    • 융합신호처리학회논문지
    • /
    • 제9권4호
    • /
    • pp.321-328
    • /
    • 2008
  • 본 논문에서는 차세대 정지영상 압축 표준 JPEG2000 CODEC의 Wavelet 변환부와 양자화기의 하드웨어 구조를 제안하고 선계하였다. 본 논문의 칼라 2-D DWT 프로세서는 JPEG 2000 Hard-wired Encoder에 적용하기 위해 제안하였다. JPEG 2000DWT(Discrete Wavelet Transform)에서는 Daubechies 9/7 filter를 사용하였고 2-B DWT의 변환과 복원과정에서의 오차가 ${\pm}1$LSB 이내로 들어갈 수 있게 설계하였다. 기존에 설계되었던 filter의 하드웨어 구조에서 하드웨어 복잡도를 높이는 곱셈기를 사용하지 않고 shift-and-adder 구조를 사용하였다. 이것은 DWT 변환에서 가장 많은 연산을 차지하는 filter의 동작 속도를 향상시킬 수 있으며 하드웨어 복잡도도 낮출 수 있다. 본 시스템은 표준화된 하드웨어 설계 언어인 Verilog-HDL을 사용하여 설계하였고, Synopsys사의 Design Analyzer와 TSMC $0.25{\mu}m$ ASIC Library를 사용하여 검증하였다.

  • PDF

최적 임펄스 전송을 위한 초광대역 테이퍼 슬롯 안테나 설계 (Design of UWB Tapered Slot Antenna for the Optimum Impulse Radio Transmitting & Receiving)

  • 고영목;나극환
    • 한국전자파학회논문지
    • /
    • 제21권6호
    • /
    • pp.553-563
    • /
    • 2010
  • 본 논문에서는 UWB 대역에서 최적 임펄스 신호 전송을 위한 테이퍼 슬롯 안테나(Tapered Slot Antenna: TSA) 설계에 대해 연구하였다. UWB 대역에서 동작하는 TSA는 end-fire 특성을 갖는 광대역 안테나로, 펄스 전송을 위한 IR-UWB(Impulse Radio Ultra-Wide Band) 시스템에 적합하다. 지향성 특성을 갖는 테이퍼 슬롯 안테나는 UWB 대역에서 손실이 적고, 임펄스 전송시 최소 에러를 가져야 한다. 전송되는 펄스 왜곡을 최소로 하기 위해 테이퍼 슬롯 안테나 급전부를 구성하는 광대역 임피던스 변환기와 microstrip/slotline 천이부 설계에 대해 연구하였으며, 설계된 테이퍼 슬롯 안테나에 대한 펄스 충실도는 전자기파에 대한 시간 영역 분석이 가능한 CST를 이용한 FDTD(Finite-Difference Time-Domain) 시뮬레이션과 펄스 상관식 유도를 통해 계산하였으며, 제작된 안테나에 대해 두 안테나를 0.5 미터 이격시킨 두 안테나 사이에서 약 93.89 % 정도의 양호한 결과를 얻을 수 있었다. 또한 chirp Z-변환 알고리즘을 유도를 통해, 나노초 이하의 펄스 신호에 대해 zoom-in 기능을 부여함으로써 펄스 신호에 대한 왜곡, 지연 및 분산 특성 등의 분석이 가능하다.

스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발 (Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator)

  • 이종훤
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

지하매설 및 해양 금속구조물 음극방식용 모듈 타입 스위칭 정류기 (Module-Type Switching Rectifier for Cathodic Protection of Underground and Maritime Metallic Constructions)

  • 문상호;김보경;김인동;노의철;권영원;정성우;임헌호
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.570-578
    • /
    • 2002
  • 음극방식은 지하매설 및 해양 금속 구조물의 부식을 방지하기 위해 가장 많이 사용되고 있는 방식법이다. 기존의 음극방식용 정류기는 SCR 위상제어 정류기로 구성되어 입련단 역율이 낮으며, 부피와 무게가 큰 단점을 지니고 있다. 본 논문에서는 이러한 문제를 해결하기 위해 새로운 음극방식용 모듈타입 스위칭 정류기를 제안한다. 제안한 정류기 회로는 크게 두 부분, 즉 한 대로 구성된 AC/DC 컨버터부와 네 대로 구성된 Module Ttpe DC/DC 컨버터부로 되어 있다. AC/DC 컨버터는 IGBT PWM Rectifier로서 입력전압의 역률을 거의 1로 제어하고 있으며 또한 DC Link 전압을 일정하게 제어하고 있다. Module Type DC/DC 컨버터는 ZCS/ZVS 스위칭 동작을 통하여 스위칭 손실 감소와 함께 고주파 동작을 가능하게 하여, 입력측과 출력측의 전기적 절연을 위한 변압기로 고주파 변압기를 사용할 수 있게 하였다. 이로 인해 시스템의 부피와 무게를 현저히 감소시켰다. 본 논문에서 개발한 방식용 정류기 기술은 다른 유사 분야에의 적용도 가능할 것으로 기대된다.

WiMAX 응용을 위한 결합 공진기 기반의 PCB 내장형 평형신호 듀플렉서의 설계 (Design of PCB Embedded Balanced-to-unbalanced WiMax Duplexer Using Coupled LC Resonators)

  • 박주용;박종철;박재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1587_1588
    • /
    • 2009
  • In this paper, PCB embedded balanced-to-unbalamced duplexer using coupled LC resonator was introduced for low cost dualband WiMax front-end-module application. In order to obtain the function of bandpass filter and balun transformer, proposed duplexer was configured by using magnetically coupled LC resonator. Out-of-band suppression was enhanced by applying two m-Derived transform circuits to obtain transmission zeros at 2GHz and 4.8GHz. In order to reduce the size of embedded duplexer, BaSrTiO3 (BST) composite high Dk RCC film was applied to improve the capacitance density. This high Dk film provided the capacitance density of 12.2 pF/mm2. The simulation results shows that fabricated duplexer had an insertion loss of 2.9dB and 5.5dB and return loss of 15dB and 16dB for 2.5GHz~2.6GHz and 3.5GHz~3.6GHz, respectively. The maximum magnitude and phase imbalance were 0.01dB and 0.17dB, and 1degree and 2degree in its passband, respectively. The out-of-band suppression was observed approximately 29dB and 40dB below 1.9GHz and over 4.5GHz, respectively. It has a volume of 6 mm $\times$ 7 mm $\times$ 0.7 mm (height).

  • PDF

하이브리드 수중 플라즈마 토치를 이용한 수처리 특성연구 (The Study of the Characteristics on Water Treatment Using Hybrid Water Plasma Torch)

  • 권순걸;이수호;조만철
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.138-143
    • /
    • 2006
  • 본 연구는 상용화에 관점에서 수처리용 플라즈마리액터를 제작하여 수처리 특성을 연구한 것으로, 본 연구에 사용된 하이브리드 수중 플라즈마 토치는 기존의 네온트랜스라는 저가의 전원을 사용한다는 측면에서 경제적으로 매우 우수하며 더불어 저전력용으로 제작되어 에너지 효율적 측면에서도 매우 우수하다. 특히 연구에 사용된 하이브리드 수중 플라즈마 토치는 두 종류의 플라즈마영역을 가지고 있어 각각의 영역의 장점을 물에 투입 할 수 있다는 특수한 장점을 가지고 있다. 이러한 하이브리드 수중 플라즈마 토치를 사용한 결과 얻은 다음과 같은 데이터(용존 오존(2.8[ppm]), 과산화수소(100[ppm]), 2[PH])는 살균에 매우 유용할만한 가치 있는 수치로서 실제 대장균 처리에 적용해본 결과 최대 10분 안에 대장균 완전 박멸이라는 매우 우수한 결과를 가질 수 있었다.

온도 및 절연체에 따른 케이블의 단선시간 특성 해석 (Fusing Time Characteristics Analysis of Cable according to Temperature and Insulator)

  • 김주희;강신동;김재호
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.15-20
    • /
    • 2018
  • This paper describes the fusing time characteristics of Light PVC Sheathed Circular Cord(VCTF) and Tray Frame Retardant(TFR) cables according to increased temperature under over current condition. The experimental equation will be used to determine the validity and reliability of the test results. The over current flowed 3, 5 and 10 times higher than the amount of allowable current using DC power supply with DAQ(Data Acquisition) measurement system. An infrared radiation heater, which was controlled by a variable AC auto transformer, was used to increase the temperature from room temperature to 50, 100 and 150 degrees Celsius. First, two type of cables were analyzed those with different cross-sectional areas with in the same structure and those with different structures with in the same cross-sectional areas. Then, it was determined how fusing time had been influenced according to the cross-sectional areas and different structures, respectively. The cable resistance was increased by joule heating according to increasing temperature. Therefore, the allowable current of cable is decreased. Finally, the fusing time of the cable was decreased due to increased temperatures at current flow, which were 3 times the amount of allowable current. The instantaneous breakdown was observed when current flow was 5 and 10 times over the amount of allowable current. The fusing time is directly affected by the structure of cable insulation.

ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계 (Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter)

  • 이득기;윤길문;차영길;김흥근
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.231-239
    • /
    • 1998
  • 본 논문에서는 대용량에 적합한 영전압 스위칭 전브리지 PWM 직류/직류 변한기의 동특성 해석과 제어 루프의 설계에 대해 논하였다. 전압을 제어하기 위한 위상전이제어의 효과와 영전압 스위칭을 위한 변압기의 누설인덕턴스, FET의 적합 커패시턴스의 이용효과를 고려한 소신호 모델을 유도하였다. 이 소신호 모델은 PWM 벅 변환기의 등가모델에 시비율 변조에 대한 두 개의 종속 전원을 추가함으로써 모델링할 수 있다. 소신호 해석 결과를 근거로 하여 2-극점, 1-영점 보상회로를 사용한 전압제어기를 설계하였다. 설계된 제어기의 타당성을 검증하기 위해서 개루프 시스템과 폐루프 시스템의 소신호 해석결과를 비교하였으며, 2kW급 부하실험으로 설계한 전압제어기의 동특성이 우수함을 실험적으로 입증하였다.