• 제목/요약/키워드: Two transformer

검색결과 552건 처리시간 0.025초

11차/13차 고조파를 동시에 제거하는 Single Tuned 필터 (A Study on the Performance Enhancement of HVDC System Using Hybrid Filter and Energy Recovery Filter)

  • 김찬기;양병모;정길조;안정식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.717-721
    • /
    • 2003
  • Two non-conventional HVDC converter arrangements are compared. These include the Capacitor Commutated Converter (CCC) in which series capacitors are included between the converter transformer and the valves, and the Controller Series Capacitor Converter (CSCC), based on more conventional topology, in which series capacitors are inserted between the AC filter bus and the AC network. Results show that both options have comparable steady state and transient performance. Danger of ferroresonance with the CSCC option is eliminated by controlling the amount of series compensation. The dynamic performance simulations is peformed by PSCAD/EMTDC

  • PDF

철도차량 보조전원용 Three-Level ZVZCS DC/DC 컨버터 (Three-Level ZVZCS DC/DC Converter using a Assistance Power Sources of the RailRoad Vehicles)

  • 노성찬;임응규;양성혁;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.880-885
    • /
    • 2003
  • Using a Assistance Power Sources of the Railroad Vehicles Three-Level ZVZCS DC/DC Converter is presented in this paper. The proposed three-Level DC/DC Converter Is to achieved zero voltage and zero current switching for the two Main switches. phase shift method is used a parastic capacitance by reverse recovery characteritics in a inner diode of the switching device. Also. using a diode second part of the Transformer by the simple auxiliary circuit for the achieved zero current switching of the Auxiliary switch. For the ZVZCS movement of the all switching devices is analyzed and verified under a 5kW, in the 100kHz switching frequency.

  • PDF

Novel Multiple Output Converter using Quasi Load

  • 최규식;현병철;이승운;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.125-126
    • /
    • 2010
  • In this paper, a novel multiple output converter using quasi load is proposed. Conventional multiple output converters using multi-winding transformer has poor output voltage regulations. To solve this problem, there are many proposals like post regulation method, weighted control method, and etc. However, the post regulation method regulates output voltage tightly but its conduction loss and cost are increased. And the weighted control can achieve high efficiency and low cost but its regulation is not enough. To solve these problems, this paper proposes a novel multiple output converter using quasi load. The proposed method uses a quasi load which acts like an active dummy load for tight regulation but there is rarely increase of loss and cost. The proposed method is verified by hardware test by two output(24V and 15V) flyback type converter.

  • PDF

벌크형 광 CT 센서 및 신호처리부 성능 개선 방안 연구 (A Study on Performance Improvement of Optical Current Transformer and Signal Processor)

  • 김영수;박병석;김명수;임용훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1929-1932
    • /
    • 2002
  • In this paper, some parameters are studied for the performance improvement of a bulk optical current sensor. The performance of optical current sensor is influenced by current measuring range, Verdet constant change due to temperature change, temperature variation of wave plate, signal to noise ratio of optical transmitter/receiver, optical bias mismatch. Two types of optical current sensors are implemented and tested in the current range from 10 ampere to 200 ampere.

  • PDF

LVDT 센서를 이용한 외경 측정 방안에 대한 연구 (A Study on the out-diameter measuring machine by the LVDT sensors)

  • 황정호;노지훈;박기홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.291-292
    • /
    • 2006
  • Currently A demand of high precision workpiece is increasing in industry. At present, roundness measuring machine using Air bearing, coordinate measuring machine that are used from measurement station. but these machines will not be able to apply to In-line process. because of like these machine's price are very expensive and measurement time is long. also, the complexity of conventional roundness measurement method based on fourier transform, it makes difficult to development analysis program. This work present new architecture of a Out-diameter measuring system fur analysis of roundness of product. In this system, the influence of table motion errors is minimize by using two LVDT sensor and knife edge contact tip. We are produce a test machine and make an experimenter on Out-diameter of test bearing. The measurement result compared with roundness measuring machine.

  • PDF

Modeling and Experimental Study of Radio-frequency Glow Discharges and Applications for Plasma Processing

  • Kang, Nam-Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.179-179
    • /
    • 2012
  • Low pressure radio-frequency glow discharges are investigated using theoretical modeling and various experimental diagnostic methods. In the calculations, global models and transformer models are developed to understand the chemical kinetics as well as the electrical properties such as the effective collision frequency, the heating mechanism and the power transferred to the plasma electrons. In addition, Boltzmann equation solver is used to compensate the effect of the electron energy distribution function (EEDF) shape in the global model, and the general expression of energy balance for non-Maxwellian electrons is developed. In the experiments, a number of traditional plasma diagnostic methods are used to compare with calculated results such as Langmuir probe, optical emission spectroscopy (OES), optical absorption spectroscopy (OAS) and two-photon absorption laser-induced fluorescence (TALIF). These theoretical and experimental methods are applied to understand several interesting phenomena in low pressure ICP discharges. The chemical and physical properties of low pressure ICP discharges are described and the applications of these methods are discussed.

  • PDF

전압, 무효전력 제어를 위한 전문가 시스템 (An Expert System for Voltage and Reactive Power Control)

  • 서승우;이흥재;박영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.852-854
    • /
    • 1988
  • An expert system is developed to solve the voltage problems occurring in electric transmission power system. It is based on knewledge engineering technique satisfies the performance criteria such as minimizing the number of operation of control device and quantity of reactive power. Also, it uses best-first search technique from the experts. Control devices used in this paper include shunt capaciter/reactor, transformer tap changer, generator output voltage and a generator is used after the availability of other two devices are checked.

  • PDF

Real-Time Identification and Estimation of Transformer Tap Ratios Containing Errors

  • Kim, Hongrae;Kwon, Hyung-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.109-113
    • /
    • 2002
  • This paper addresses the issue of parameter error identification and estimation in electric power systems. Parameter error identification and estimation is carried out as a part of the state estimation. A two stage estimation procedure is used to detect and identify parameter errors. Suspected parameters are identified by the WLAV state estimator in the first stage. A new WLAV state estimator adding suspected system parameters in the state vector is used to estimate the exact values of parameters. Supporting examples are given by using the IEEE 14 bus system.

3상 비대칭 정류회로의 PAM 방식을 이용한 고주파 저감법 (Reducing Harmonics of 3-Phase Asymmctic Recnher Current using a PAM mcthod)

  • 오훈;윤양웅;박현철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1995년도 추계학술발표회논문집
    • /
    • pp.105-109
    • /
    • 1995
  • In this paper, we persents a new PAM method without the input transformer for reducing harmonics in input AC line currents of converter. This system can reduce the harmonics like conventional 12-pulse converter. the dual bridge circuits are controlled with the shifted firing angle and connected 2 tap interphase reactor. the input current using 2 tap changing on interphase reactor is controlled with the different two values in order to make the input current waveform 12 pulses. The chracteristics of this system were confirmed through the computer simulation and the experiments.

  • PDF

AC 전압하에서 유리진공관의 방전현상 (Discharge Phenomena of Glass Tube Vacuum under AC Applied Voltage)

  • 최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.371-372
    • /
    • 2008
  • In this paper, we experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF