저손실 22.9 kV급 고온초전도 변압기를 위한 미니 모델 권선의 절연 설계 및 시험 연구 (A Study on Insulating Design and Test of Mini-Model windings for a 22.9 kV Class HTS Transformer Reducing AC Loss)

  • 백승명;천현권;류엔반둥;곽동순;이창화;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.94-99
    • /
    • 2004
  • This paper presents experimental data from model windings with different arrangement of coil in order to provide information to design a 22.9 kV class HTS transformer. Before experiment, the composite insulation of two different type of HTS transformers are investigated. The first basic of investigation is a breakdown characteristic of liquid nitrogen and flashover characteristic on the GFRP surface under ac and impulse, The second investigation is insulation design, manufacture and test of model windings. These include a AC withstand voltage test of 50 kV rms and a lighting impulse test of 150 kV at peak.

  • PDF

ANSI 규격에 의한 주상 변압기의 동압력 내력시험에 관한 연구 (The Study of the Design Tests for Current Capability according to ANSI)

  • 김선구;김원만;나대열;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.909-911
    • /
    • 2003
  • The almost pole transformers are constructed with tank, cover, clamp etc., that contains the insulation oil, core, coil, terminals, bus and the other accessories. If some fault current will be flown by some trouble or accident, interior pressure of the transformer shall be very quickly rise, and mechanical components or insulation oil from the transformer enclosure shall be propelled or dropped from the tank. For the prevention of the above accident, recently the pole transformers should be done 'the Design Tests for Fault Current Capability' according to ANSI C57.12.20(1997) There are two tests method in this standard, Test Number I with a high current arcing fault, without internal fusible elements, shall be conducted on rack enclosure with its minimum designed air space. Test Number II with an internal fusible element, shall be conducted on each enclosure diameter utilizing the internal fusible elements. KEPCO recently request to be done the 'Design Tests for Fault Current Capability' for pole transformers according to KEPCO's standard ES141-$533{\sim}545$, PS141-$482{\sim}518$ and RS141-$611{\sim}628$ that is same with Test Number I of ANSI C57.12.20.

  • PDF

전철 지중배전선로의 충전전류보상에 관한 연구 (A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway)

  • 김양수;장우진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

배터리 기반 2단 충전 9 kJ/s 고전압 충전기 설계 (Design of 9 kJ/s High Voltage LiPo Battery based 2-stage Capacitor Charger)

  • 조찬기;가재예;류홍제
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.268-272
    • /
    • 2019
  • A lithium polymer battery-based 9 kJ/s high-voltage capacitor charger, which comprises two stages, is proposed. A modified LCC resonant converter and resonant circuit are introduced at the first and second stages, respectively. In the first stage, the methods for handling low-voltage and high-current batteries are considered. Delta-wye three-phase transformers are used to generate a high output voltage through the difference between the phase and line-to-line voltages. Another method is placing the series resonant capacitor of the LCC resonant components on the transformer secondary side, which conducts considerably low current compared with the transformer primary side. On the basis of the stable operation of the first charging stage, the secondary charging stage generates final output voltage by using the resonance. This additional stage protects the rectifying diodes from the negative voltage when the output capacitor is discharged for a short time. The inductance and capacitance of the resonance components are selected by considering the resonance charging time. The design procedure for each stage with the aforementioned features is suggested, and its performance is verified by not only simulation but also experimental results.

새로운 CCM 단일 전력단 역률보상 풀 브리지 컨버터 (New CCM Single Stage PFC Full Bridge Converter)

  • 임창섭;권순걸;조정구;송두익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.986-989
    • /
    • 2002
  • This paper proposes a new single stage power factor correction (PFC) full bridge converter which operates at continuous conduction mode(CCM). The proposed single stage PFC consists of typical zero voltage switching(ZVS) full bridge DC/DC converter, two transformer auxiliary windings, and two small inductors, and two diodes. Neither additional active switch nor any control circuit are added for PFC resulting in very low cost. The proposed converter provides input power factor correction with CCM control and tight output voltage regulation. All switching devices are operated under ZVS with minimum voltage stress. Operation principle and analysis are explained and verified with computer simulation and experimental results on a 1.2kW, 100kHz prototype.

  • PDF

새로운 단일전력단 역률보상 풀브리지 컨버터 (New Single Stage PFC Full Bridge Converter)

  • 임창섭;권순걸;조정구;송두익
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.655-660
    • /
    • 2003
  • This paper proposes new single stage power factor correction (PFC) full bridge converter. The proposed converter is combined previous ZVS full bridge DC/DC converter with two inductors, two diodes, two magnetic coupling transformer for PFC. This process of power is isolated from the source and also regulate stable DC output voltage in a category. In this topology, the voltage stress of main switches is reduced by zero voltage switching. Moreover, the proposed converter doesn't need active PFC switch and auxiliarly circuits, like control and gating board, so it could decrease the size and cost and increase the efficiency.

직렬 연결된 두개의 트랜스포머를 갖는 새로운 위상천이 풀 브릿지 컨버터 (A New Phase Shift Full Bridge Converter with Serially Connected Two Transformers)

  • 구관본;김태성;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.370-373
    • /
    • 2002
  • A new phase shift full bridge converter(PSFB) with serially connected two transformers is proposed. It is well suited for applications in the communication equipment of a few hundred watts. The main features of the proposed converter are a wide input voltage range, an easiness to meet the requirement for zero voltage switching (ZVS) condition at a light load, and a small output voltage ripple. Furthermore, it features high power density since serially connected two transformers can replace both a main transformer and an output inductor. A mode analysis and experimental results are presented to verify the validity of the proposed converter.

  • PDF

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

고속전철 보조전원장치용 PWM 컨버터의 병렬운전에 관한 연구 (A Study on Parallel Operation of PWM Converter for Auxiliary Power Supply of High Speed Train)

  • 김연충;오근우;원충연;최종묵;기상우
    • 전자공학회논문지SC
    • /
    • 제37권6호
    • /
    • pp.64-72
    • /
    • 2000
  • 본 논문은 고속전철 보조전원장치에 사용되는 2대의 PWM 컨버터 병렬운전에 관하여 다루고 있다. 고역률을 이루고 변압기 1차측 전류 고조파 성분을 줄이기 위하여 3레벨 PWM 스위칭 방법에 의해 제어되는 AC/DC PWM 컨버터의 병렬운전을 제안하였다. 본 논문에서는 변압기의 결합효과를 제거하기 위한 제어기법과 컨버터 2대 사이의 위상전이기법 및 전원과 제어기를 동기화하기 위한 영점 검출방식을 나타내었다. TMS320C31 마이크로 프로세서와 10[kVA] PWM 컨버터로 구성된 축소시스템에 의한 실험 결과들은 제안된 알고리즘의 타당성을 보여주고 있다.

  • PDF

알킬 글리시딜에테르와 지방산의 축합반응 연구 (Study on the Condensation Reaction of Alkyl Glycidyl Ethers and Fatty Acids)

  • 김지현;황현아;이영석;이병민
    • 공업화학
    • /
    • 제23권4호
    • /
    • pp.416-420
    • /
    • 2012
  • 지방산 디에스테르 합성의 편리한 방법을 연구하였다. 긴 사슬 디에스테르는 천연윤활제와 절연유로서 많이 사용된다. 옥틸, 도데실, 헥사데실, 옥타데실 그리고 옥타-9-엔일 글리시딜 에테르 계열을 이러한 디에스터 구조를 합성하기 위해 사용하였다. 알킬 글리시딜에테르를 올레인산 그리고 옥타노익산과 같은 지방산과 반응시켰으며, one-step / two-step 축합반응을 비교하였다. 생성물인 1-O-acyl-2-O, 3-O-dioctadec-9-enoylglycerol은 $^{1}H-NMR$, FT-IR 그리고 HR/MS 스펙트럼을 통해 확인하였으며, 수율은 55~60%이었다.