• 제목/요약/키워드: Two transformer

검색결과 552건 처리시간 0.029초

트랜스포머 인코더와 시암넷 결합한 시맨틱 유사도 알고리즘 (Semantic Similarity Calculation based on Siamese TRAT)

  • 육성잠;조인휘
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2021년도 춘계학술발표대회
    • /
    • pp.397-400
    • /
    • 2021
  • To solve the problem that existing computing methods cannot adequately represent the semantic features of sentences, Siamese TRAT, a semantic feature extraction model based on Transformer encoder is proposed. The transformer model is used to fully extract the semantic information within sentences and carry out deep semantic coding for sentences. In addition, the interactive attention mechanism is introduced to extract the similar features of the association between two sentences, which makes the model better at capturing the important semantic information inside the sentence. As a result, it improves the semantic understanding and generalization ability of the model. The experimental results show that the proposed model can improve the accuracy significantly for the semantic similarity calculation task of English and Chinese, and is more effective than the existing methods.

A Medium-Voltage Matrix Converter Topology for Wind Power Conversion with Medium Frequency Transformers

  • Gu, Chunyang;Krishnamoorthy, Harish S.;Enjeti, Prasad N.;Zheng, Zedong;Li, Yongdong
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1166-1177
    • /
    • 2014
  • A new type of topology with medium-frequency-transformer (MFT) isolation for medium voltage wind power generation systems is proposed in this paper. This type of converter is a high density power conversion system, with high performance features suitable for next generation wind power systems in either on-shore or off-shore applications. The proposed topology employs single-phase cascaded multi-level AC-AC converters on the grid side and three phase matrix converters on the generator side, which are interfaced by medium frequency transformers. This avoids DC-Link electrolytic capacitors and/or resonant L-C components in the power flow path thereby improving the power density and system reliability. Several configurations are given to fit different applications. The modulation and control strategy has been detailed. As two important part of the whole system, a novel single phase AC-AC converter topology with its reliable six-step switching technique and a novel symmetrical 11-segment modulation strategy for two stage matrix converter (TSMC) is proposed at the special situation of medium frequency chopping. The validity of the proposed concept has been verified by simulation results and experiment waveforms from a scaled down laboratory prototype.

Wideband Double-Radiator Circular Disc Annular Monopole Antenna

  • Afoakwa, Samuel;Diawuo, Henry Abu;Jung, Young-Bae
    • Journal of information and communication convergence engineering
    • /
    • 제16권4호
    • /
    • pp.252-257
    • /
    • 2018
  • A wideband double radiator circular disc annular monopole antenna is proposed is this work. The radiators are etched on the surfaces of two Taconic TLY-5 substrates with a circular hole cut out of each of the radiators initially at the centers of the radiators with subsequent downward displacement of the holes. The antenna is designed with a two-step feeding transformer system for impedance matching between the input power source supplied by a $50-{\Omega}$ SMA connector and the monopole radiators. The transformer system improves the bandwidth performance at higher frequencies. The proposed antenna achieves a wideband having the capability of working between 0.645 and 18.775 GHz, corresponding to a -10 dB bandwidth of 186.7% with gain ranging from 0.95 to 8.26 dBi. In comparison to other metal disc planar monopole antennas, the proposed antenna has a small total size width due to the size of the ground plane, which has a diameter 100 mm. The frequency range of the antenna provides applications in global positioning systems, mobile communications, ultra-wideband short distance communications, and wireless computer networks.

양극성 DC 배전 시스템을 위한 고효율 전압 밸런싱 듀얼 액티브 브리지 컨버터 (High Efficiency Voltage Balancing Dual Active Bridge Converter for the Bipolar DC Distribution System)

  • 이민수;천성문;최동민;문건우
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.391-396
    • /
    • 2022
  • In this study, a new voltage-balancing dual-active bridge converter that integrates a DAB converter with a voltage balancer is proposed for a bipolar DC distribution system. The proposed converter is configured to connect two loads to the transformer secondary center tap of the DAB converter, and no additional components are added. The proposed converter has the same operation as the conventional DAB converter, and it makes both output voltages similar. Moreover, the imbalanced current offset between the two loads is bypassed only on the secondary side of the transformer. Consequently, the proposed converter integrates a voltage balancer without any additional components, and no additional loss occurs in the corresponding components. Thus, high efficiency and high power density can be achieved. The feasibility of the proposed converter is verified using 3 kW prototypes under 380 V input and 190/190 V output conditions.

Cycloconverter를 이용한 단상-3상 변환에 관한 연구 (Single Phase to 3 Phase Conversion Using Cyclo-Converter)

  • 박민호;전상대
    • 전기의세계
    • /
    • 제28권3호
    • /
    • pp.51-56
    • /
    • 1979
  • The purpose of this paper is to study the conversion of single phase to three phase. In the proceeding of phase conversion, it is very convinence to convert two-phase from single phase using cycloconverter before and then two to three phase by scott connection transformer. There are also systematized zero-crossing, mono vibrator and ring counter circuit for the gate trigger circuits of cycloconverter. The wave forms of three phase by experimental results are analyzed and discussed the relation of phase difference among them.

  • PDF

2차 권선을 직.병렬연결한 자속구속형 전류제한기의 퀜치특성 (Quench Characteristics of a Flux-lock type SFCL with Secondary Windings Connected in Serial and Parallel)

  • 박형민;조용선;최효상;오금곤;한태희;임성훈;황종선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.432-434
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) according to the number of the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of the transformer with a primary winding and two secondary windings connected in parallel, and the superconducting element was connected with secondary winding in series, respectively. The applied voltage at that tin was 200V. when two superconducting elements of the secondary winding was connected in parallel, the peak lie current increased up to 99A, while that flowing in a superconducting element in conventional flux-lock type SFCL showed 50A under the same conditions, the impedance of secondary winding under the same situation showed the opposite behavior. This enabled the parallel structure to be easy to increase the capacity of power system, in the meantime, The quench between two superconducting elements in the SFCL with two secondary windings connected in parallel was achieved simultaneously. While the quench-starting point was slightly different in the SFCL with two superconducting elements connected in series. We found that the parallel connection between the secondary windings increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

영산변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전 (Parallel Operation of Two Converters using Zero Current Transformer Method)

  • 송승찬;성제진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.256-264
    • /
    • 2000
  • In the conventional method, two CTs have been used to share the load current equally with two converters. A new simle method to find out the current difference between two converters using only one CT as a ZCT is suggested. Two experimental prototype converters were designed and implemented for the evaluation of the load current sharing. The results of experiment show that the newly proposed ZCT method using only one CT could make a good load current sharing than the conventional method required two CT when operating two converters in parallel.

  • PDF

배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석 (Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers)

  • 안정식;최순호;방정주;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

부가 정보를 활용한 비전 트랜스포머 기반의 추천시스템 (A Vision Transformer Based Recommender System Using Side Information)

  • 권유진;최민석;조윤호
    • 지능정보연구
    • /
    • 제28권3호
    • /
    • pp.119-137
    • /
    • 2022
  • 최근 추천 시스템 연구에서는 사용자와 아이템 간 상호 작용을 보다 잘 표현하고자 다양한 딥 러닝 모델을 적용하고 있다. ONCF(Outer product-based Neural Collaborative Filtering)는 사용자와 아이템의 행렬을 외적하고 합성곱 신경망을 거치는 구조로 2차원 상호작용 맵을 제작해 사용자와 아이템 간의 상호 작용을 더욱 잘 포착하고자 한 대표적인 딥러닝 기반 추천시스템이다. 하지만 합성곱 신경망을 이용하는 ONCF는 학습 데이터에 나타나지 않은 분포를 갖는 데이터의 경우 예측성능이 떨어지는 귀납적 편향을 가지는 한계가 있다. 본 연구에서는 먼저 NCF구조에 Transformer에 기반한 ViT(Vision Transformer)를 도입한 방법론을 제안한다. ViT는 NLP분야에서 주로 사용되던 트랜스포머를 이미지 분류에 적용하여 좋은 성과를 거둔 방법으로 귀납적 편향이 합성곱 신경망보다 약해 처음 보는 분포에도 robust한 특징이 있다. 다음으로, ONCF는 사용자와 아이템에 대한 단일 잠재 벡터를 사용하였지만 본 연구에서는 모델이 더욱 다채로운 표현을 학습하고 앙상블 효과도 얻기 위해 잠재 벡터를 여러 개 사용하여 채널을 구성한다. 마지막으로 ONCF와 달리 부가 정보(side information)를 추천에 반영할 수 있는 아키텍처를 제시한다. 단순한 입력 결합 방식을 활용하여 신경망에 부가 정보를 반영하는 기존 연구와 달리 본 연구에서는 독립적인 보조 분류기(auxiliary classifier)를 도입하여 추천 시스템에 부가정보를 보다 효율적으로 반영할 수 있도록 하였다. 결론적으로 본 논문에서는 ViT 의 적용, 임베딩 벡터의 채널화, 부가정보 분류기의 도입을 적용한 새로운 딥러닝 모델을 제안하였으며 실험 결과 ONCF보다 높은 성능을 보였다.

보조 스위치를 사용한 ZVS Two-Switch 포워드 컨버터에 대한 연구 (A Study of ZVS Two-Switch Forward Converter Using Auxiliary Switch)

  • 정민혁;김용;엄태민;이규훈;이동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.965_966
    • /
    • 2009
  • In this paper, a new soft-switching Two-switch Forward converter topology has been proposed. Compared with conventional two-switch forward converter, the proposed converter employs an auxiliary switch and a clamp capacitor to instead of two reset diodes, not only its duty cycle can exceed 0.5 to achieve wide range input voltage, but also soft switching can be achieved for all switches. Especially, voltage stress across main switches can be clamped at $1/2V_{in}$, voltage stress across auxiliary switch can be clamped at $V_{in}$. In addition, due to clamp capacitor series with the transformer, duty ratio can be extended with equation $V_o=\frac{V_{in}(1-D}D{N}$. Therefore, as a kind of better cost-effective approach, it is very attractive for high input, wide range and high efficiency application.

  • PDF