A New Family of Cascaded Transformer Six Switches Sub-Multilevel Inverter with Several Advantages

  • Banaei, M.R.;Salary, E.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1078-1085
    • /
    • 2013
  • This paper presents a novel topology for cascaded transformer sub-multilevel converter. Eachsub-multilevel converter consists of two DC voltage sources with six switches to achieve five-level voltage. The proposed topology results in reduction of DC voltage sources and switches number. Single phase low frequency transformers are used in proposed topology and voltage transformation and galvanic isolation between load and sources are given by transformers. This topology can operate as symmetric or asymmetric converter but in this paper we have focused on symmetric state. The operation and performance of the suggested multilevel converter has been verified by the simulation results of a single-phase nine-level multilevel converter using MATLAB/SIMULINK.

Interleaved Forward Converter for High Input Voltage Application with Common Active-Clamp Circuit

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.400-402
    • /
    • 2008
  • A new interleaved forward converter, adopting series-input parallel-output structure with a common transformer reset circuit, is proposed in this paper. Series-input structure distributes the voltage stress on switches, which makes it suitable for high input voltage application. Paralleling output stage with an interleaving technique enables the circuit handle large output current and reduces filter size. In addition, since two forward converters share one active-clamp circuit for the transformer reset, its primary structure is simplified. All these features make the proposed converter promising for high input voltage applications with high efficiency and simple structure.

  • PDF

리튬-이온 배터리 충방전 균등화를 위한 3-단자 양방향 모듈 회로 (A Three-Port Bidirectional Modular Circuit for Li-Ion Battery Strings Charge/Discharge Equalization Applications)

  • 이귀준;박남주;왕웅비;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.37-39
    • /
    • 2008
  • In this paper, a three-port bidirectional modular circuit applied in charging and discharging equalization for lithium-ion battery strings is proposed. This circuit consists of four MOSFETs and one transformer which provide a simple structure to be easily modularized. Compared to conventional individual cell equalization schemes, it utilizes the transformer as the energy transfer element, allowing direct transfer of energy between arbitrary two cells of three-cell battery module, thus improving the equalization efficiency significantly by using much less number of equalizers for long battery strings. Simulation results are presented to validate the circuit operation and confirm its capability to equalize the three-cell battery module.

  • PDF

새로운 위상변성 방법 (A New Method of Phase Transformation)

  • 오상세
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.38-41
    • /
    • 1964
  • This thesis is aimed to obtain efficiently economically any desired phases and single phase transformer without unbalance by using only a new transformer, applying the theory of rotating magnetic field. The brief construction and principle is as floow: two pieces of similar ring cores, triangular cores or polygonal cores are located on the upper and lower sides with equidistance. And the some number of similar leg cores, shaped a square-pillar or a sylinder, are arranged at equidistant of the core section. Ring windings or polyphase windings of AC machines are adopted as a winding method on the upper and lower cores. Three phase AC is applied to the primary windings on these cores so that the rotating magnetic field is induced on the cores and this magnetic fluxes pass through each of the secondary windings on the leg-cores with some difference in time.

  • PDF

새로운 변압기 보호용 디지털 계전 알고리즘 (A New Digital Relaying Algorithm for Transformer Protection)

  • 강용철;이병은;손진만;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.194-196
    • /
    • 2000
  • This paper presents a new digital relaying algorithm for protection of a two winding power transformer. The proposed algorithm calculates mutual flux linkages of primary and secondary windings from the currents and voltages of primary and secondary windings. The mutual flux linkage ratio of primary and secondary windings is equal to the turn ratio in case of the steady state and magnetic inrush. On the other hand, the ratio is different from the turn ratio in case of internal winding faults. The algorithm does not require B-H curve. The results of various tests are satisfactory.

  • PDF

저주파용 고전압 구형파 발생장치의 개발 (Development of high-voltage rectangu1ar waveform generator operating in low-frequency domain)

  • 이복희;최원규;장석훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.959-961
    • /
    • 1998
  • In this paper, we present design rule of high-voltage rectangular generator working in wide band frequency domain. Though power electronics now have voltage ratings up to several kV, it is difficult to design and fabricate high-voltage systems with the power electronic devices alone. So we have combined IGBT with technically designed transformer to get the high-voltage rectangular waveforms. In this work, next two things are the main factors. The first one is design of transformer working low-frequency domain of less than 10Hz. And the second one is adding offset voltage part. As a result, we can get variable frequency high-voltage rectangular waveform and this can be used as a voltage source of sandpaper manufacturing process.

  • PDF

Y-${\Delta}$ 변압기의 순환전류 추정방법 (Estimation of a circulating current of a three-phase Y-${\Delta}$ Transformer)

  • 강용철;이미선;이병은;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.363-365
    • /
    • 2006
  • This paper proposes an estimation method for a circulating current of a Y-${\Delta}$ Transformer. The delta winding current can be decomposed into the two components i.e. a non-circulating component and a circulating component. The former can be estimated using the line currents. However, the latter can not be estimated directly using the line currents. A first order differential equation for the circulating current is derived by applying the Kirchhoff's voltage law on the loop of the delta side. The circulating current can be estimated by the solving the differential equation. The performance of the proposed algorithm is investigated under various conditions including magnetic inrush and over-excitation. The algorithm can estimate the circulating current very accurately even under magnetic inrush and over-excitation.

  • PDF

가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가 (The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers)

  • 이병성;송일근;이재봉;한상옥
    • 한국전기전자재료학회논문지
    • /
    • 제16권12호
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

변압기 층간 절연지의 열열화 특성 평가에 관한 연구 (The Study on Characteristics for Thermal Aging of the Layer Insulation in Transformers)

  • 이병성;송일근;김동명;박동배;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.406-409
    • /
    • 2002
  • The primary insulation system used in an oil-filled transformer is Kraft paper, wood, porcelain and, of course, oil. Modern transformers use paper that is chemically treated to improve its tensile strength properties and resistance to aging caused by immersion in oil. These insulation papers are mainly aged to thermal stress. Over the course of the insulation paper and oil's life it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper using the layer insulation. We made two aging cell in which thermal aging tests of insulation papers and mineral oil are conducted. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

  • PDF

Surge arrester용 surge counter의 동작 특성 평가 (Operating characteristic of surge counter)

  • 김석수;최익순;조동환;이강섭;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1134-1137
    • /
    • 2004
  • The main function of surge counter is knowing the times of surge flowed in, which is installed under surge arrester. Two methods are presented in this paper to get the electric power for mechanical movement and detect the surge with surge counter. One is using ZnO varistor resister and the other is using the current transformer.