• Title/Summary/Keyword: Two transformer

Search Result 552, Processing Time 0.026 seconds

A Study on the Surface Corona Discharge in the Gas with different Mixing Ratio of Air to $SF_6$ ($SF_6$와 공기의 혼합기체중에서의 연면 코로나 방전)

  • 전춘생;조기선;우호환
    • 전기의세계
    • /
    • v.26 no.6
    • /
    • pp.78-85
    • /
    • 1977
  • This paper studies flashover voltage and surface corona loss of A.C and D.C in the mixed gas of air and SF$_{6}$ for solid insulators P.V.C, arcylic, glass and bakelite in two cases. In one case, those solids are covered with transformer oil and the other case, those solids are not covered with it. 1) The flashover voltage for each solids in SF$_{6}$ is more than three times compared with that in the air. The flashover voltage for P.V.C is the highest and then arcylic, glass, bakelite in a decreasing order. 2) The more the amount of SF$_{6}$ in the mixing ratio, the less corona loss. The P.V.C shows the least amount of corona loss and the bakelite the largest. 3) Compared with the corona loss of positive polarity and the negative polarity, the former has less corona loss than the latter. 4) The more the number of flashover discharge, the less insulation of each solids, but in case of bakelite, insulation almost vanishes after a couple of discharge. 5) When each insulator is covered with transformer oil, the flashover voltage generally increases and the corona loss decreases.eases.

  • PDF

Operation Characteristic and Harmonic Analysis of 200-MW Modulator (200-MW 모듈레이터의 동작 특성 및 고조파 해석)

  • Park, S.S.;Oh, J.S.;Cho, M.H.;NamKumg, W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

A Self-Driven Active Clamp Forward Converter Using the Auxiliary Winding of the Power Transformer (변압기 보조권선을 이용한 자기 구동 능동 클램프 포워드 컨버터)

  • 이광운;임범선;김희준
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.5
    • /
    • pp.350-354
    • /
    • 2003
  • This study proposes a new self-driven active clamp forward converter eliminating the extra drive circuit for the active clamp switch. The converter used the auxiliary winding of the power transformer to drive the active clamp switch and a simple R-C circuit to get the dead time between the two switches. The operation principle was presented and experimental results were used to verify theoretical predictions. A 100-W (5V/20A) prototype converter built that only exhibited 1.5-turn winding number in the auxiliary winding was sufficient to drive the active clamp switch on the input of 50V. Finally, the measured efficiency of the converter was presented and the maximum efficiency of 91% was obtained.

A New 19-level PWM Inverter for the Use of Stand-alone Photovoltaic Power Generation Systems (독립형 태양광 발전 시스템을 위한 새로운 19레벨 PWM 인버터)

  • 강필순;오석규;박성준
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.452-461
    • /
    • 2004
  • A novel multilevel PWM inverter is presented for the use of stand-alone photovoltaic power generation system. In appearance, it consists of three full-bridge modules and three cascaded transformers; therefore, the configuration of the proposed multilevel PW inverter is equal to that of a prior 11-level PWM inverter. Only the turn-ratio of a transformer and its corresponding switching function are different from each other. Owing to these differences, the proposed 19-level PWM inverter has two promising advantages. First, output voltage levels increase almost twofold. Consequently, it can generate more sinusoidal output voltage waveform. Second, due to a revised switching pattern, it lightens power imposed on the transformer, which is used for compensating output voltages with chopped pulses between steps. The validity of the proposed inverter system is verified by computer-aided simulations and experimental results based on a 1 [kW] prototype. The performance of the proposed 19-level PWM inverter is compared with the Prior 11-level PWM inverter and other counterparts.

DC Current Transducer Using Saturable Magnetic Cores (포화자성코어를 이용한 직류전류측정 트랜스듀서)

  • Park, Young-Tae;Jung, Jae-Kap;Gang, Jeon-Hong;Ryu, Kwon-Sang;Yu, Kwang-Min
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.138-142
    • /
    • 2004
  • Uncertainty and characteristics of the developed current sensor by means of two identically wound magnetic cores forming a ring like for measurement of a low DC current such as leakage current was described in this paper. This transducer consists of a sensor type of a current transformer, peak value detectors, a reference alternating low frequency voltage oscillator, precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC current. The resolution and sensitivity of the sensor were 0.1㎃ and 10㎷/㎃, respectively.

A Novel Soft-Switching PWM DC/DC Converter with DC Rail Series Switch-Parallel Capacitor Edge Resonant Snubber Assisted by High-Frequency Transformer Parasitic Components

  • Fathy, Khairy;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.377-382
    • /
    • 2005
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. One topology of proposed DC-DC converters is composed of a typical voltage source-fed full-bridge high frequency PWM inverter using DC busline side series power semiconductor switching devices with the aid of a parallel capacitive lossless snubber. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. It is proved that the more the switching frequency of full-bridge soft switching inverter increases, the more soft-switching PWM DC-DC converter with a hish frequency transformer link has remarkable advantages for its efficiency and power density as compared with the conventional hard-switching PWM inverter type DC-DC converter

  • PDF

Design of Inverter for Driving the Multi-lamp using an Piezoelectric Transformers (압전 변압기를 이용한 멀티 램프 구동용 인버터 설계)

  • Cho Sung-Koo;Lim Young-Cheol;Yang Seung-Hak
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.130-137
    • /
    • 2005
  • LCD needs a backlight that is a light source as a photodetector that has a light modulation function and CCFL is used usually. Inverter that composes using existent winding transformer operates multi lamps, however, this efficiency falls by losses of core or winding and volume or weight increases or there is danger of fire by overheating. In order to solve these problems, a multi lamp driving Inverter using PT is composed according to the design guideline in this paper. We conformed whether the multi lamp drive method using EEFL that a current burden is less in applicable to piezoelectric inverter, and used the method that connect two piezoelectric transformers by parallel to an inverter.

3-D Analysis of Temperature Distribution in Transformers (변압기의 3차원 온도분포 해석)

  • 오연호;송기동;선종호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.9
    • /
    • pp.434-441
    • /
    • 2003
  • This paper deals with the temperature characteristics according to the cooling medium and the duct size in model transformers. For the analysis and the temperature-rise tests, two 400kVA model transformers have been manufactured. One has been filled with the alpha oil as the cooling medium and constructed the duct sizes of $3\textrm{mm}$ and $5\textrm{mm}$ in the low-voltage and high-voltage windings respectively. The other has been filled the beta oil and the duct sizes were $4\textrm{mm}$ and $6\textrm{mm}$. The temperature-rise tests have been performed by the back-to-back method and the load factor has been controlled the range of 90%∼130%. The temperature values have been measured by the thermocouple and from the sixteen points in each transformer. A commercial CFD program "FLUENT" has been used for the analysis of temperature distribution. The geometry of transformer has been modeled to 3-dimensional by using the hybrid calculation mesh including the radiator. And also, the natural convection velocity has been measured at the oil top position, and compared with the calculated results.

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

An auxiliary circuit for reducing loss during free-wheeling interval in FB ZVT PWM converter (FB ZVT PWM 컨버터의 환류구간 손실저감을 위한 보조회로)

  • 윤창선;김병철;김광헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.209-214
    • /
    • 2000
  • In this paper, we propose a FB ZVT(full bridge zero voltage transition) PWM OC~OC converter which uses a a saturable reactor, instead of two additional switches, to achieve zero voltage switching. The conventional h high frequency phase shifted FB ZVT PWM OC-OC converter has a disadvantage that a circulating current f flows through high frequency transformer and switching devices during the free-wheeling interval. Due to this c circulating current, conduction loss increases. In order to reduce such the loss as this, we propose circuit of r reducing conduction loss at the secondary side of transformer. The operation principles are explained in detail a and the several interesting simulations and experimental results verify the validity of the proposed circuit.

  • PDF