• Title/Summary/Keyword: Two transformer

Search Result 552, Processing Time 0.023 seconds

Performance Comparison Study on LFLP and DBLP Daylighting System (LFLP와 DBLP 자연채광시스템의 성능평가 비교 연구)

  • Choi, Jeon-Yong;Kang, Eun-Chul;Lee, Euy-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.799-804
    • /
    • 2011
  • The LFLP (Linear Fresnel Light Pipe) system uses a linear Fresnel lens to follow the sun and concentrates the parallel sunlight into a line. A LFLP daylighting system has been developed and updated to a DBLP (Double Blind Light Pipe) daylighting system to improve the overall system efficiency in the morning and afternoon. The new design consists of a double-blind style with a cone-shaped light transformer. The blinds are used to collect the sun's altitude and azimuth movements through the day. Behind the two sets of blinds is the light transformer, which is based on a parabolic-shaped light concentrator. The light transformer is designed to efficiently deliver light within a thirty-degree radial spread so that the light pipe can internally reflect the light. The results of scale-model tests are encouraging, and the efficiency is three times higher than that of the previous LFLP system.

Applied Sound Frequency Monitoring in the Transformer Oil Using Fiber Optic Sagnac Interferometer (사냑형 간섭계 광섬유 센서를 이용한 변압기유 내에서의 외부 음향 주파수 모니터링)

  • Lee, Jongkil;Lee, Seunghong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.288-294
    • /
    • 2015
  • The fiber optic Sagnac interferometer is well established as a sensor for detection of physical perturbations such as acoustic and vibration. In this paper acoustic signals generated in the cylindrical cavity submerged in transformer oil were measured by the fiber optic sensor array in one Sagnac loop. Two different external sound frequencies, $f_1$ and $f_2$, were applied to the sensor array simultaneously by using piezoelectric with frequency range from 5 kHz to 90 kHz. Based on the experimental results, fiber optic sensor detected harmonic series of applied sound frequency such as $f_1$, $f_2$, $2f_1$, $2f_2$, ${\mid}f_1-f_2{\mid}$, ${\mid}f_1+f_2{\mid}$. Suggested fiber optic sensor array can be applied to monitor physical quantities such as internal sound pressure and vibration due to partial discharge in the real electric transformer system.

Method to Prevent the Malfunction Caused by the Transformer Magnetizing Inrush Current using IEC 61850-based IEDs and Dynamic Performance Test using RTDS Test-bed

  • Kang, Hae-Gweon;Song, Un-Sig;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1104-1111
    • /
    • 2014
  • The digital substations are being built based on the IEC 61850 network. The cooperation and protection of power system are becoming more intelligent and reliable in the environment of digital substation. This paper proposes a novel method to prevent the malfunction caused by the Transformer Magnetizing Inrush Current(TMIC) using the IEC 61850 based data sharing between the IEDs. To protect a main transformer, the current differential protection(87T) and over-current protection(50/51) are used generally. The 87T IED applies to the second harmonic blocking method to prevent the malfunction caused by the TMIC. However, the 50/51 IED may malfunction caused by the TMIC. To solve that problem, the proposed method uses a GOOSE inter-lock signal between two IEDs. The 87T IED transmits a blocking GOOSE signal to the 50/51 IED, when the TMIC is detected. The proposed method can make a cooperation of digital substation protection system more intelligent. To verify the performance of proposed method, this paper performs the real time test using the RTDS (Real Time Digital Simulator) test-bed. Using the RTDS, the power system transients are simulated, and the TMIC is generated. The performance of proposed method is verified in real-time using that actual current signals. The reaction of simulated power system responding to the operation of IEDs can be also confirmed.

Application of Water Mist System for a Power Transformer Room - Fire Extinguishment(Part 1) (변압기실 화재에 대한 미분무수 소화시스템의 적용 - 소화특성을 중심으로(Part 1))

  • Han Yong-Shik;Choi Byung-Il;Kim Myung-Bae
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.32-36
    • /
    • 2005
  • A water mist system was considered as a possible alternative to a gaseous suppression system that can not prevent re-ignition after fire extinguishment for a power transformer room. This study deals with the fire suppression capability of the water mist systems. High-and low-pressure water mist systems were examined to compare efficiency of both systems. The power transformer examined in this study occupied about $7\%$ of a $10m\times10m\times$ transformer room. Full-scale suppression tests were performed for six different fire scenarios: two spray fires, three pool fires and one cascade fire. The fire suppression test results demonstrated that the high-pressure system was superior to the low-pressure system, especially considering oxygen depletion and the ambient temperature distribution.

A Korean speech recognition based on conformer (콘포머 기반 한국어 음성인식)

  • Koo, Myoung-Wan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.5
    • /
    • pp.488-495
    • /
    • 2021
  • We propose a speech recognition system based on conformer. Conformer is known to be convolution-augmented transformer, which combines transfer model for capturing global information with Convolution Neural Network (CNN) for exploiting local feature effectively. The baseline system is developed to be a transfer-based speech recognition using Long Short-Term Memory (LSTM)-based language model. The proposed system is a system which uses conformer instead of transformer with transformer-based language model. When Electronics and Telecommunications Research Institute (ETRI) speech corpus in AI-Hub is used for our evaluation, the proposed system yields 5.7 % of Character Error Rate (CER) while the baseline system results in 11.8 % of CER. Even though speech corpus is extended into other domain of AI-hub such as NHNdiguest speech corpus, the proposed system makes a robust performance for two domains. Throughout those experiments, we can prove a validation of the proposed system.

Unsupervised Transfer Learning for Plant Anomaly Recognition

  • Xu, Mingle;Yoon, Sook;Lee, Jaesu;Park, Dong Sun
    • Smart Media Journal
    • /
    • v.11 no.4
    • /
    • pp.30-37
    • /
    • 2022
  • Disease threatens plant growth and recognizing the type of disease is essential to making a remedy. In recent years, deep learning has witnessed a significant improvement for this task, however, a large volume of labeled images is one of the requirements to get decent performance. But annotated images are difficult and expensive to obtain in the agricultural field. Therefore, designing an efficient and effective strategy is one of the challenges in this area with few labeled data. Transfer learning, assuming taking knowledge from a source domain to a target domain, is borrowed to address this issue and observed comparable results. However, current transfer learning strategies can be regarded as a supervised method as it hypothesizes that there are many labeled images in a source domain. In contrast, unsupervised transfer learning, using only images in a source domain, gives more convenience as collecting images is much easier than annotating. In this paper, we leverage unsupervised transfer learning to perform plant disease recognition, by which we achieve a better performance than supervised transfer learning in many cases. Besides, a vision transformer with a bigger model capacity than convolution is utilized to have a better-pretrained feature space. With the vision transformer-based unsupervised transfer learning, we achieve better results than current works in two datasets. Especially, we obtain 97.3% accuracy with only 30 training images for each class in the Plant Village dataset. We hope that our work can encourage the community to pay attention to vision transformer-based unsupervised transfer learning in the agricultural field when with few labeled images.

Broadband power amplifier design utilizing RF transformer (RF 트랜스포머를 사용한 광대역 전력증폭기 설계)

  • Kim, Ukhyun;Woo, Jewook;Jeon, Jooyoung
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.456-461
    • /
    • 2022
  • In this paper, a two-stage single-ended power amplifier (PA) with broadband gain characteristics was presented by utilizing a radio frequency (RF) transformer (TF), which is essential for a differential amplifier. The bandwidth of a PA can be improved by designing TF to have broadband characteristics and then applying it to the inter-stage matching network (IMN) of a PA. For broadband gain characteristics while maintaining the performance and area of the existing PA, an IMN was implemented on an monolithic microwave integrated circuit (MMIC) and a multi-layer printed circuit board (PCB), and the simulation results were compared. As a result of simulating the PA module designed using InGaP/GaAs HBT model, it has been confirmed that the PA employing the proposed design method has an improved fractional bandwidth of 19.8% at a center frequency of 3.3GHz, while the conventional PA showed that of 11.2%.

A study on the Measurement of Residual Flux for Transformer (변압기 잔류자속 측정에 관한 연구)

  • Kim, Young-Hak
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.5
    • /
    • pp.133-138
    • /
    • 2022
  • In previous studies to obtain the residual magnetic flux of the transformer using the leakage magnetic flux, a transfer function was used. The transfer function was consisted with the leakage magnetic flux measured outside the transformer and the residual magnetic flux measured at the moment passing through the two ± residual points. In this study, a method of calculating the ratio of the maximum operating leakage flux to the residual leakage flux was proposed The advantage of this method is to avoid the uncertainty of the transfer function due to current noise. Then, the noise of the sensor was measured to investigate the effect of the drift of the noise on the measurement results. Comparing the residual leakage magnetic flux density with 80nT of the drift noise, 66 times or more at a distance of 10 mm and 5 times or more at a distance of 100 mm were obtained. 100mm was the maximum measurement distance to obtain the residual magnetic flux.

Design of A Microwave Planar Broadband Power Divider (마이크로파대 평면형 광대역 전력 분배기 설계)

  • Park, Jun-Seok;Kim, hyeong-Seok;Ahn, Dal;Kang, Kwang-yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.651-658
    • /
    • 2001
  • A novel multi-section power divider configuration is proposed to obtain wide-band frequency performance up to microwave frequency region. Design procedures for the proposed microwave broadband power divider are composed of a planar multi-section three-ports hybrid and a waveguide transformer design procedures. The multi-section power divider is based on design theory of the optimum quarter-wave transformer. Furthermore, in order to obtain the broadband isolation performance between the two adjacent output ports, the odd mode equivalent circuit should be matched by using the lossy element such as resistor. The derived design formula for calculating these odd mode matching elements is based on the singly terminated filter design theory. The waveguide transformer section is designed to suppress the propagation of the higher order modes such as waveguide modes due to employing the metallic electric wall. Thus, each section of the designed waveguide transformer should be operated with evanescent mode over the whole design frequency band of the proposed microwave broadband power divider. This paper presents several simulations and experimental results of multi-section power divider to show validity of the proposed microwave broadband power divider configuration. Simulation and experiment show excellent performance of multi section power divider.

  • PDF

Analysis of AC Electric Railway System using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 교류 전철급전시스템 해석)

  • Lee, Han-Min;Han, Moon-Seob;Chang, Sang-Hoon;Oh, Kwang-Hae;Lee, Chang-Mu;Kim, Joo-Rak
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1241-1243
    • /
    • 2002
  • This study presents a AC electric railway system analysis using PSCAD/EMTDC for circuit analysis and fault studies. This PSCAD/EMTDC model includes feeder, contact line, rails. Scott-transformer. Auto-transformer and so on. This model is based on four-port network which is an extension of two-port network theory. In order to verify the proposed model, fault studies of a test system are performed.

  • PDF