• 제목/요약/키워드: Two stage operation

검색결과 571건 처리시간 0.051초

넓은 충전 범위를 갖는 전기 자동차용 급속 충전기의 고효율 운전을 위한 손실 분석 (Power Loss Analysis of EV Fast Charger with Wide Charging Voltage Range for High Efficiency Operation)

  • 김대중;박진혁;이교범
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1055-1063
    • /
    • 2014
  • Power losses of a 1-stage DC-DC converter and 2-stage DC-DC converter are compared in this paper. A phase-shift full-bridge DC-DC converter is considered as 1-stage topology. This topology has disadvantages in the stress of rectifier diodes because of the resonance between the leakage inductor of the transformer and the junction capacitor of the rectifier diode. 2-stage topology is composed of an LLC resonant full-bridge DC-DC converter and buck converter. The LLC resonant full-bridge DC-DC converter does not need an RC snubber circuit of the rectifier diode. However, there is the drawback that the switching loss of the buck converter is large due to the hard switching operation. To reduce the switching loss of the buck converter, SiC MOSFET is used. This paper analyzes and compares power losses of two topologies considering temperature condition. The validity of the power loss analysis and calculation is verified by a PSIM simulation model.

나노 환경입자 측정용 전기적 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of Electrical Impactor for Nano Environmental Aerosols)

  • 지준호;조명훈;배귀남;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1417-1422
    • /
    • 2003
  • An electrical cascade impactor is a multistage impaction device to separate airborne particles into aerodynamic size classes using electrical method. We designed a real-time three-stage electrical low-pressure impactor, which is proper to nanometer sized environmental aerosols. Performance evaluation was carried out for stage 1 and 2. The monodisperse liquid dioctyl sebacate (DOS) particles were generated using condensation-evaporation followed by electrostatic classification using DMA (differential mobility analizer) for particles with diameters in the range of $0.04{\sim}0.8{\mu}m$. The evaluation of the electrical impactor is based on the use of two electrometers, one connected to the impaction plate of the impactor, and the other to the faraday cage as backup filter. The results showed that the experimental 50% cutoff diameters in the operation pressure were 0.53 and $0.12{\mu}m$ for stage 1 and stage 2. The effect of operation pressure on the cutoff diameter and the steepness of collection effcieicy curves is investigated.

  • PDF

An Experimental Investigation of the G-M type Pulse Tube Refrigerator

  • Park, Seong-Je;Koh, Deuk-Yong;Yeom, Han-Kil;Hong, Yong-Ju;Kim, Hyo-Bong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.40-45
    • /
    • 2004
  • The experimental results of the G-M (Gifford-McMahon) type pulse tube refrigerators are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The objectives of this study are to develop the design technology of the G-M type pulse tube refrigerator and acquire its application methods for replacing G-M cryocooler. As a preliminary test, the refrigeration performances of the basic, orifice, and double inlet pulse tube refrigerators were investigated. The lowest temperature obtained in the one-stage pulse tube refrigerator was 34.4K and the refrigeration capacity at the optimum operation condition was 23W at 80K. And the lowest temperature of the second stage cold head in the two-stage pulse tube refrigerators was 18.3K and the refrigeration capacities at optimum condition were 0.45W at 20K and 20W at 80K, respectively. Finally, the lowest temperature obtained in the three-stage pulse tube refrigerator was 29.8K and the refrigeration capacity at the optimum operation condition was 1.3W for 40K and 5W for 70K.

Mixed CT/DT Cascaded Sigma-Delta Modulator

  • Lee, Kye-Shin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권4호
    • /
    • pp.233-239
    • /
    • 2009
  • A mixed CT/DT 2-1 cascaded ${\Sigma\Delta}M$ which includes a first stage CT ${\Sigma\Delta}M$ and a second stage mismatch insensitive two-channel time-interleaved DT ${\Sigma\Delta}M$ is proposed. With this approach, the advantages of both CT and DT ${\Sigma\Delta}Ms$ including high speed operation, inherent anti-aliasing filter, and good coefficient matching can be achieved. The two-channel time-interleaved ${\Sigma\Delta}M$ used in the second stage alleviates the speed constraints of the DT ${\Sigma\Delta}M$, whereas enables better matching between the analog and digital filter coefficients compared to CT ${\Sigma\Delta}Ms$.

전단일전력단을 갖는 고역율 형광등용 전자식 안정기 구현 (Implementation of a High-Power-Factor Single-Stage Electronic Bal last for fluorescent lamps)

  • 서철식;박재욱;김해준;노채균;김동희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.123-127
    • /
    • 2001
  • In this paper, prototype high-power-factor single-stage electronic ballast for fluorescent lamps is designed and implemented. A new low cost single stage high power factor electronic ballast for fluorescent lamps is based on integration of two-boost converter and LC type high frequency resonant converter. A ballast is obtained by simple construction, because full bridge rectifier diode is eliminated and simple control circuit is applied. Using two boost converter operating positive and negative half cycle respectively at line frequency (60Hz), operation in discontinuous conduction mode performs high power factor. The experimental results Show the good performance as PF 0.99, $A_{THD}$ 15.4%, and CF 1.65 at Output 63.5W.W.

  • PDF

저온수열원이용 열펌프시스템의 전처리 및 성능분석 (Performance Analysis and Prior-Treatment of Heat Pump System with Low-Temperature Water Heat Source)

  • 박성룡;장기창;이상남;라호상;박준택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.258-263
    • /
    • 2000
  • River water is higher in temperature than the surrounding environment during the winter. It is highly suitable a heat source for heat pump system. Despite its suitability, however, it is not widely used, due to its fouling and corrosive nature in heat exchanger tubes of evaporator. It is designed prior-treatment system which come into direct contact with the river water, such as auto-seamer, ozone generator for bactericidal test and auto-cleaning system. And it is analyzed treatment effects for its operation. It is designed two-stage compression heat pump system using R-134a with heating load 35.16kW, ad analyzed its performance. As a result it is obtained 3.08 COP when mid-point pressure is 1,200kPa, and bypass ratio of flowing refreigerant to high-stage compressor is 25.1%

  • PDF

약년자 [40세 미만] 폐암 수술증례의 임상적인 검토 (Clinical Evaluation of Lung Cancer in Patients Younger Than 40 Years)

  • 문준호
    • Journal of Chest Surgery
    • /
    • 제26권11호
    • /
    • pp.861-865
    • /
    • 1993
  • The lung cancer in patients under 40 years old is rare and reported to be more rapidly fatal than in older persons. We reviewed the records of 18 cases who younger than 40 years with histologically proven lung cancer between 1959 and 1992 at department of Thoracic Surgery in National Medical Center. There were 12 male and 6 female patients. Two male and all female patients had never smoked. The 17 cases had respiratory symptoms for a mean duration of 3 months. The squamous carcinoma was found in 7 cases[38.9%], small cell carcinoma in 4 cases[22.2%], mixed cell carcinoma in 4 cases[22.2%], adenocarcinoma in 2 cases[11.1%] and bronchoalveolar cell carcinoma in 1 case. Among the 6 resected tumors, one case was stage I, two cases were stage II and three cases were stage IIIa. The operation was considered complete and curative in 6 patients and noncurative in 6 pations because of an exploratory thoracotomy. We conclude that lung cancer in young persons is virulent and that diagnosis is frequently delayed.

  • PDF

A Comparative Study of Simple Ac-Dc PWM Full-Bridge Current-Fed and Voltage-Fed Converters

  • Moschopoulos Gerry;Shah Jayesh
    • Journal of Power Electronics
    • /
    • 제4권4호
    • /
    • pp.246-255
    • /
    • 2004
  • Ac-dc PWM single-stage converters that integrate the PFC and dc-dc conversion functions in a single switching converter have been proposed to try to minimize the cost and complexity associated with implementing two separate and independent switch-mode converters. In this paper, two simple ac-dc single-stage PWM full-bridge converters are considered - one current-fed, the other voltage-fed. The operation of both converters is explained and their properties are noted. Experimental results obtained from simple lab prototypes of both converters are presented, then compared and discussed.

부품외주를 고려한 조립형 Flowshop 일정계획문제 연구 (An Assembly-Type Flowshop Scheduling Problem with Outsourcing Allowed)

  • 전재호
    • 산업경영시스템학회지
    • /
    • 제29권4호
    • /
    • pp.34-42
    • /
    • 2006
  • This paper considers an assembly-type flowshop scheduling problem in which each job is assembled with two types of components. One type of the components is outsourced with positive lead time but the other type is fabricated in-house at the first stage. The two types of the components should be prepared at the first stage before starting the assembly operation for each job at the second stage. The objective is to schedule the jobs so that the makespan is minimized. Some solution properties and lower bounds are derived and incorporated into a branch and bound algorithm. Also, an efficient heuristic is developed. The performances of the proposed branch and bound algorithm and heuristic are evaluated through computational experiments.

특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성 (Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines)

  • 심서현;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.