• Title/Summary/Keyword: Two stage operation

Search Result 572, Processing Time 0.022 seconds

Single Stage Power Factor Correction Using A New Zero-Voltage-Transition Isolated Full Bridge PWM Boost Converter

  • Jeong, Chang.-Y.;Cho, Jung-G.;Baek, Ju-W.;Song, Du-I.;Yoo, Dong-W.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.694-700
    • /
    • 1998
  • A novel zero-voltage-transition (ZVT) isolated PWM boost converter for single stage power factor correction (PFC) is presented to improve the performance of the previously presented ZVT converter[8]. A simple auxiliary circuit which includes only one active switch provides zero-voltage-switching (ZVS) condition to all semiconductor devices. (Two active switches are required for the previous ZVT converter) This leads to reduced cost and simplified control circuit comparing to the previous ZVT converter. The ZVS is achieved for wide line and load ranges with minimum device voltage and current stresses. Operation principle, control strategy and features of the proposed converter are presented and verified by the experimental results from a 1.5 kW, 100 KHz laboratory prototype.

  • PDF

Financial Application of Time Series Prediction based on Genetic Programming

  • Yoshihara, Ikuo;Aoyama, Tomoo;Yasunaga, Moritoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.524-524
    • /
    • 2000
  • We have been developing a method to build one-step-ahead prediction models for time series using genetic programming (GP). Our model building method consists of two stages. In the first stage, functional forms of the models are inherited from their parent models through crossover operation of GP. In the second stage, the parameters of the newborn model arc optimized based on an iterative method just like the back propagation. The proposed method has been applied to various kinds of time series problems. An application to the seismic ground motion was presented in the KACC'99, and since then the method has been improved in many aspects, for example, additions of new node functions, improvements of the node functions, and new exploitations of many kinds of mutation operators. The new ideas and trials enhance the ability to generate effective and complicated models and reduce CPU time. Today, we will present a couple of financial applications, espc:cially focusing on gold price prediction in Tokyo market.

  • PDF

Study on the Vibration Control Using Balance Weight for W/V-type Air Compressor (W/V형 공기압축기의 불평형진동 저감에 관한연구)

  • 정하돈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.686-692
    • /
    • 1999
  • For the purpose of increasing compressed air pressure higher than 30bar lightening weight and decreasing installation area of air compressor used for shipboard and industrial power plant it is necessary to arrange its cylinders as a w-type or v-type construction multi-stage compression pro-cess more than two stages and to increase its operation speed higher than 1200rpm In this recip-rocating type air compressor operated in high speed having a crank mechanism and complicate cylinder arrangement there is a vibration problems which can be solved by balancing its recipro-cating parts with balance weight and approriate arranging of cylinder's arrangement angles.

  • PDF

A New Cost-Effective Current-Balancing Multi-Channel LED Driver for a Large Screen LCD Backlight Units

  • Hong, Sung-Soo;Lee, Sang-Hyun;Cho, Sang-Ho;Roh, Chung-Wook;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.351-356
    • /
    • 2010
  • A new current-balancing multi-channel LED driver is proposed in this paper. The conventional LED driver system consists of three cascaded power conversion stages and its driver stage has the same number of expensive boost converters as those of the LED channels. On the other hand, the proposed LED driver system consists of two cascaded power stages and its driver stage requires only passive devices instead of expensive boost converters. Nevertheless, all of the currents through multi-channel LEDs can be well balanced. Therefore, it features a smaller system size, improved efficiency, and lower cost. To confirm the validity of the proposed driver, its operation and performance are verified on a prototype for a 46" LCD TV.

High Power 1.83 GHz Femtosecond Yb-doped Fiber Laser Incorporating Repetition Rate Multipliers

  • In Chul Park;Eun Kyung Park;Ye Jin Oh;Hoon Jeong;Ji Won Kim;Jeong Sup Lee
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.732-737
    • /
    • 2023
  • A high-power Yb-doped femtosecond (fs) fiber laser at a repetition rate of 1.83 GHz is reported. By employing a 5-stage repetition rate multiplier, the repetition rate of the mode-locked master oscillator was multiplied from 57.1 MHz to 1.83 GHz. The ultrashort pulse output at 1.83 GHz was amplified in a two-stage Yb-doped fiber amplifier, leading to >100 W of fs laser output with a pulse duration of 290 fs. The theoretical pulse width along the fiber was simulated, showing that it was in good agreement with experimental results. Further improvement in power scaling is discussed.

Low voltage Low power OTAs using bulk driven in 0.35㎛ CMOS Process (0.35㎛ CMOS 공정에서 벌크 입력을 사용한 저전압 저전력 OTAs)

  • Kang, Seong-Ki;Jung, Min-Kyun;Han, Dae-Deok;Yang, Min-Jae;Yoon, Eun-Jung;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.451-454
    • /
    • 2015
  • This paper introduces 3 type of OTAs with $0.35-{\mu}m$ standard CMOS technology for Low-Power, Low-Voltage. The first type is a two-stage OTA designed to operate with a 1-V VDD and it has $1.774{\mu}W$ low power consumption. All transistors are operating in strong inversion. It takes Gm-Enhancement techniques to compensate gm, which is lowered by Bulk-Driven technique and has an Wide swing current mirror for low voltage operation and a Class-A output. The second type is a Two-stage OTA designed to operate with a 0.8-V VDD and It has 52nW low power consumption and 112dB high gain. The current mirror uses Composite Transistor binding Gates of two MOSFET to raise Rout which is similar with cascode structure. The third type is a Two-stage OTA designed to operate with a 0.6-V VDD and It has 160nW low power consumption and 72dB high gain. It takes Level Shift technique by Common Gate structure to amplify signals without additional bias voltage at second stage.

  • PDF

Series Resonant Full Bridge Inverter for Battery-fed Microwave Oven (배터리 구동 전자레인지를 위한 직렬 공진형 풀브릿지 인버터)

  • 鄭 龍 采;韓 盛 軫
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.165-170
    • /
    • 2002
  • In order to solve the problem of system efficiency reduced on account of two stage power conversion, we propose a series resonant full bridge Inverter circuit for battery-fed microwave oven. This circuit has both a compact size and a light weight comparing with the conventional HVT(High Voltage Transformer) method. Also, it may be adjusted power levels of the microwave oven by a frequency control. In this paper, operational principles are explained in detail in order to understand the circuit operation. Also, a proto-type Inverter circuit with 1[kW] Power consumption is built and tested for verifying the operation.

Applying Multi-Agent System for Optimal Multi-Microgrids Operation (멀티 마이크로그리드 최적 운영을 위한 멀티 에이전트 시스템 적용)

  • Bui, Van-Hai;Hussain, Akhtar;Kim, Hak-Man
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.464-465
    • /
    • 2016
  • This paper analyzes the capabilities of multi-agent system (MAS) technology for the optimal multi-microgrids (MMGs) operation in grid-connected mode. In this system, communication among microgrids (MGs) is realized by developing a modified contract net protocol (MCNP) based on agent communication language (ACL) messages. Moreover, a two-stage mathematical model is proposed based on mixed integer linear programming (MILP) for local optimization in each MG, and global optimization in energy management system.

Wireless Parallel Operation of High Voltage DC Pourer Supply using Steady-state Estimation (정상상태 판별을 이용한 고전압전원장치의 Wireless 병렬운전)

  • 백주원;유동욱;손호섭;김장목
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.255-261
    • /
    • 2004
  • This paper presents an improved droop method which minimizes the voltage droop of a parallel-connected power supply Conventionally, the droop method has been used to achieve a simple structure and no-interconnections among power sources. However, it has a trade-off between output voltage regulation and load sharing accuracy In this paper, the droop is minimized with a current and droop gain control using steady-stage estimation. The proposed method can achieve both good voltage regulation and good load sharing. A design example of two 10㎸, 100㎃ parallel modules is made and tested to verify the proposed current-sharing method.

A Study on the Optimum Allocation Model for Inventory Capacity (재고설비규모를 위한 최적분배 모델의 연구)

  • 최진영;정기호
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.5 no.6
    • /
    • pp.1-6
    • /
    • 1982
  • The objective of this thesis to Provide a better insight into the effect of the amount of in-process storage has on the efficiency of production line with variable operation times. It is assumed that the material enters the line at the first work station and is then processed progressively through the line until it exits at the last work station, a finite amount of in-process storage is provided before all but the first work station of the line and the operation time of the work stations are statistically independent and follow exponential distribution. Under the above assumption, optimum allocation model is developed and following two approaches are used : 1) Given the available storage capacity, optimum allocation which minimizes the number of items in the line. 2) Given the available storage capacity, optimum allocation which. maximizes the utilization factor of the line. In a balanced three stage line, the production line efficiency is maximized under both categories when the second in-process storage is larger than the first.

  • PDF