• 제목/요약/키워드: Two stage operation

검색결과 571건 처리시간 0.03초

A Two-stage Stochastic Programming Model for Optimal Reactive Power Dispatch with High Penetration Level of Wind Generation

  • Cui, Wei;Yan, Wei;Lee, Wei-Jen;Zhao, Xia;Ren, Zhouyang;Wang, Cong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.53-63
    • /
    • 2017
  • The increasing of wind power penetration level presents challenges in classical optimal reactive power dispatch (ORPD) which is usually formulated as a deterministic optimization problem. This paper proposes a two-stage stochastic programming model for ORPD by considering the uncertainties of wind speed and load in a specified time interval. To avoid the excessive operation, the schedule of compensators will be determined in the first-stage while accounting for the costs of adjusting the compensators (CACs). Under uncertainty effects, on-load tap changer (OLTC) and generator in the second-stage will compensate the mismatch caused by the first-stage decision. The objective of the proposed model is to minimize the sum of CACs and the expected energy loss. The stochastic behavior is formulated by three-point estimate method (TPEM) to convert the stochastic programming into equivalent deterministic problem. A hybrid Genetic Algorithm-Interior Point Method is utilized to solve this large-scale mixed-integer nonlinear stochastic problem. Two case studies on IEEE 14-bus and IEEE 118-bus system are provided to illustrate the effectiveness of the proposed method.

Production of Tropane Alkaloids by Two-stage Culture of Scopolia parviflora Nakai Adventitious Root

  • Kim, Won-Jung;Jung, Hee-Young;Min, Ji-Yun;Chung, Young-Gwan;Lee, Cheol-Ho;Choi, Myung-Suk
    • 한국약용작물학회지
    • /
    • 제12권5호
    • /
    • pp.372-377
    • /
    • 2004
  • Scopolia parviflora Nakai, a rare and endangered species, is the sole plant producing tropane alkaloids (TA) among the Korean native species. In order to enhance TA productivity the SP72 root line was selected by screening 100 of root line, and the optimal culture media for root growth and TA production were investigated with the SP72 roots. Based on the several media, SH and 2B5 medium were determined as growth medium and White and NN medium as production medium. Among the four combinations of two-stage culture, 2BN (2B5 as growth medium plus NN as production medium) showed more enhanced root growth and TA production as compared with production media of White and NN medium and growth media of SH and 2B5 medium, respectively. However, bubble column bioreactor (BCB) cultures applying two-stage culture did not reveal the effective results despite of the each successful operation of two-stage culture in conical flasks and BCB cultures.

스크류 열펌프 시스템의 운전제어 방안에 관한 연구 (A Study on the Operating Control of a Heat Pump System with Screw Compressors)

  • 박준택;이영수;김지영;채규정;양희정
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.168-172
    • /
    • 2013
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump system, which will be used for district heating and cooling. In this study, two issues of the system operating control were investigated. The first issue is the mode switching control from 1-stage to 2-stage. A stable 2-stage heating operation is guaranteed, only if the load-side water inlet temperature is over a certain value, where the 1-stage heating operation should be done first from a cold start. The second issue is oil level control. An oil shortage problem in the low stage compressor, which depends on the degree of suction superheat, was solved by a proper oil level control scheme.

척수 신경초종을 동반한 결핵성 척추염 1례 - 증례보고 - (A Case of Tuberculous Spondylitis Combined with Schwannoma of Spinal Cord - A Case Report -)

  • 박종훈;김규홍;이운기;최정훈;이인창;배상도
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1241-1244
    • /
    • 2001
  • The authors report a very rare case of tuberculous spondylitis combined with a schwannoma of spinal cord. A 39- year-old man was admitted because of paraparesis(G1/G2). MRI showed severe cord compression at two different levels. One was by the bulged soft tissue and subligamentous abscess extending from T7 to T9 and the other was by an intradural extramedullary cord tumor at the level of T1-2. At first operation, T8 corpectomy and T7-9 plate fixation with autogenous iliac bone graft were performed. After then, Paraparesis was improved(G2/G3) postoperatively. The second operation underwent two weeks later. The tumor was totally removed and shortly after second operation, paraparesis was markedly improved(G3/G4). Histological diagnosis were tuberculous spondylitis and schwannoma, respectively. The authors reviewed this case where good surgical outcome was obtained by two stage operation.

  • PDF

Major Aorto-pulmonary Collateral Artery 를 동반한 폐동맥 형성부전 및 심실중격결손의 외과적 수술요법 (Unifocalization and Complete Repair of Pulmonary Atresia and Ventricular Septal Defect with Major Aortopulmonary Collateral Arteries)

  • 이정상
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1191-1203
    • /
    • 1990
  • Pulmonary atresia and ventricular septal defect with major aortopulmonary collateral arteries [abbreviated as PA+VSD+MAPCA in the following] has limited the success of attempts at accurate diagnosis and complete surgical repair. From April 1986 to September 1990, 23 patients with PA+VSD+MAPCA among 96 patients of PA+VSD in Seoul National University Children’s Hospital were encountered. The group comprised 14 male and 9 female patients with ages ranging from 17 days to 177 months [mean 49.6 months]. We operated one stage total repair on good pulmonary artery sized two patients by R.E.V. [Reparation a l’etage ventriculaire] and Rastelli operation respectively. And the 11 patients who had independent MAPCAs and hypoplastic central pulmonary artery were dealt with unifocalization and modified Blalock-Taussig Shunt and followed by second stage repair in 3 patients later. We successfully had managed 7 patients whose MAPCAs could be ligated with modified Blalock-Taussig Shunt and followed by second stage repair in 3 patients with R.E.V or Rastelli operation. Recently, three obstruction after 11 unifocalization procedures made us to try palliative right ventricle-pulmonary artery conduit operation by Gore-Tex vascular graft interposition under cardiopulmonary bypass. And so we managed another 3 patients with these procedures for the purpose of pulmonary artery growth whose central pulmonary artery were severely hypoplastic. We experienced one death after second stage repair whose central pulmonary artery was created by 12mm Gore-Tex vascular graft and was unifocalized.

  • PDF

단일전력단 Two-Switch Forward 컨버터에 관한 연구 (A Study on the Single-Stage Two-Switch Forward Converter)

  • 배진용;김용
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.60-66
    • /
    • 2005
  • 본 연구에서는 단일전력단 Two-Switch Forward 컨버터에 관하여 논하였다. 최근 국제적으로 제정된 ICE 61000-3-2와 IEEE 519같은 규정에서 입력 전류에 대한 고조파 규제가 강화되면서 전원 공급 장치의 역률개선 회로가 필수적으로 되었다. 따라서 본 연구에서는 저전압 대전류 출력에 적합한 방안으로 단일전력단 Two-Switch Forward 컨버터 회로를 제안하고, 모드별 동작, 특성 및 설계에 관하여 논하였으며, MOSFET를 사용하여 200[W](5[V], 40[A])급 시작품을 제작, 100[kHz]에서 실험하였다.

단일전력단 고역률 Two-Switch Forward 컨버터 (Single-Stage High Power Factor Two-Switch Forward Converter)

  • 배진용;김용;조규만;이은영;이규훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.247-250
    • /
    • 2006
  • This paper presents the single-stage High Power Factor TSFC(Two-Switch Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

단일전력단 고역률 AC/DC Two-Switch Forward 컨버터 (Single-Stage High Power Factor AC/DC Two-Switch Forward Converter)

  • 배진용;김용;권순도;이규훈;계상범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.169-172
    • /
    • 2006
  • This paper presents the single-stage High Power Factor AC/DC Two-Switch Forward Converter (TSFC). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the simulation with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

A Novel Push-Pull Type Charge Pump Based on Voltage Doubler for LCD Drivers

  • Choi, Sung-Wook;Kwack, Kae-Dal
    • Journal of Information Display
    • /
    • 제9권2호
    • /
    • pp.9-13
    • /
    • 2008
  • A novel push-pull voltage converter structure, using a switched capacitor type voltage doubler, is proposed. The circuit is constructed with a two-stage push-pull voltage doubler that has a stable operation with small output ripple. The two-stage voltage doubler creates the output voltage 4Vdd. The high clock signal is cross-coupled to the input of the second stage with the opposite phase to reduce two switching transistors and capacitors. Simulation results verify that even with a reduced number of transistor and capacitor, there is no circuit performance loss. Adding one capacitor and two switching transistors the circuit can be changed to eight times of Vdd maker.

고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구 (A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans)

  • 조진수;한철희;조이상
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.