• 제목/요약/키워드: Two parameter on-off control

검색결과 24건 처리시간 0.023초

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

바닥 난방공간의 다인자 제어에 관한 실험적 연구 (An experimental study on the multiple parameter switching control for floor heating system)

  • 조성환;태춘섭;장철용
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

바닥복사 난방공간의 효율적인 난방제어방법 (The Effective Heating Control Method of the Radiant Floor Heating System)

  • 조성환;태춘섭
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

ATM망에서의 효율적인 UPC 알고리즘의 성능 개선 (The Performance Improvement of an Efficient Usage Parameter Control Algorithm in ATM Networks)

  • 박성곤
    • 한국정보처리학회논문지
    • /
    • 제4권12호
    • /
    • pp.3150-3158
    • /
    • 1997
  • ATM망에서 트래픽 제어는 서비스 질을 향상시키기 위한 방법으로 폭주가 일어난 후에 처리하는 반응 제어와 폭주가 발생하기 전에 처리하는 예방 제어의 2가지 방법이 있다. 특히 예방 제어의 방법은 연결 수락 제어, 사용 매개변수 제어, 망 매개변수 제어, 우선 순위 제어가 있다. 본 논문에서는 리키 버켓 기법에 점핑 윈도우 기법을 복합한 이중구조로 설계된 효율적인 사용 매개변수 제어 알고리즘을 제안한다. 제안 알고리즘은 먼저 리키 버켓를 사용하여 최대비트율을 제어하고, 점핑 윈도우를 사용하여 평균비트율의 위반여부를 판단하여 트래픽 제어를 한다. 제안된 알고리즘의 성능평가를 위하여 On/Off 트래픽 소스 모델을 가정하고 시뮬레이션 한 결과 기존 리키 버켓 기법보다 셀 손실률의 저하를 보였고, 버켓 크기도 감소시킬 수 있었다.

  • PDF

실시간 시뮬레이터를 이용한 AVR의 파라미터 튜닝에 관한 연구 (A Study on an AVR Parameter Tuning Method using Real-lime Simulator)

  • 김중문;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.69-75
    • /
    • 2002
  • AVR parameter tuning for voltage control of power system generators has generally been performed with the analytic methods and the simulation methods, which mostly depend on off-line linear mathematical models of excitation control system. However, due to the nonlinear nature of excitation control system, excitation control system performance of the tuned Parameters using the above conventional tuning methods may not be appropriate for some operating conditions. This paper presents an AVR parameter tuning method using actual on-line data of the excitation control system with the parameter optimization technique. As this method utilizes on-line operating data of the target excitation control system not the mathematical model of the system, it can overcome the limitation of model uncertainty Problems in conventional method, and it can tune the AVR parameter set which gives desired performance at the operating conditions. For the verification of proposed tuning method, two case studies with scaled excitation systems and the real-time power system simulator are presented.

새로운 섭동 추정기를 갖는 슬라이딩 모드 제어기의 설계 (Design of Sliding Mode Controller with New Perturbation Estimator)

  • 함준호;최승복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.782-787
    • /
    • 2004
  • In the conventional sliding mode control technique, a priori knowledge of the bound of external disturbances or/and parameter uncertainties is required to assure control robustness. This, however, may not be easy to obtain in practical situation. This work presents a novel methodology, a sliding mode controller with perturbation estimator, which offers a robust control performance without a priori knowledge about the perturbations (disturbances and parameter uncertainties). The proposed technique is featured by an integrated average value of the imposed perturbation over a certain sampling period. This work also proposes two effective actuating methods of the perturbation estimator: on-off condition and filtering condition. In order to demonstrate the effectiveness of the proposed methodology, a two-link robotic system is adopted and its position control performance is evaluated. In addition, a comparative work between the conventional technique and the proposed one is undertaken.

  • PDF

고속전자밸브를 사용한 유압시스템의 안정성 해석에 관한 연구 (A Study on Stability Analysis of Hydraulic System Using High Speed On-Off Valves)

  • 유태재
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.412-420
    • /
    • 2003
  • This study describes the merits of PWM control of hydraulic system using high speed on-off valves. Generally, Electro-hydraulic valves can be classified into two classification: valves which are controlled by analog signal and which are controlled by digital. The former includes hydraulic servo valves and proportional valves which require A/D converters as interface to digital computer and too costly and sensitive to oil contamination because of complexity in structures. The latter includes high speed on-off valves which do not require A/D converters because they are normally operated in a pulse width modulation(PWM) method, and are low in price and robust to oil contamination because of their simple structures. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using 2/2way high speed on-off valves and to give a criterion for the stability of this system. The nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are simulated.

Control of Short-Channel Effects in Nano DG MOSFET Using Gaussian-Channel Doping Profile

  • Charmi, Morteza
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권5호
    • /
    • pp.270-274
    • /
    • 2016
  • This article investigates the use of the Gaussian-channel doping profile for the control of the short-channel effects in the double-gate MOSFET whereby a two-dimensional (2D) quantum simulation was used. The simulations were completed through a self-consistent solving of the 2D Poisson equation and the Schrodinger equation within the non-equilibrium Green’s function (NEGF) formalism. The impacts of the p-type-channel Gaussian-doping profile parameters such as the peak doping concentration and the straggle parameter were studied in terms of the drain current, on-current, off-current, sub-threshold swing (SS), and drain-induced barrier lowering (DIBL). The simulation results show that the short-channel effects were improved in correspondence with incremental changes of the straggle parameter and the peak doping concentration.

컴퓨터 수치제어 선반에서의 진원통도 보상제어 (Compensatory cylindricity control of the C.N.C. turing process)

  • 강민식;이종원
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.694-704
    • /
    • 1988
  • 본 연구에서는 현장에서 흔히 수행되는 가공 후(post-process) 측정만을 이용 한 단일절삭(single-pass)으로써 공작물이 원하는 일정한 직경을 유지할 수 있다는 것 을 실험을 통해 검증해 보이고자 한다. 이와 같은 방식은 이미 보오링 작업 중 보오 링바의 노출 길이 변화에 따른 가공면의 내경 오차를 없애주기 위한 방법으로써 제시 된 바 있다. 즉 반복 최소 자승법(recursive least squares)으로 미리 가정된 절삭 조건과 공작물 처짐 사이의 관계식과 관련된 계수를 가공 후에 가공 공작물의 표면 측 정으로 매 번보정(update)시켜 줌으로써 일정 직경을 얻기위한 절삭조건을 결정하고자 한다.

Vibration control of a time-varying modal-parameter footbridge: study of semi-active implementable strategies

  • Soria, Jose M.;Diaz, Ivan M.;Garcia-Palacios, Jaime H.
    • Smart Structures and Systems
    • /
    • 제20권5호
    • /
    • pp.525-537
    • /
    • 2017
  • This paper explores different vibration control strategies for the cancellation of human-induced vibration on a structure with time-varying modal parameters. The main motivation of this study is a lively urban stress-ribbon footbridge (Pedro $G\acute{o}mez$ Bosque, Valladolid, Spain) that, after a whole-year monitoring, several natural frequencies within the band of interest (normal paring frequency range) have been tracked. The most perceptible vibration mode of the structure at approximately 1.8 Hz changes up to 20%. In order to find a solution for this real case, this paper takes the annual modal parameter estimates (approx. 14000 estimations) of this mode and designs three control strategies: a) a tuned mass damper (TMD) tuned to the most-repeated modal properties of the aforementioned mode, b) two semi-active TMD strategies, one with an on-off control law for the TMD damping, and other with frequency and damping tuned by updating the damper force. All strategies have been carefully compared considering two structure models: a) only the aforementioned mode and b) all the other tracked modes. The results have been compared considering human-induced vibrations and have helped the authors on making a decision of the most advisable strategy to be practically implemented.